mirror of
https://github.com/cloud-hypervisor/cloud-hypervisor.git
synced 2024-12-22 21:55:20 +00:00
vmm: cpu: Add the CpuManager onto the IO bus
This allows the kernel (via ACPI based controls) to query and control the CPU state. Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This commit is contained in:
parent
39a1b8f4db
commit
1da0ff395d
@ -11,7 +11,7 @@
|
||||
|
||||
use std::os::unix::thread::JoinHandleExt;
|
||||
use std::sync::atomic::{AtomicBool, Ordering};
|
||||
use std::sync::{Arc, Barrier, Mutex, RwLock};
|
||||
use std::sync::{Arc, Barrier, Mutex, RwLock, Weak};
|
||||
use std::thread;
|
||||
use std::{fmt, io, result};
|
||||
|
||||
@ -19,7 +19,7 @@ use libc::{c_void, siginfo_t};
|
||||
|
||||
use crate::device_manager::DeviceManager;
|
||||
|
||||
use devices::ioapic;
|
||||
use devices::{ioapic, BusDevice};
|
||||
use kvm_ioctls::*;
|
||||
|
||||
use vm_memory::{Address, GuestAddress, GuestMemoryMmap};
|
||||
@ -110,6 +110,9 @@ pub enum Error {
|
||||
|
||||
/// Failed to join on vCPU threads
|
||||
ThreadCleanup,
|
||||
|
||||
/// Cannot add legacy device to Bus.
|
||||
BusError(devices::BusError),
|
||||
}
|
||||
pub type Result<T> = result::Result<T, Error>;
|
||||
|
||||
@ -329,7 +332,7 @@ impl Vcpu {
|
||||
|
||||
pub struct CpuManager {
|
||||
boot_vcpus: u8,
|
||||
io_bus: Arc<devices::Bus>,
|
||||
io_bus: Weak<devices::Bus>,
|
||||
mmio_bus: Arc<devices::Bus>,
|
||||
ioapic: Option<Arc<Mutex<ioapic::Ioapic>>>,
|
||||
vm_memory: Arc<RwLock<GuestMemoryMmap>>,
|
||||
@ -341,6 +344,12 @@ pub struct CpuManager {
|
||||
threads: Vec<thread::JoinHandle<()>>,
|
||||
}
|
||||
|
||||
impl BusDevice for CpuManager {
|
||||
fn read(&mut self, _base: u64, _offset: u64, data: &mut [u8]) {}
|
||||
|
||||
fn write(&mut self, _base: u64, _offset: u64, data: &[u8]) {}
|
||||
}
|
||||
|
||||
impl CpuManager {
|
||||
pub fn new(
|
||||
boot_vcpus: u8,
|
||||
@ -349,10 +358,10 @@ impl CpuManager {
|
||||
fd: Arc<VmFd>,
|
||||
cpuid: CpuId,
|
||||
reset_evt: EventFd,
|
||||
) -> Arc<Mutex<CpuManager>> {
|
||||
) -> Result<Arc<Mutex<CpuManager>>> {
|
||||
let cpu_manager = Arc::new(Mutex::new(CpuManager {
|
||||
boot_vcpus,
|
||||
io_bus: device_manager.io_bus().clone(),
|
||||
io_bus: Arc::downgrade(&device_manager.io_bus().clone()),
|
||||
mmio_bus: device_manager.mmio_bus().clone(),
|
||||
ioapic: device_manager.ioapic().clone(),
|
||||
vm_memory: guest_memory,
|
||||
@ -365,6 +374,15 @@ impl CpuManager {
|
||||
}));
|
||||
|
||||
cpu_manager
|
||||
.lock()
|
||||
.unwrap()
|
||||
.io_bus
|
||||
.upgrade()
|
||||
.unwrap()
|
||||
.insert(cpu_manager.clone(), 0x0cd8, 0xc)
|
||||
.map_err(Error::BusError)?;
|
||||
|
||||
Ok(cpu_manager)
|
||||
}
|
||||
|
||||
// Starts all the vCPUs that the VM is booting with. Blocks until all vCPUs are running.
|
||||
@ -383,7 +401,7 @@ impl CpuManager {
|
||||
let mut vcpu = Vcpu::new(
|
||||
cpu_id,
|
||||
&self.fd,
|
||||
self.io_bus.clone(),
|
||||
self.io_bus.clone().upgrade().unwrap(),
|
||||
self.mmio_bus.clone(),
|
||||
ioapic,
|
||||
creation_ts,
|
||||
|
@ -428,7 +428,8 @@ impl Vm {
|
||||
fd,
|
||||
cpuid,
|
||||
reset_evt,
|
||||
);
|
||||
)
|
||||
.map_err(Error::CpuManager)?;
|
||||
|
||||
Ok(Vm {
|
||||
kernel,
|
||||
|
Loading…
Reference in New Issue