Commit Graph

91 Commits

Author SHA1 Message Date
Damjan Georgievski
4db252b418 main, vmm: add --initramfs cli option
currently unused, the initramfs argument is added to the cli,
and stored in vmm::config:VmConfig as an Option(InitramfsConfig(PathBuf))

Signed-off-by: Damjan Georgievski <gdamjan@gmail.com>
2020-03-26 11:59:03 +01:00
Rob Bradford
9df601a1df bin, vmm: Centralise the net syntax
This will allow the syntax to be reused with cloud-hypervsor binary and
ch-remote.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-25 17:58:06 +01:00
Hui Zhu
e6b934a56a vmm: Add support for virtio-mem
This commit adds new option hotplug_method to memory config.
It can set the hotplug method to "acpi" or "virtio-mem".

Signed-off-by: Hui Zhu <teawater@antfin.com>
2020-03-25 15:54:16 +01:00
Rob Bradford
a7296bbb52 bin, vmm: Centralise the pmem syntax
This will allow the syntax to be reused with cloud-hypervisor binary and
ch-remote.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-25 13:18:17 +01:00
Rob Bradford
66da29d8dd bin, vmm: Centralise the disk syntax
This will allow the syntax to be reused with cloud-hypervsor binary and
ch-remote.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-25 09:35:53 +00:00
Rob Bradford
f7197e8415 vmm: Add a "discard_writes=" to --pmem
This opens the backing file read-only, makes the pages in the mmap()
read-only and also makes the KVM mapping read-only. The file is also
mapped with MAP_PRIVATE to make the changes local to this process only.

This is functional alternative to having support for making a
virtio-pmem device readonly. Unfortunately there is no concept of
readonly virtio-pmem (or any type of NVDIMM/PMEM) in the Linux kernel so
to be able to have a block device that is appears readonly in the guest
requires significant specification and kernel changes.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-20 14:46:34 +01:00
Rob Bradford
477bc17f18 bin: Share VFIO device syntax between cloud-hypervisor and ch-remote
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-18 23:38:55 +00:00
Rob Bradford
4579afa091 vmm: For --disk error if socket and path is specified
This is an error as the path should be specfied by the unmanaged
backend.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-13 11:41:52 +00:00
Rob Bradford
7e599b4450 vmm: Make disk path optional
When using "--disk" with a vhost socket and not using self spawning then
it is not necessary or helpful to specify the path.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-03-13 11:41:52 +00:00
Sebastien Boeuf
9023444ad3 vmm: Add id field to --device through CLI
Add the ability to specify the "id" associated with a device, by adding
an extra option to the parameter --device.

This new option is not mandatory, and by default, the VMM will take care
of finding a unique identifier.

If the identifier provided by the user through this new option is not
unique, an error will be thrown and the VM won't be started.

Fixes #881

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-03-11 13:10:57 +00:00
Sebastien Boeuf
81173bf4ab vmm: Add id field to DeviceConfig structure
Add a new field to the DeviceConfig, allowing the VMM to allocate a name
to the VFIO devices.

By identifying a VFIO device with a unique name, we can make sure a user
can properly unplug it at any time.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-03-10 17:05:06 +00:00
Rob Bradford
bba5ef3a59 vmm: Remove deprecated CPU syntax
Remove the old way of specifying the number of vCPUs to use.

Fixes: #678

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-24 07:26:31 +01:00
Rob Bradford
374ac77c63 main, vmm: Remove deprecated --vhost-user-net
This has been superseded by using --net with vhost_user=true and
socket=<socket>

Fixes: #678

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-24 07:26:31 +01:00
Rob Bradford
ffd816ebfa main, vmm: Remove deprecated --vhost-user-blk
This has been superseded by using --disk with vhost_user=true and
socket=<socket>

Fixes: #678

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-24 07:26:31 +01:00
Sergio Lopez
d2f1749edb vmm: config: Add poll_queue property to DiskConfig
Recently, vhost_user_block gained the ability of actively polling the
queue, a feature that can be disabled with the poll_queue property.

This change adds this property to DiskConfig, so it can be used
through the "disk" argument.

For the moment, it can only be used when vhost_user=true, but this
will change once virtio-block gets the poll_queue feature too.

Fixes: #787

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-02-20 18:06:54 +01:00
Rob Bradford
1f6cbad01a vmm: Add support for spawning vhost-user-block backend
If no socket is supplied when enabling "vhost_user=true" on "--disk"
follow the "exe" path in the /proc entry for this process and launch the
network backend (via the vmm_path field.)

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-18 08:43:47 +00:00
Rob Bradford
bc75c1b4e1 vmm: Add support for spawning vhost-user-net backend
If no socket is supplied when enabling "vhost_user=true" on "--net"
follow the "exe" path in the /proc entry for this process and launch the
network backend (via the vmm_path field.)

Currently this only supports creating a new tap interface as the network
backend also only supports that.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-02-14 17:32:49 +00:00
Rob Bradford
75e6762897 vmm: Give deprecation warning for "--vhost-user-blk" syntax
This will be removed in a future release.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-29 08:06:37 +00:00
Rob Bradford
969b5ee4e8 vmm: config: Add warning about specifying "wce" without "vhost-user"
Currently configuring WCE is only supported when using vhost-user.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-29 08:06:37 +00:00
Rob Bradford
aeeae661fc vmm: Support vhost-user-block via "--disks"
Add a socket and vhost_user parameter to this option so that the same
configuration option can be used for both virtio-block and
vhost-user-block.  For now it is necessary to specify both vhost_user
and socket parameters as auto activation is not yet implemented. The wce
parameter for supporting "Write Cache Enabling" is also added to the
disk configuration.

The original command line parameter is still supported for now and will
be removed in a future release.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-29 08:06:37 +00:00
Rob Bradford
2c6f528c23 vmm: Give deprecation warning for "--vhost-user-net" syntax
This will be removed in a future release.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-28 12:39:26 +00:00
Rob Bradford
a831aa214c vmm: Support vhost-user-net via "--net"
Add a socket and vhost_user parameter to this option so that the same
configuration option can be used for both virtio-net and vhost-user-net.
For now it is necessary to specify both vhost_user and socket parameters
as auto activation is not yet implemented. The original command line
parameter is still supported for now.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-28 12:39:26 +00:00
Sebastien Boeuf
08e47ebd4b vmm: Add num_queues and queue_size parameters to virtio-blk
The number of queues and the size of each queue were not configurable.
In anticipation for adding multiqueue support, this commit introduces
some new parameters to let the user decide about the number of queues
and the queue size.

Note that the default values for each of these parameters are identical
to the default values used for vhost-user-blk, that is 1 for the number
of queues and 128 for the queue size.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-28 09:26:53 +01:00
Sebastien Boeuf
06396593c9 net_util: Fix map_err losing the inner error
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2020-01-24 12:42:09 +01:00
Sergio Lopez
925c862f98 vmm: device_manager: Add 'direct' support for virtio-blk
vhost_user_blk already has it, so it's only fair to give it to
virtio-blk too. Extend DiskConfig with a 'direct' property, honor
it while opening the file backing the disk image, and pass it to
vm_virtio::RawFile.

Fixes #631

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-01-21 13:39:45 +00:00
Sergio Lopez
fb79e75afc vmm: device_manager: Add read-only support for virtio-blk
vhost_user_blk already has it, so it's only fair to give it to
virtio-blk too. Extend DiskConfig with a 'readonly' properly, and pass
it to vm_virtio::Block.

Signed-off-by: Sergio Lopez <slp@redhat.com>
2020-01-21 13:39:45 +00:00
Cathy Zhang
404316eea1 vmm: Add multiple queue option and update config for virtio-net device
Add num_queues and queue_size for virtio-net device to make them configurable,
while add the associated options in command line.

Update cloud-hypervisor.yaml with the new options for NetConfig.

Signed-off-by: Cathy Zhang <cathy.zhang@intel.com>
2020-01-17 12:06:19 +01:00
Rob Bradford
f5137e84bb vmm, main: Add optional "hotplug_size" to --mem
This specifies how much address space should be reserved for hotplugging
of RAM. This space is reserved by adding move the start of the device
area by the desired amount.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2020-01-15 20:21:22 +01:00
Sebastien Boeuf
d1390906c8 vmm: config: Derive Debug and PartialEq for configuration structures
In anticipation for the writing of unit tests comparing two VmConfig
structures, this commit derives the PartialEq trait for VmConfig and
all embedded structures.

This patch also derives the Debug trait for the same set of structures
so that we can print them to facilitate debugging.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Sebastien Boeuf
93f5f6ed45 vmm: config: Provide a default empty command line through OpenAPI
The OpenAPI should not have to provide a command line since the CLI
considers the command line as an empty string if nothing is provided.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Sebastien Boeuf
43bd0e53c4 main: Move VmParams creation into a dedicated function
This brings more modularity to the code, which will be helpful when we
will later test the CLI and OpenAPI generate the same VmConfig output.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-16 16:48:59 +01:00
Sebastien Boeuf
64c5e3d8cb vmm: api: Adjust FsConfig for OpenAPI
The FsConfig structure has been recently adjusted so that the default
value matches between OpenAPI and CLI. Unfortunately, with the current
description, there is no way from the OpenAPI to describe a cache_size
value "None", so that DAX does not get enabled. Usually, using a Rust
"Option" works because the default value is None. But in this case, the
default value is Some(8G), which means we cannot describe a None.

This commit tackles the problem, introducing an explicit parameter
"dax", and leaving "cache_size" as a simple u64 integer.

This way, the default value is dax=true and cache_size=8G, but it lets
the opportunity to disable DAX entirely with dax=false, which will
simply ignore the cache_size value.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
4bfd51cc42 vmm: api: Match VhostUserBlkConfig defaults between CLI and HTTP API
In order to let the CLI and the HTTP API behave the same regarding the
VhostUserBlkConfig structure, this patch defines some default values
for num_queues, queue_size and wce.

num_queues is 1, queue_size is 128 and wce is true.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
1c2587f8cb vmm: api: Match VhostUserNetConfig defaults between CLI and HTTP API
In order to let the CLI and the HTTP API behave the same regarding the
VhostUserNetConfig structure, this patch defines some default values
for num_queues, queue_size and mac.

num_queues is 2 since that's a pair of TX/RX queues, queue_size is 256
and mac is a randomly generated value.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
5e0bbf9c3b vmm: Don't factorize vhost-user configurations
We want to set different default configurations for vhost-user-net and
vhost-user-blk, which is the reason why the common part corresponding to
the number of queues and the queue size cannot be embedded.

This prepares for the following commit, matching API and CLI behaviors.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
793327cff8 vmm: api: Make ConsoleConfig default match between CLI and HTTP API
A simple patch making sure the field "file" is provisioned with the same
default value through CLI and OpenAPI.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
cc08c44cb9 vmm: api: Make MemoryConfig default match between CLI and HTTP API
Just making sure we have a serde default for the field "file" since it
is not a required field in the OpenAPI definition.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-11 15:50:24 +00:00
Sebastien Boeuf
ee528ae808 vmm: api: Make FsConfig defaults match between CLI and HTTP API
In order to let the CLI and the HTTP API behave the same regarding the
FsConfig structure, this patch defines some default values for
num_queues, queue_size and the cache_size.

num_queues is set to 1, queue_size is set to 1024, and cache_size is set
to Some(8G) which means that DAX is enabled by default with a shared
region of 8GiB.

Fixes #508

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-09 23:42:23 -08:00
Sebastien Boeuf
befd342da4 vmm: api: Make NetConfig defaults match between CLI and HTTP API
In order to let the CLI and the HTTP API behave the same regarding the
NetConfig structure, this patch defines some default values for tap, ip,
mask, mac and iommu.

tap is None, ip is 192.168.249.1, mask is 255.255.255.0, mac is a
randomly generated value, and iommu is false.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-09 23:19:24 -08:00
Sebastien Boeuf
aa94e9b8f3 Revert "vmm: api: Modify FsConfig to be OpenAPI friendly"
This reverts commit defc5dcd9c.
2019-12-06 18:08:10 +00:00
Sebastien Boeuf
defc5dcd9c vmm: api: Modify FsConfig to be OpenAPI friendly
When consumer of the HTTP API try to interact with cloud-hypervisor,
they have to provide the equivalent of the config structure related to
each component they need. Problem is, the Rust enum type "Option" cannot
be obtained from the OpenAPI YAML definition.

This patch intends to fix this inconsistency between what is possible
through the CLI and what's possible through the HTTP API by using simple
types bool and int64 instead of Option<u64>.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-12-06 06:38:48 -08:00
Rob Bradford
82bc07cce4 vmm: Add boot and max vCPU handling to command line parser
Also retain support (with a warning for the old behaviour.)

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-12-02 13:49:04 +00:00
Sebastien Boeuf
0f9afc3017 vmm: Add mergeable=on|off option to --pmem flag
In order to let the user indicate if the persistent memory pages should
be marked as mergeable or not, a new option is being introduced.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-11-22 15:28:10 +00:00
Sebastien Boeuf
880f62bab8 vmm: Add mergeable=on|off option to --memory flag
In order to let the user indicate if the guest RAM pages should be
marked as mergeable or not, a new option is being introduced.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-11-22 15:28:10 +00:00
Rob Bradford
3c715daa9d vmm: Fix rustfmt failure by removing extra ";"
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2019-11-08 20:43:52 +00:00
Jose Carlos Venegas Munoz
78e2f7a99a api: http: handle cpu according to openapi
openapi definition defines an object for cpus not an integer

Signed-off-by: Jose Carlos Venegas Munoz <jose.carlos.venegas.munoz@intel.com>
2019-10-17 07:39:56 +02:00
Sebastien Boeuf
5fc3f37c9b vmm: Add iommu=on|off option for --device
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a VFIO device should be attached to the virtual
IOMMU or not. That's why we introduce an extra option "iommu" with the
value "on" or "off". By default, the device is not attached, which means
"iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-16 07:27:06 +02:00
Sebastien Boeuf
278ab05cbc vmm: Add iommu=on|off option for --vsock
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-vsock device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
32d07e40cc vmm: Add iommu=on|off option for --console
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-console device should be attached to
this virtual IOMMU or not. That's why we introduce an extra option
"iommu" with the value "on" or "off". By default, the device is not
attached, which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00
Sebastien Boeuf
63869bde75 vmm: Add iommu=on|off option for --pmem
Having the virtual IOMMU created with --iommu is one thing, but we also
need a way to decide if a virtio-pmem device should be attached to this
virtual IOMMU or not. That's why we introduce an extra option "iommu"
with the value "on" or "off". By default, the device is not attached,
which means "iommu=off".

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2019-10-07 10:12:07 +02:00