In order to let the user choose maximum address space size, this patch
introduces a new option `max_phys_bits` to the `--cpus` parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The ::new() does very little beyond trying to open the /dev/kvm device
so provide a hint to the user about what has gone wrong.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add the new option 'hotplugged_size' to both --memory-zone and --memory
parameters so that we can let the user specify a certain amount of
memory being plugged at boot.
This is also part of making sure we can store the virtio-mem size over a
reboot of the VM.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for resizing support of an individual memory zone,
this commit introduces a new option 'hotplug_size' to '--memory-zone'
parameter. This defines the amount of memory that can be added through
each specific memory zone.
Because memory zone resize is tied to virtio-mem, make sure the user
selects 'virtio-mem' hotplug method, otherwise return an error.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The way to describe guest NUMA nodes has been updated through previous
commits, letting the user describe the full NUMA topology through the
--numa parameter (or NumaConfig).
That's why we can remove the deprecated and unused 'guest_numa_node'
option.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for allowing memory zones to be removed, but also in
anticipation for refactoring NUMA parameter, we introduce a mandatory
'id' option to the --memory-zone parameter.
This forces the user to provide a unique identifier for each memory zone
so that we can refer to these.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Through this new parameter, we give users the opportunity to specify a
set of CPUs attached to a NUMA node that has been previously created
from the --memory-zone parameter.
This parameter will be extended in the future to describe the distance
between multiple nodes.
For instance, if a user wants to attach CPUs 0, 1, 2 and 6 to a NUMA
node, here are two different ways of doing so:
Either
./cloud-hypervisor ... --numa id=0,cpus=0-2:6
Or
./cloud-hypervisor ... --numa id=0,cpus=0:1:2:6
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
With the introduction of this new option, the user will be able to
describe if a particular memory zone should belong to a specific NUMA
node from a guest perspective.
For instance, using '--memory-zone size=1G,guest_numa_node=2' would let
the user describe that a memory zone of 1G in the guest should be
exposed as being associated with the NUMA node 2.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Since memory zones have been introduced, it is now possible for a user
to specify multiple backends for the guest RAM. By adding a new option
'host_numa_node' to the 'memory-zone' parameter, we allow the guest RAM
to be backed by memory that might come from a specific NUMA node on the
host.
The option expects a node identifier, specifying which NUMA node should
be used to allocate the memory associated with a specific memory zone.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The flag 'mergeable' should only apply to the entire guest RAM, which is
why it is removed from the MemoryZoneConfig as it is defined as a global
parameter at the MemoryConfig level.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
After the introduction of user defined memory zones, we can now remove
the deprecated 'file' option from --memory parameter. This makes this
parameter simpler, letting more advanced users define their own custom
memory zones through the dedicated parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Introducing a new CLI option --memory-zone letting the user specify
custom memory zones. When this option is present, the --memory size
must be explicitly set to 0.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This patch extends the CLI option '--seccomp' to accept the 'log'
parameter in addition 'true/false'. It also refactors the
vmm::seccomp_filters module to support both "SeccompAction::Trap" and
"SeccompAction::Log".
Fixes: #1180
Signed-off-by: Bo Chen <chen.bo@intel.com>
This patch replaces the usage of 'SeccompLevel' with 'SeccompAction',
which is the first step to support the 'log' action over system
calls that are not on the allowed list of seccomp filters.
Signed-off-by: Bo Chen <chen.bo@intel.com>
Introducing the new CLI option --sgx-epc along with the OpenAPI
structure SgxEpcConfig, so that a user can now enable one or multiple
SGX Enclave Page Cache sections within a contiguous region from the
guest address space.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This commit store balloon size to MemoryConfig.
After reboot, virtio-balloon can use this size to inflate back to
the size before reboot.
Signed-off-by: Hui Zhu <teawater@antfin.com>
Start moving the vmm, arch and pci crates to being hypervisor agnostic
by using the hypervisor trait and abstractions. This is not a complete
switch and there are still some remaining KVM dependencies.
Signed-off-by: Muminul Islam <muislam@microsoft.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
This needed to be updated to include specifying the boot and maxmium
vCPUs as well as the newly added topology for those vCPUs.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This allows the user to optionally specify the desired CPU topology. All
parts of the topology must be specified and the product of all parts
must match the maximum vCPUs.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Currently, not every feature of the cloud-hypervisor is enabled
on AArch64, which means that on AArch64 machines, the
`run_unit_tests.sh` needs to be tailored and some unit test cases
should be run on x86_64 only.
Also this commit fixes the typo and unifies `Arm64` and `AArch64`
in the AArch64 document.
Signed-off-by: Henry Wang <Henry.Wang@arm.com>
This config option provided very little value and instead we now enable
this feature (which then lets the guest control the cache mode)
unconditionally.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add a new "host_mac" parameter to "--net" and "--net-backend" and use
this to set the MAC address on the tap interface. If no address is given
one is randomly assigned and is stored in the config.
Support for vhost-user-net self spawning was also included.
Fixes: #1177
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Rather than repeat syntax for the vhost-user-block backend in multiple
places store it in one place and reference it from the required places.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Rather than repeat syntax for the vhost-user-net backend in multiple
places store it in one place and reference it from the required places.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
It's possible to have multiple vsock devices so in preparation for
hotplug/unplug it is important to be able to have a unique identifier
for each device.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Check that if any device using vhost-user (net & disk with
vhost_user=true) or virtio-fs is enabled then check shared memory is
also enabled.
Fixes: #848
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The new 'shared' and 'hugepages' controls aim to replace the 'file'
option in MemoryConfig. This patch also updated all related integration
tests to use the new controls (instead of providing explicit paths to
"/dev/shm" or "/dev/hugepages").
Fixes: #1011
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Signed-off-by: Bo Chen <chen.bo@intel.com>
Currently unimplemented. Once implemented, this API will allow for
creating virtio-fs devices in the VM after it has booted.
Signed-off-by: Dean Sheather <dean@coder.com>
As the VmConfig::Parse() also does validation work it only make sense to
parse the VM options on the VM boot path only.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Replace the existing VmConfig::valid() check with a call into
.validate() as part of earlier config setup or boot API checks.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The goal here is to move the restore parameters into a dedicated
structure that can be reused from the entire codebase, making the
addition or removal of a parameter easier.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
currently unused, the initramfs argument is added to the cli,
and stored in vmm::config:VmConfig as an Option(InitramfsConfig(PathBuf))
Signed-off-by: Damjan Georgievski <gdamjan@gmail.com>