Commit Graph

244 Commits

Author SHA1 Message Date
Rob Bradford
ffd816ebfa main, vmm: Remove deprecated --vhost-user-blk
This has been superseded by using --disk with vhost_user=true and
socket=<socket>

Fixes: #678

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-24 07:26:31 +01:00
Sergio Lopez
5c06b7f862 vhost_user_block: Implement optional static polling
Actively polling the virtqueue significantly reduces the latency of
each I/O operation, at the expense of using more CPU time. This
features is specially useful when using low-latency devices (SSD,
NVMe) as the backend.

This change implements static polling. When a request arrives after
being idle, vhost_user_block will keep checking the virtqueue for new
requests, until POLL_QUEUE_US (50us) has passed without finding one.

POLL_QUEUE_US is defined to be 50us, based on the current latency of
enterprise SSDs (< 30us) and the overhead of the emulation.

This feature is enabled by default, and can be disabled by using the
"poll_queue" parameter of "block-backend".

This is a test using null_blk as a backend for the image, with the
following parameters:

 - null_blk gb=20 nr_devices=1 irqmode=2 completion_nsec=0 no_sched=1

With "poll_queue=false":

fio --ioengine=sync --bs=4k --rw randread --name randread --direct=1
--filename=/dev/vdb --time_based --runtime=10

randread: (g=0): rw=randread, bs=(R) 4096B-4096B, (W) 4096B-4096B, (T) 4096B-4096B, ioengine=sync, iodepth=1
fio-3.14
Starting 1 process
Jobs: 1 (f=1): [r(1)][100.0%][r=169MiB/s][r=43.2k IOPS][eta 00m:00s]
randread: (groupid=0, jobs=1): err= 0: pid=433: Tue Feb 18 11:12:59 2020
  read: IOPS=43.2k, BW=169MiB/s (177MB/s)(1688MiB/10001msec)
    clat (usec): min=17, max=836, avg=21.64, stdev= 3.81
     lat (usec): min=17, max=836, avg=21.77, stdev= 3.81
    clat percentiles (nsec):
     |  1.00th=[19328],  5.00th=[19840], 10.00th=[20352], 20.00th=[21120],
     | 30.00th=[21376], 40.00th=[21376], 50.00th=[21376], 60.00th=[21632],
     | 70.00th=[21632], 80.00th=[21888], 90.00th=[22144], 95.00th=[22912],
     | 99.00th=[28544], 99.50th=[30336], 99.90th=[39168], 99.95th=[42752],
     | 99.99th=[71168]
   bw (  KiB/s): min=168440, max=188496, per=100.00%, avg=172912.00, stdev=3975.63, samples=19
   iops        : min=42110, max=47124, avg=43228.00, stdev=993.91, samples=19
  lat (usec)   : 20=5.90%, 50=94.08%, 100=0.02%, 250=0.01%, 500=0.01%
  lat (usec)   : 750=0.01%, 1000=0.01%
  cpu          : usr=10.35%, sys=25.82%, ctx=432417, majf=0, minf=10
  IO depths    : 1=100.0%, 2=0.0%, 4=0.0%, 8=0.0%, 16=0.0%, 32=0.0%, >=64=0.0%
     submit    : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
     complete  : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
     issued rwts: total=432220,0,0,0 short=0,0,0,0 dropped=0,0,0,0
     latency   : target=0, window=0, percentile=100.00%, depth=1

Run status group 0 (all jobs):
   READ: bw=169MiB/s (177MB/s), 169MiB/s-169MiB/s (177MB/s-177MB/s), io=1688MiB (1770MB), run=10001-10001msec

Disk stats (read/write):
  vdb: ios=427867/0, merge=0/0, ticks=7346/0, in_queue=0, util=99.04%

With "poll_queue=true" (default):

fio --ioengine=sync --bs=4k --rw randread --name randread --direct=1
--filename=/dev/vdb --time_based --runtime=10

randread: (g=0): rw=randread, bs=(R) 4096B-4096B, (W) 4096B-4096B, (T) 4096B-4096B, ioengine=sync, iodepth=1
fio-3.14
Starting 1 process
Jobs: 1 (f=1): [r(1)][100.0%][r=260MiB/s][r=66.7k IOPS][eta 00m:00s]
randread: (groupid=0, jobs=1): err= 0: pid=422: Tue Feb 18 11:14:47 2020
  read: IOPS=68.5k, BW=267MiB/s (280MB/s)(2674MiB/10001msec)
    clat (usec): min=10, max=966, avg=13.60, stdev= 3.49
     lat (usec): min=10, max=966, avg=13.70, stdev= 3.50
    clat percentiles (nsec):
     |  1.00th=[11200],  5.00th=[11968], 10.00th=[11968], 20.00th=[12224],
     | 30.00th=[12992], 40.00th=[13504], 50.00th=[13760], 60.00th=[13888],
     | 70.00th=[14016], 80.00th=[14144], 90.00th=[14272], 95.00th=[14656],
     | 99.00th=[20352], 99.50th=[23936], 99.90th=[35072], 99.95th=[36096],
     | 99.99th=[47872]
   bw (  KiB/s): min=265456, max=296456, per=100.00%, avg=274229.05, stdev=13048.14, samples=19
   iops        : min=66364, max=74114, avg=68557.26, stdev=3262.03, samples=19
  lat (usec)   : 20=98.84%, 50=1.15%, 100=0.01%, 250=0.01%, 500=0.01%
  lat (usec)   : 750=0.01%, 1000=0.01%
  cpu          : usr=8.24%, sys=21.15%, ctx=684669, majf=0, minf=10
  IO depths    : 1=100.0%, 2=0.0%, 4=0.0%, 8=0.0%, 16=0.0%, 32=0.0%, >=64=0.0%
     submit    : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
     complete  : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
     issued rwts: total=684611,0,0,0 short=0,0,0,0 dropped=0,0,0,0
     latency   : target=0, window=0, percentile=100.00%, depth=1

Run status group 0 (all jobs):
   READ: bw=267MiB/s (280MB/s), 267MiB/s-267MiB/s (280MB/s-280MB/s), io=2674MiB (2804MB), run=10001-10001msec

Disk stats (read/write):
  vdb: ios=677855/0, merge=0/0, ticks=7026/0, in_queue=0, util=99.04%

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-02-19 17:13:47 +00:00
Sebastien Boeuf
ddf6caf955 ci: Improve test_memory_mergeable_on stability
The integration test test_memory_mergeable_on has been fairly unstable
for quite some time now. Because it can take some time for the VM to be
spawned and to be able to perform a correct measure of the PSS, this
commit simply increases the time before such measure is done.
This should return more accurate PSS results, which should help
stabilize the test.

Fixes #781

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-02-19 12:36:28 +00:00
Liu Bo
4970e2f703 vhost-user-fs: add dax tests for vhost_user_fs rust daemon
Now that vhost_user_fs rust daemon supports virtiofs's dax mode, this adds
the two dax tests accordingly.

Signed-off-by: Liu Bo <bo.liu@linux.alibaba.com>
2020-02-19 07:52:50 +00:00
Rob Bradford
f7378bc092 tests: Add self spawning vhost-user-block test
Also rename the net self spawning test to differentiate it from the the
block one.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-18 08:43:47 +00:00
Rob Bradford
7485a0c1f7 Revert "build: Don't fail build on test_vfio failure"
This reverts commit 014844d0da.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-17 08:23:02 +00:00
Rob Bradford
f03602a4c9 tests: Add self spawning vhost-user-net test
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-14 17:32:49 +00:00
Bo Chen
ebd83699dc main: Display git commit hash with the '--version' option
Add a build-script to propagate the git commit hash to other crates at
compile time through environment variables, and display the hash along
with the '--version' option.

Fixes #729

Signed-off-by: Bo Chen <chen.bo@intel.com>
2020-02-14 10:00:14 +01:00
Rob Bradford
e8e4f43d52 tests: Use hugepages for test_vfio
Using hugepages with VFIO and virtiofs can improve the performance of
the test_vfio test.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-13 17:55:21 +01:00
Rob Bradford
014844d0da build: Don't fail build on test_vfio failure
test_vfio has been failing consistently on the CI so mark it with
a "#[ignore]" and then forceably build it again but ignore the build
result.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-12 15:37:47 +00:00
Rob Bradford
6e6b2b84fe scripts: Check the Rust formatting is valid
Check the rust formatting rather than just reformatting code on the CI
agent.

Also fix a formatting error that slipped in whilst the cargo fmt check
was not working correctly.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-04 16:47:05 +01:00
Rob Bradford
bc053f1b13 main: Ignore error on log writing
A previous version of this change attempted to avoid panicking by not
using .expect() when handling an error when attempting to write to the
log file. Unfortunately the macro eprintln!() that was used to replace
the .expect() also has the behaviour of panicking if stderr cannot be
used. Instead swallow the error completely as if writing to the log has
failed at logging time it is almost certainly the case that any message
about the log would also not be seen.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-04 12:22:23 +00:00
Yang Zhong
91739be120 main: Add help info for block-backend
Since the vhost-user-blk binary will be removed and the newer
release will integrate this block backend into cloud-hypervisor
binary. The block backend code has been added num_queues cmdline
support, we need update multiple queues help info for this
block-backend in the cloud-hypervisor.

Signed-off-by: Yang Zhong <yang.zhong@intel.com>
2020-02-04 11:06:17 +00:00
Samuel Ortiz
ae6cf4c922 tests: integration: Add memory overhead test
We measure the memory overhead that the VMM process adds to the guest VM
and compare it with a maximum acceptable limit. The test is run against
a simple VM, running 1 vCPU and 512MB of RAM. Although this is not by
any mean a comprehensive VMM overhead measurement, it will allow us to
detect when and if any PR makes our code cross an arbitrary memory
overhead threshold.

Fixes: #64

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2020-02-04 09:23:56 +00:00
Rob Bradford
7cb61d3960 main: Don't panic (by calling .expect()) if writing to the log fails
As this can happen during the running of the VMM we should be very
careful not to panic() as that can lead to a thread being used by the VM
disappearing.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-03 19:08:08 +01:00
Yang Zhong
789a39a2d5 ci: Add MQ support in the test cases
The CI need to add MQ support, and the vcpu number should
be bigger than or equal to queue number.

Signed-off-by: Yang Zhong <yang.zhong@intel.com>
2020-02-03 09:49:27 +01:00
Rob Bradford
b4d04bdff6 tests: Add CLI <-> API validation test for --disk changes
Check that the CLI generates the JSON data as expected.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-29 08:06:37 +00:00
Rob Bradford
12f4cd951a tests: Use "--disks" for vhost-user-block testing
Use newly unified command line options for testing vhost-user based
block support.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-29 08:06:37 +00:00
Rob Bradford
aeeae661fc vmm: Support vhost-user-block via "--disks"
Add a socket and vhost_user parameter to this option so that the same
configuration option can be used for both virtio-block and
vhost-user-block.  For now it is necessary to specify both vhost_user
and socket parameters as auto activation is not yet implemented. The wce
parameter for supporting "Write Cache Enabling" is also added to the
disk configuration.

The original command line parameter is still supported for now and will
be removed in a future release.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-29 08:06:37 +00:00
Rob Bradford
4888dd2e01 tests: Add CLI <-> API validation test for --net changes
Check that the CLI generates the JSON data as expected.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-28 12:39:26 +00:00
Rob Bradford
8f096b8be5 tests: Use "--net" parameter for vhost-user-net setup
Use the newly unified parameter for setting up vhost-user-net based
networking.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-28 12:39:26 +00:00
Rob Bradford
a831aa214c vmm: Support vhost-user-net via "--net"
Add a socket and vhost_user parameter to this option so that the same
configuration option can be used for both virtio-net and vhost-user-net.
For now it is necessary to specify both vhost_user and socket parameters
as auto activation is not yet implemented. The original command line
parameter is still supported for now.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-28 12:39:26 +00:00
Sebastien Boeuf
9efaff73fa ci: Consolidate virtio-blk integration tests
In order to reduce the amount of times VMs are being started through
integration tests, this commit consolidates very similar tests related
to virtio-blk into a single one.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-28 09:26:53 +01:00
Sebastien Boeuf
a33e8342ee ci: Add integration test for virtio-blk multiqueue support
Just add a new integration test to verify that multiqueue support is
correctly supported and that we can find the right amount of queues in
the guest.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-28 09:26:53 +01:00
Sebastien Boeuf
08e47ebd4b vmm: Add num_queues and queue_size parameters to virtio-blk
The number of queues and the size of each queue were not configurable.
In anticipation for adding multiqueue support, this commit introduces
some new parameters to let the user decide about the number of queues
and the queue size.

Note that the default values for each of these parameters are identical
to the default values used for vhost-user-blk, that is 1 for the number
of queues and 128 for the queue size.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-28 09:26:53 +01:00
Sebastien Boeuf
aa5ae7616e src: Fix map_err losing the inner error
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-24 12:42:09 +01:00
Rob Bradford
cafab9e981 main: Add some command line argument conflicts
Add explicit exclusions with --net-backend from --block-backend (and
vice-versa.) And also with "--kernel" as this is the option for "VM boot" that is never optional.

Ideally we would conflcit the backend arguments against the "vm-group"
however this does not work as it includes some arguments that have a
default value set and thus clap thinks those arguments are always
provided. Conflicting with "--kernel" is thus a reasonable compromise.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
611d13ed1b main: Move logging arguments to their own group
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
8aabb9012d main: Add "--vhost-user-blk" to the "vm-config" group
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
bdb0ad98c4 tests: Use cloud-hypervisor binary for "--{net,block}-backend"
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
45fb9187c5 main: Allow main binary to be used as net or block backend
Use newly factorised out function to start the block or net
vhost-user-backend.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
b851887738 main: Split current VMM running code into it's own function
This prepaees the main binary to start running vhost-user backends.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
dd82064aba main: Delay converting command line to VM params
Generate the VM params until after the logging has been enabled. This
will make it possible to reuse the logging for vhost backends.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
e12179a3e6 bin: vhost_user_net: Rename "--backend" to "--net-backend"
This will prevent it from conflicting when it is aggregated into the
cloud-hypervisor binary.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Rob Bradford
3ede2dc53a bin: vhost_user_blk: Rename "--backend" to "--block-backend"
This will prevent it from conflicting when it is aggregated into the
cloud-hypervisor binary.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-23 10:30:06 +00:00
Sergio Lopez
605fa8307b ci: Add integration test for virtio-blk with 'direct=on'
Previous commit added 'direct' support for virtio-blk to be able to
open files backing disk images with O_DIRECT, so add an integration
test for this new feature.

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-01-21 13:39:45 +00:00
Sergio Lopez
2bd90d9263 ci: Add integration test for virtio-blk with 'readonly=on'
Previous commit added 'readonly' support for virtio-blk to be able to
configure read-only devices, so add an integration test for this new
feature.

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-01-21 13:39:45 +00:00
Sergio Lopez
ed5459f268 ci: Add integration test for vhost_user_blk with 'direct'
This test is a variant of test_boot_vhost_user_blk(), named
test_boot_vhost_user_blk_direct(), that instances the vhost-user-blk
daemon with 'direct=true', to test this recently introduced feature
for opening files with O_DIRECT.

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-01-17 17:28:44 +00:00
Cathy Zhang
973eb16ae9 src: Add multiple queue checking in vhost-user-net integration test
Update queue number with 4 to verify if vhost-user-net device
and backend could work well with multiple queue.

Signed-off-by: Cathy Zhang <cathy.zhang@intel.com>
2020-01-17 12:06:19 +01:00
Cathy Zhang
4885dc0ed4 src: Update test_valid_vm_config_net with new option for virtio-net
There are two new options num_queues and queue_size defined for
virtio-net, add them in test_valid_vm_config_net which is used
to validate that both the CLI and the OpenAPI will generate the
same configuration.

Signed-off-by: Cathy Zhang <cathy.zhang@intel.com>
2020-01-17 12:06:19 +01:00
Cathy Zhang
404316eea1 vmm: Add multiple queue option and update config for virtio-net device
Add num_queues and queue_size for virtio-net device to make them configurable,
while add the associated options in command line.

Update cloud-hypervisor.yaml with the new options for NetConfig.

Signed-off-by: Cathy Zhang <cathy.zhang@intel.com>
2020-01-17 12:06:19 +01:00
Rob Bradford
d2d1248342 tests: Add test combining memory and vCPU hotplug
Test resizing with both optional parameters set in the VmResize API
works.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-15 20:21:22 +01:00
Rob Bradford
2073007214 tests: Add integration test for RAM hotplug
Reuse the existing infrastructure for CPU hotplug and add a new test for
memory hotplug.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-15 20:21:22 +01:00
Rob Bradford
f5137e84bb vmm, main: Add optional "hotplug_size" to --mem
This specifies how much address space should be reserved for hotplugging
of RAM. This space is reserved by adding move the start of the device
area by the desired amount.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-15 20:21:22 +01:00
Sebastien Boeuf
f427d94422 virtio-fs: Update virtiofs daemon parameters
With the latest version of virtiofsd, some changes have been made
to the socket path parameter. This needs to be updated in the cloud
hypervisor codebase, so that our CI keeps running correctly.

Fixes #611

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-13 15:55:34 +00:00
Sebastien Boeuf
ad223f2b50 fs: Use cache=none by default
The cache= option from the virtiofsd backend is meant to be used
depending on how the user wants to use the guest page cache. For most
use cases, we want to bypass the guest page cache to reduce the guest
memory footprint, which is why "cache=none" should be the default.

"cache=always" is the other option when the user wants to do something
specific by using the guest page cache, but should not be the default
anymore.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-08 09:27:07 +01:00
Sebastien Boeuf
143471b739 fs: Update mount command to mount virtiofs filesystem
With latest kernel, virtio-fs mount command has been simplified, and
this needs to be applied everywhere in our tests and documentation.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-08 09:27:07 +01:00
Sebastien Boeuf
f668603694 ci: Fix flaky test_memory_mergeable_on test
Because we don't always reach the expected footprint improvements with
KSM, let's review the numbers. By reducing the expectations and
increasing the amount of pages to scan, this should stabilize the CI.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-20 13:44:22 +00:00
Rob Bradford
1e3fd2f6a5 tests: Remove many redundant clones
As found by updated clippy:

e.g:

error: redundant clone
    --> src/main.rs:1590:57
     |
1590 |             let mut osdisk_raw_base_path = workload_path.clone();
     |                                                         ^^^^^^^^ help: remove this
     |
     = note: `-D clippy::redundant-clone` implied by `-D warnings`

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-20 00:52:03 +01:00
Yang Zhong
5c4e1726f8 ci: test the vhost-user-blk readonly function
This patch is to check if block device is readonly
when backend set readonly=true.

The lsblk command can show the RO value in the guest.

Signed-off-by: Yang Zhong <yang.zhong@intel.com>
2019-12-18 09:45:11 +01:00
Rob Bradford
91549ddd71 tests: Add integration test for CPU unplug
Enhance the CPU hotplug test to also unplug the CPUs.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-18 08:23:53 +00:00
Sebastien Boeuf
43d2e09e1f ci: Add unit tests to compare CLI and OpenAPI
The goal here is to ensure that CLI and OpenAPI both behave as closely
as possible, and also that they behave as expected.

Leveraging the reorganization of the code, we can now compare two
VmConfig structures generated from one CLI entry on one side, and from
an OpenAPI entry (JSON payload) on the other side.

Fixes #535

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Sebastien Boeuf
43bd0e53c4 main: Move VmParams creation into a dedicated function
This brings more modularity to the code, which will be helpful when we
will later test the CLI and OpenAPI generate the same VmConfig output.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Sebastien Boeuf
17a167dbb6 main: Move default values preparation into a dedicated function
This brings more modularity to the code, which will be helpful when we
will later test the CLI and OpenAPI generate the same VmConfig output.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Sebastien Boeuf
9c3a7ddcc9 main: Move clap::App creation into a dedicated function
This brings more modularity to the code, which will be helpful when we
will later test the CLI and OpenAPI generate the same VmConfig output.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Rob Bradford
23150f8647 tests: Throttle tests based on disk space
On our CI the /tmp filesystem is mounted as tmpfs and this is the
location where the test disk images are located. When the CI worker
nodes have less memory and fewer CPUs the tmpfs fills up as the tests
run in parallel.

Introduce a mechanism to reduce the parallelism of the tests based on
starvation of the tmpfs disk availability.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-13 16:42:59 +01:00
Sebastien Boeuf
f7c215d92d cli: Fix default CPU argument
By default, and in order to avoid falling into the legacy CLI usage, the
CPU argument should at least include "boot=" to define the number of
CPUs.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
66e00ce710 ci: Extend VFIO integration test
In order to validate that multiple devices can be passed through and
they are still fully functional, this patch extends the existing VFIO
test to pass a second virtio-net device, and verifies that both
interfaces are functional by ssh'ing into each network interface.

Fixes #503

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-06 12:53:09 +01:00
Rob Bradford
fcf92d86b5 tests: Add rebooting to the CPU hotplug test
Check that the added vCPUs are still there after a reboot.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-05 16:39:19 +00:00
Rob Bradford
1722708612 vmm: Switch to storing VmConfig inside an Arc<Mutex<>>
This permits the runtime reconfiguration of the VM.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-05 16:39:19 +00:00
Rob Bradford
e1ff142392 tests: Remove MSI only test from test_serial_off
Now we have a GED device we are not MSI only when the serial port is
turned off.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-02 13:49:04 +00:00
Rob Bradford
e0830640b7 tests: Add integration test for hotplugging vCPUs
Resize the VM to increase the number of vCPUs.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-02 13:49:04 +00:00
Rob Bradford
ea19bb026f tests: Add a test to check that the boot vs max cpus work
The easiest way to detect if the kernel is willing to accept hotplug
vCPUs is to check the dmesg output.

Switch the test to bionic as the Clear Cloud image lacks "dmesg."

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-02 13:49:04 +00:00
Rob Bradford
4bc8635c59 tests: Use new "--cpus" syntax for integration tests
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-02 13:49:04 +00:00
Rob Bradford
82bc07cce4 vmm: Add boot and max vCPU handling to command line parser
Also retain support (with a warning for the old behaviour.)

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-02 13:49:04 +00:00
Sebastien Boeuf
f1c7f0c0b8 ci: Add integration test for vhost_user_fs daemon
In order to validate the new virtio-fs daemon written in Rust is
behaving correctly, a new integration test has been added. Important to
note that for now, only a test with cache=none and dax=off can be added
since the daemon does not support shared memory region yet.

The long term goal being to replace virtiofsd with vhost_user_daemon
once it will reach parity regarding the supported features.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-11-22 22:17:47 +01:00
Rob Bradford
ac118c9924 ci: Parse the smaps file with Rust
Instead of using bash and awk, using Rust allows us to retrieve
information about a VM process with the right permissions as we are not
forced to spawn a new child process.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-11-22 15:28:10 +00:00
Sebastien Boeuf
bdb7bcdbe3 ci: Add integration test for mergeable memory
The test validates that when the mergeable option is enabled, the
resulting PSS for two instances of cloud-hypervisor is lower than two
instances not using the mergeable flag.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-11-22 15:28:10 +00:00
Sebastien Boeuf
0f9afc3017 vmm: Add mergeable=on|off option to --pmem flag
In order to let the user indicate if the persistent memory pages should
be marked as mergeable or not, a new option is being introduced.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-11-22 15:28:10 +00:00
Sebastien Boeuf
880f62bab8 vmm: Add mergeable=on|off option to --memory flag
In order to let the user indicate if the guest RAM pages should be
marked as mergeable or not, a new option is being introduced.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-11-22 15:28:10 +00:00
Jose Carlos Venegas Munoz
1d852e9ce5 vmm: Provide vmm version to start_vmm_thread
When vmm.ping give a response, we expect get the version from
the VMM not the vmm create

Signed-off-by: Jose Carlos Venegas Munoz <jose.carlos.venegas.munoz@intel.com>
2019-11-21 15:04:11 -08:00
Jose Carlos Venegas Munoz
a518651402 http: api: implement vmm.ping
vmm.ping will help to check if http API server is up and
running.

This also removes the vmm.info endpoint.

Signed-off-by: Jose Carlos Venegas Munoz <jose.carlos.venegas.munoz@intel.com>
2019-11-21 15:04:11 -08:00
Sergio Lopez
c3eaa41b77 ci: use the new vhost-user-blk backend for integration tests
Use the new vhost-user-blk backend for the integration tests,
eliminating the need for building vubd using the implementation in
QEMU.

Signed-off-by: Sergio Lopez <slp@redhat.com>
2019-11-07 10:36:30 +00:00
Rob Bradford
ce386ba4c6 tests: Use release build for integration tests
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-10-31 10:07:37 -07:00
Sebastien Boeuf
296f2e1182 ci: Add integration test for PCI BAR reprogramming
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-29 16:48:02 +01:00
Sebastien Boeuf
05c7130f06 ci: Update ClearLinux image
A new ClearLinux image has been uploaded to the Azure storage account.
It is based off of the ClearLinux cloudguest image 31310 version, with
two extra bundles added to it.

First bundle is sysadmin-basic to include utility like netcat, and the
second bundle is iperf, adding the iperf binary to the image.

The image is 2G in size.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-18 16:49:46 +01:00
Jose Carlos Venegas Munoz
78e2f7a99a api: http: handle cpu according to openapi
openapi definition defines an object for cpus not an integer

Signed-off-by: Jose Carlos Venegas Munoz <jose.carlos.venegas.munoz@intel.com>
2019-10-17 07:39:56 +02:00
Sebastien Boeuf
63c30a6e79 vmm: Build and set the list of external mappings for VFIO
When VFIO devices are created and if the device is attached to the
virtual IOMMU, the ExternalDmaMapping trait implementation is created
and associated with the device. The idea is to build a hash map of
device IDs with their associated trait implementation.

This hash map is provided to the virtual IOMMU device so that it knows
how to properly trigger external mappings associated with VFIO devices.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-16 07:27:06 +02:00
Sebastien Boeuf
5fc3f37c9b vmm: Add iommu=on|off option for --device
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a VFIO device should be attached to the virtual
IOMMU or not. That's why we introduce an extra option "iommu" with the
value "on" or "off". By default, the device is not attached, which means
"iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-16 07:27:06 +02:00
Samuel Ortiz
af41d6fc88 main: Add VM pause/resume test
We pause a VM from the API, then SSH'ing into it should fail.
After resuming, SSH'ing should work again.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-10 17:13:44 -07:00
Sebastien Boeuf
80c3fd922a ci: Allow enough time for L2 VM to boot
Because the L2 VM running in the VFIO integration test is actually
running as L3 (since the CI runs in a VM), it can take quite some
time for this VM to boot.

The way to solve this issue is to extend the sleep time before to try
communicating with the L2 VM, but also to speed up the boot time by
using virtio-console instead of serial. We suspect the use of serial,
implying PIO VM exits for each character on the serial port is quite
expensive compared to the paravirtualized console.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-11 01:40:11 +02:00
Sebastien Boeuf
37a7000fdd ci: Make sure VFIO test don't conflict with Azure private IP
Azure virtual machines can have private IPs in the 172.16.x.x range,
causing some issues with the VFIO test. By using 172.17.x.x for this
test, we avoid IP conflicts.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-10 11:29:17 -07:00
Sebastien Boeuf
6e9e24ec0f ci: Extend virtio-iommu integration test
Now that our custom kernel includes all the patches for the full support
of virtio-iommu, we can go one step further by attaching the virtio-net
device to the virtual IOMMU and use it to SSH some commands validating
both disks and the network card are isolated into their own IOMMU group.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-10 16:07:50 +02:00
Sebastien Boeuf
1fc8ee945a ci: Remove QEMU dependency for nested VFIO test
Now that cloud-hypervisor can expose a virtual IOMMU to its guest VM,
the integration test validating the VFIO support with virtio-net can be
updated to use cloud-hypervisor exclusively.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-10 16:07:50 +02:00
Sebastien Boeuf
46848fdc43 ci: Add integration test for virtio-iommu
Simply test the guest can find the PCI device corresponding to the
virtio-iommu device.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
278ab05cbc vmm: Add iommu=on|off option for --vsock
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-vsock device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
32d07e40cc vmm: Add iommu=on|off option for --console
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-console device should be attached to
this virtual IOMMU or not. That's why we introduce an extra option
"iommu" with the value "on" or "off". By default, the device is not
attached, which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
63869bde75 vmm: Add iommu=on|off option for --pmem
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-pmem device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
fb4769388b vmm: Add iommu=on|off option for --rng
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-rng device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
20c4ed829a vmm: Add iommu=on|off option for --net
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-net device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
4b8d7e718d vmm: Add iommu=on|off option for --disk
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-blk device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

One side effect of this new option is that we had to introduce a new
option for the disk path, simply called "path=".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Samuel Ortiz
8dbb16df4d main: Add a simple HTTP API integration test
For now we test that we can create and boot a guest from the HTTP API.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
46cde1a38e vmm: Rename the VM start and stop operations to boot and shutdown
To match the OpenAPI description. And also to map the real life
terminology.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
ce0b475ef7 vmm: Move the VM creation and startup helpers to the api module
They're API wrappers, not VMM ones.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
f674019ea1 vmm: {De}serialize VmConfig
We use the serde crate to serialize and deserialize the VmVConfig
structure. This structure will be passed from the HTTP API caller as a
JSON payload and we need to deserialize it into a VmConfig.

For a convenient use of the HTTP API, we also provide Default traits
implementations for some of the VmConfig fields (vCPUs, memory, etc...).

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
aa31748781 vmm: Start the HTTP server thread
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
b14fd37db9 vmm: Make --kernel optional
The kernel path was the only mandatory command line option.
With the addition of the --api-socket option, we can run without a
kernel path and get it later through the API.

Since we can end up with VM configurations that are no longer valid by
default, we need to provide a validation check for it. For now, if the
kernel path is not defined, the VM configuration is invalid.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
f27aa21e3f main: Add API socket option
The API server will unconditionally run through a UNIX domain socket
which default path is /run/user/<uid>/cloud-hypervisor.<pid>.

The --api-socket command line option allows to override that default
value with some custom socket path.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Samuel Ortiz
fe5561df50 main: Group cli options logically
With the API server socket option, we will be able to support a model
where the user can start cloud-hypervisor with no options or an
alternative API server socket path. In this case, we don't want to try
to start a new guest VM, and for that we need to know if the user has
set any VM configuration at all. Grouping all VM configuration specific
options together is one way to be able to know about it.

If the user has not set any VM configuration, we only start the API
server. If it has set anything, we will verify that the overall
configuration is valid and will implicitly convert that configuration
into a request to the API server.

Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
2019-10-04 09:36:33 +02:00
Rob Bradford
df3e5c874f tests: Add support for integration testing Ubuntu "eoan"
Refactor the Ubuntu testing infrastructure to support testing different
versions.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-10-02 13:59:48 +01:00