To avoid race issues where the api-socket may not be created by the
time a cloud-hypervisor caller is ready to look for it, enable the
caller to pass the api-socket fd directly.
Avoid breaking current callers by allowing the --api-socket path to be
passed as it is now in addition to through the path argument.
Signed-off-by: William Douglas <william.r.douglas@gmail.com>
This allows the return of errors which will be printed using the
existing code and removes panic()s
Fixes: #2342
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This allows the return of errors which will be printed using the
existing code and removes panic()s
Fixes: #2342
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
warning: name `StartVMMThread` contains a capitalized acronym
--> src/main.rs:50:5
|
50 | StartVMMThread(#[source] vmm::Error),
| ^^^^^^^^^^^^^^ help: consider making the acronym lowercase, except the initial letter: `StartVmmThread`
|
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#upper_case_acronyms
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
warning: name `InvalidCPUCount` contains a capitalized acronym
--> src/bin/ch-remote.rs:24:5
|
24 | InvalidCPUCount(std::num::ParseIntError),
| ^^^^^^^^^^^^^^^ help: consider making the acronym lowercase, except the initial letter: `InvalidCpuCount`
|
= note: `#[warn(clippy::upper_case_acronyms)]` on by default
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#upper_case_acronyms
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Remove the startup message containing incomplete VM configuration
details. It's a bit unusual for a tool such as Cloud Hypervisor to print
those kind of details which are a direct representation of the command
line.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Only if we have a valid API server path then create the API server. For
now this has no functional change there is a default API server path in
the clap handling but rather prepares to do so optionally.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Replace "--monitor-fd" with "--event-monitor" which can either take
"fd=<int>" or "path=<path>" which can point to e.g. a named pipe and
allow more flexibility.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add the ability for cloud-hypervisor to create, manage and monitor a
pty for serial and/or console I/O from a user. The reasoning for
having cloud-hypervisor create the ptys is so that clients, libvirt
for example, could exit and later re-open the pty without causing I/O
issues. If the clients were responsible for creating the pty, when
they exit the main pty fd would close and cause cloud-hypervisor to
get I/O errors on writes.
Ideally the main and subordinate pty fds would be kept in the main
vmm's Vm structure. However, because the device manager owns parsing
the configuration for the serial and console devices, the information
is instead stored in new fields under the DeviceManager structure
directly.
From there hooking up the main fd is intended to look as close to
handling stdin and stdout on the tty as possible (there is some future
work ahead for perhaps moving support for the pty into the
vmm_sys_utils crate).
The main fd is used for reading user input and writing to output of
the Vm device. The subordinate fd is used to setup raw mode and it is
kept open in order to avoid I/O errors when clients open and close the
pty device.
The ability to handle multiple inputs as part of this change is
intentional. The current code allows serial and console ptys to be
created and both be used as input. There was an implementation gap
though with the queue_input_bytes needing to be modified so the pty
handlers for serial and console could access the methods on the serial
and console structures directly. Without this change only a single
input source could be processed as the console would switch based on
its input type (this is still valid for tty and isn't otherwise
modified).
Signed-off-by: William Douglas <william.r.douglas@gmail.com>
This allows the user to use an alternative huge page size otherwise the
default size will be used.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
If we receive SIGSYS and identify it as a seccomp violation then give
friendly instructions on how to debug further. We are unable to decode
the siginfo_t struct ourselves due to https://github.com/rust-lang/libc/issues/716Fixes: #2139
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Use a Result<> type with an error to simplify the code in start_vmm().
This will also make it easier to add cleanup funtionality.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Split out the HTTP request handling code from ch-remote into a new
crate which can be used in other places where talking to the API server
by HTTP is necessary.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Use the trait for Read/Write rather than specifying the concrete type.
This allows for the functionality to be used for different socket types.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The standalone `--balloon` parameter being fully functional at this
point, we can get rid of the balloon options from the --memory
parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Now that we have a new dedicated way of asking for a balloon through the
CLI and the REST API, we can move all the balloon code to the device
manager. This allows us to simplify the memory manager, which is already
quite complex.
It also simplifies the behavior of the balloon resizing command. Instead
of providing the expected size for the RAM, which is complex when memory
zones are involved, it now expects the balloon size. This is a much more
straightforward behavior as it really resizes the balloon to the desired
size. Additionally to the simplication, the benefit of this approach is
that it does not need to be tied to the memory manager at all.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This introduces a new way of defining the virtio-balloon device. Instead
of going through the --memory parameter, the idea is to consider balloon
as a standalone virtio device.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The watchdog device is created through the "--watchdog" parameter. At
most a single watchdog can be created per VM.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
In order to let the user choose maximum address space size, this patch
introduces a new option `max_phys_bits` to the `--cpus` parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This is a new clippy check introduced in 1.47 which requires the use of
the matches!() macro for simple match blocks that return a boolean.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The ::new() does very little beyond trying to open the /dev/kvm device
so provide a hint to the user about what has gone wrong.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add the new option 'hotplugged_size' to both --memory-zone and --memory
parameters so that we can let the user specify a certain amount of
memory being plugged at boot.
This is also part of making sure we can store the virtio-mem size over a
reboot of the VM.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Implement a new VM action called 'resize-zone' allowing the user to
resize one specific memory zone at a time. This relies on all the
preliminary work from the previous commits to resize each virtio-mem
device independently from each others.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for resizing support of an individual memory zone,
this commit introduces a new option 'hotplug_size' to '--memory-zone'
parameter. This defines the amount of memory that can be added through
each specific memory zone.
Because memory zone resize is tied to virtio-mem, make sure the user
selects 'virtio-mem' hotplug method, otherwise return an error.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The way to describe guest NUMA nodes has been updated through previous
commits, letting the user describe the full NUMA topology through the
--numa parameter (or NumaConfig).
That's why we can remove the deprecated and unused 'guest_numa_node'
option.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for allowing memory zones to be removed, but also in
anticipation for refactoring NUMA parameter, we introduce a mandatory
'id' option to the --memory-zone parameter.
This forces the user to provide a unique identifier for each memory zone
so that we can refer to these.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Through this new parameter, we give users the opportunity to specify a
set of CPUs attached to a NUMA node that has been previously created
from the --memory-zone parameter.
This parameter will be extended in the future to describe the distance
between multiple nodes.
For instance, if a user wants to attach CPUs 0, 1, 2 and 6 to a NUMA
node, here are two different ways of doing so:
Either
./cloud-hypervisor ... --numa id=0,cpus=0-2:6
Or
./cloud-hypervisor ... --numa id=0,cpus=0:1:2:6
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
With the introduction of this new option, the user will be able to
describe if a particular memory zone should belong to a specific NUMA
node from a guest perspective.
For instance, using '--memory-zone size=1G,guest_numa_node=2' would let
the user describe that a memory zone of 1G in the guest should be
exposed as being associated with the NUMA node 2.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Since memory zones have been introduced, it is now possible for a user
to specify multiple backends for the guest RAM. By adding a new option
'host_numa_node' to the 'memory-zone' parameter, we allow the guest RAM
to be backed by memory that might come from a specific NUMA node on the
host.
The option expects a node identifier, specifying which NUMA node should
be used to allocate the memory associated with a specific memory zone.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The flag 'mergeable' should only apply to the entire guest RAM, which is
why it is removed from the MemoryZoneConfig as it is defined as a global
parameter at the MemoryConfig level.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
After the introduction of user defined memory zones, we can now remove
the deprecated 'file' option from --memory parameter. This makes this
parameter simpler, letting more advanced users define their own custom
memory zones through the dedicated parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Introducing a new CLI option --memory-zone letting the user specify
custom memory zones. When this option is present, the --memory size
must be explicitly set to 0.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>