mirror of
https://github.com/cloud-hypervisor/cloud-hypervisor.git
synced 2024-12-22 13:45:20 +00:00
tests: Use a disk image for test_vfio rather than virtio-fs
This reduces the complexity of the test slightly. The PCI BDFs in the L1 needed changing as the block devices come before the network ones. Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This commit is contained in:
parent
8fbc4b4004
commit
4ef702ea76
@ -160,7 +160,8 @@ if [ ! -d "$SHARED_DIR" ]; then
|
||||
fi
|
||||
|
||||
VFIO_DIR="$WORKLOADS_DIR/vfio"
|
||||
rm -rf $VFIO_DIR
|
||||
VFIO_DISK_IMAGE="$WORKLOADS_DIR/vfio.img"
|
||||
rm -rf $VFIO_DIR $VFIO_DISK_IMAGE
|
||||
mkdir -p $VFIO_DIR
|
||||
cp $FOCAL_OS_IMAGE $VFIO_DIR
|
||||
cp $FW $VFIO_DIR
|
||||
|
@ -30,12 +30,12 @@ write_files:
|
||||
content: |
|
||||
#!/bin/bash
|
||||
|
||||
mount -t virtiofs -o dax myfs /mnt
|
||||
bash -c "echo 0000:00:05.0 > /sys/bus/pci/devices/0000\:00\:05.0/driver/unbind"
|
||||
bash -c "echo 1af4 1041 > /sys/bus/pci/drivers/vfio-pci/new_id"
|
||||
mount /dev/vdc /mnt
|
||||
bash -c "echo 0000:00:06.0 > /sys/bus/pci/devices/0000\:00\:06.0/driver/unbind"
|
||||
bash -c "echo 1af4 1041 > /sys/bus/pci/drivers/vfio-pci/new_id"
|
||||
bash -c "echo 0000:00:07.0 > /sys/bus/pci/devices/0000\:00\:07.0/driver/unbind"
|
||||
bash -c "echo 1af4 1041 > /sys/bus/pci/drivers/vfio-pci/new_id"
|
||||
# 1G ram requires 512 pages
|
||||
echo 512 | sudo tee /proc/sys/vm/nr_hugepages
|
||||
sudo chmod a+rwX /dev/hugepages
|
||||
/mnt/cloud-hypervisor --kernel /mnt/vmlinux --cmdline "console=hvc0 reboot=k panic=1 nomodules i8042.noaux i8042.nomux i8042.nopnp i8042.dumbkbd root=/dev/vda1 VFIOTAG" --disk path=/mnt/focal-server-cloudimg-amd64-custom.qcow2 path=/mnt/cloudinit.img --cpus boot=1 --memory size=512M,hotplug_size=1G,file=/dev/hugepages --device path=/sys/bus/pci/devices/0000:00:05.0/ path=/sys/bus/pci/devices/0000:00:06.0/ --api-socket /tmp/ch_api.sock
|
||||
/mnt/cloud-hypervisor --kernel /mnt/vmlinux --cmdline "console=hvc0 reboot=k panic=1 nomodules i8042.noaux i8042.nomux i8042.nopnp i8042.dumbkbd root=/dev/vda1 VFIOTAG" --disk path=/mnt/focal-server-cloudimg-amd64-custom.qcow2 path=/mnt/cloudinit.img --cpus boot=1 --memory size=512M,hotplug_size=1G,file=/dev/hugepages --device path=/sys/bus/pci/devices/0000:00:06.0/ path=/sys/bus/pci/devices/0000:00:07.0/ --api-socket /tmp/ch_api.sock
|
||||
|
@ -3247,7 +3247,7 @@ mod tests {
|
||||
let mut kernel_path = workload_path.clone();
|
||||
kernel_path.push("bzImage");
|
||||
|
||||
let mut vfio_path = workload_path;
|
||||
let mut vfio_path = workload_path.clone();
|
||||
vfio_path.push("vfio");
|
||||
|
||||
let mut cloud_init_vfio_base_path = vfio_path.clone();
|
||||
@ -3261,19 +3261,45 @@ mod tests {
|
||||
)
|
||||
.expect("copying of cloud-init disk failed");
|
||||
|
||||
let mut vfio_disk_path = workload_path;
|
||||
vfio_disk_path.push("vfio.img");
|
||||
|
||||
// Create the vfio disk image
|
||||
let output = Command::new("mkfs.ext4")
|
||||
.arg("-d")
|
||||
.arg(vfio_path.to_str().unwrap())
|
||||
.arg(vfio_disk_path.to_str().unwrap())
|
||||
.arg("2g")
|
||||
.output()
|
||||
.unwrap();
|
||||
if !output.status.success() {
|
||||
eprintln!("{}", String::from_utf8_lossy(&output.stderr));
|
||||
panic!("mkfs.ext4 command generated an error");
|
||||
}
|
||||
|
||||
let vfio_tap0 = "vfio-tap0";
|
||||
let vfio_tap1 = "vfio-tap1";
|
||||
let vfio_tap2 = "vfio-tap2";
|
||||
let vfio_tap3 = "vfio-tap3";
|
||||
|
||||
let (mut daemon_child, virtiofsd_socket_path) =
|
||||
prepare_virtiofsd(&guest.tmp_dir, vfio_path.to_str().unwrap(), "none");
|
||||
|
||||
let mut child = GuestCommand::new(&guest)
|
||||
.args(&["--cpus", "boot=4"])
|
||||
.args(&["--memory", "size=2G,hugepages=on,shared=on"])
|
||||
.args(&["--kernel", kernel_path.to_str().unwrap()])
|
||||
.default_disks()
|
||||
.args(&[
|
||||
"--disk",
|
||||
format!(
|
||||
"path={}",
|
||||
guest.disk_config.disk(DiskType::OperatingSystem).unwrap()
|
||||
)
|
||||
.as_str(),
|
||||
format!(
|
||||
"path={}",
|
||||
guest.disk_config.disk(DiskType::CloudInit).unwrap()
|
||||
)
|
||||
.as_str(),
|
||||
format!("path={}", vfio_disk_path.to_str().unwrap()).as_str(),
|
||||
])
|
||||
.args(&[
|
||||
"--cmdline",
|
||||
format!(
|
||||
@ -3301,14 +3327,6 @@ mod tests {
|
||||
)
|
||||
.as_str(),
|
||||
])
|
||||
.args(&[
|
||||
"--fs",
|
||||
format!(
|
||||
"tag=myfs,socket={},num_queues=1,queue_size=1024,dax=on",
|
||||
virtiofsd_socket_path,
|
||||
)
|
||||
.as_str(),
|
||||
])
|
||||
.spawn()
|
||||
.unwrap();
|
||||
|
||||
@ -3360,7 +3378,7 @@ mod tests {
|
||||
|
||||
// Hotplug an extra virtio-net device through L2 VM.
|
||||
guest.ssh_command_l1(
|
||||
"echo 0000:00:07.0 | sudo tee /sys/bus/pci/devices/0000:00:07.0/driver/unbind",
|
||||
"echo 0000:00:08.0 | sudo tee /sys/bus/pci/devices/0000:00:08.0/driver/unbind",
|
||||
)?;
|
||||
guest.ssh_command_l1(
|
||||
"echo 1af4 1041 | sudo tee /sys/bus/pci/drivers/vfio-pci/new_id",
|
||||
@ -3368,7 +3386,7 @@ mod tests {
|
||||
let vfio_hotplug_output = guest.ssh_command_l1(
|
||||
"sudo /mnt/ch-remote \
|
||||
--api-socket=/tmp/ch_api.sock \
|
||||
add-device path=/sys/bus/pci/devices/0000:00:07.0,id=vfio123",
|
||||
add-device path=/sys/bus/pci/devices/0000:00:08.0,id=vfio123",
|
||||
)?;
|
||||
aver!(
|
||||
tb,
|
||||
@ -3450,9 +3468,7 @@ mod tests {
|
||||
);
|
||||
|
||||
let _ = child.kill();
|
||||
let _ = daemon_child.kill();
|
||||
let _ = child.wait();
|
||||
let _ = daemon_child.wait();
|
||||
|
||||
Ok(())
|
||||
});
|
||||
|
Loading…
Reference in New Issue
Block a user