With the introduction of a new option `affinity` to the `cpus`
parameter, Cloud Hypervisor can now let the user choose the set
of host CPUs where to run each vCPU.
This is useful when trying to achieve CPU pinning, as well as making
sure the VM runs on a specific NUMA node.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Give the option parser the ability to handle tuples with inner brackets
containing list of integers. The following example can now be handled
correctly "option=[key@[v1-v2,v3,v4]]" which means the option is
assigned a tuple with a key associated with a list of integers between
the range v1 - v2, as well as v3 and v4.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Creates a new generic type Tuple so that the same implementation of
FromStr trait can be reused for both parsing a list of two integers and
parsing a list of one integer associated with a list of integers.
This anticipates the need for retrieving sublists, which will be needed
when trying to describe the host CPU affinity for every vCPU.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The elements of a list should be using commas as the correct delimiter
now that it is supported. Deprecate use of colons as delimiter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
For all the devices that support being hotplugged (disk, net, pmem, fs
and vsock) add "pci_segment" option and propagate that through to the
addition onto the PCI busses.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This currently contains only the number over PCI segments to create.
This is limited to 16 at the moment which should allow 496 user specified
PCI devices.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
When using PVH for booting (which we use for all firmwares and direct
kernel boot) the Linux kernel does not configure LA57 correctly. As such
we need to limit the address space to the maximum 4-level paging address
space.
If the user knows that their guest image can take advantage of the
5-level addressing and they need it for their workload then they can
increase the physical address space appropriately.
This PR removes the TDX specific handling as the new address space limit
is below the one that that code specified.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The argument `prefault` is provided in MemoryManager, but it can
only be used by SGX and restore.
With prefault (MAP_POPULATE) been set, subsequent page faults will
decrease during running, although it will make boot slower.
This commit adds `prefault` in MemoryConfig and MemoryZoneConfig.
To resolve conflict between memory and restore, argument
`prefault` has been changed from `bool` to `Option<bool>`, when
its value is None, config from memory will be used, otherwise
argument in Option will be used.
Signed-off-by: Yu Li <liyu.yukiteru@bytedance.com>
This concept ends up being broken with multiple types on input connected
e.g. console on TTY and serial on PTY. Already the code for checking for
injecting into the serial device checks that the serial is configured.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
It is forbidden that the same memory zone belongs to more than one
NUMA node. This commit adds related validation to the `--numa`
parameter to prevent the user from specifying such configuration.
Signed-off-by: Henry Wang <Henry.Wang@arm.com>
Correct operation of user devices (vfio-user) requires shared memory so
flag this to prevent it from failing in strange ways.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This allows the user to specify devices that are running in a different
userspace process and communicated with vfio-user.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This new option allows the user to define a list of SGX EPC sections
attached to a specific NUMA node.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In order to uniquely identify each SGX EPC section, we introduce a
mandatory option `id` to the `--sgx-epc` parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Sometimes we need balloon deflate automatically to give memory
back to guest, especially for some low priority guest processes
under memory pressure. Enable deflate_on_oom to support this.
Usage: --balloon "size=0,deflate_on_oom=on" \
Signed-off-by: Fei Li <lifei.shirley@bytedance.com>
Adding the support for an OVS vhost-user backend to connect as the
vhost-user client. This means we introduce with this patch a new
option to our `--net` parameter. This option is called 'server' in order
to ask the VMM to run as the server for the vhost-user socket.
Fixes#1745
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
error: name `FinalizeTDX` contains a capitalized acronym
--> vmm/src/vm.rs:274:5
|
274 | FinalizeTDX(hypervisor::HypervisorVmError),
| ^^^^^^^^^^^ help: consider making the acronym lowercase, except the initial letter: `FinalizeTdx`
|
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#upper_case_acronyms
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
warning: name `LocalAPIC` contains a capitalized acronym
--> vmm/src/cpu.rs:197:8
|
197 | struct LocalAPIC {
| ^^^^^^^^^ help: consider making the acronym lowercase, except the initial letter: `LocalApic`
|
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#upper_case_acronyms
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The help information displayed for our `--disk` option is incorrect and
incomplete, e.g. missing the `direct` and `poll_queue` field.
Signed-off-by: Bo Chen <chen.bo@intel.com>
If the function can never return an error this is now a clippy failure:
error: this function's return value is unnecessarily wrapped by `Result`
--> virtio-devices/src/watchdog.rs:215:5
|
215 | / fn set_state(&mut self, state: &WatchdogState) -> io::Result<()> {
216 | | self.common.avail_features = state.avail_features;
217 | | self.common.acked_features = state.acked_features;
218 | | // When restoring enable the watchdog if it was previously enabled. We reset the timer
... |
223 | | Ok(())
224 | | }
| |_____^
|
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#unnecessary_wraps
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add the ability for cloud-hypervisor to create, manage and monitor a
pty for serial and/or console I/O from a user. The reasoning for
having cloud-hypervisor create the ptys is so that clients, libvirt
for example, could exit and later re-open the pty without causing I/O
issues. If the clients were responsible for creating the pty, when
they exit the main pty fd would close and cause cloud-hypervisor to
get I/O errors on writes.
Ideally the main and subordinate pty fds would be kept in the main
vmm's Vm structure. However, because the device manager owns parsing
the configuration for the serial and console devices, the information
is instead stored in new fields under the DeviceManager structure
directly.
From there hooking up the main fd is intended to look as close to
handling stdin and stdout on the tty as possible (there is some future
work ahead for perhaps moving support for the pty into the
vmm_sys_utils crate).
The main fd is used for reading user input and writing to output of
the Vm device. The subordinate fd is used to setup raw mode and it is
kept open in order to avoid I/O errors when clients open and close the
pty device.
The ability to handle multiple inputs as part of this change is
intentional. The current code allows serial and console ptys to be
created and both be used as input. There was an implementation gap
though with the queue_input_bytes needing to be modified so the pty
handlers for serial and console could access the methods on the serial
and console structures directly. Without this change only a single
input source could be processed as the console would switch based on
its input type (this is still valid for tty and isn't otherwise
modified).
Signed-off-by: William Douglas <william.r.douglas@gmail.com>
This allows the user to use an alternative huge page size otherwise the
default size will be used.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This patch enables multi-queue support for creating virtio-net devices by
accepting multiple TAP fds, e.g. '--net fds=3:7'.
Fixes: #2164
Signed-off-by: Bo Chen <chen.bo@intel.com>
Add an "fd=" parameter to allow specifying a TAP fd to use. Currently
only one fd for one queue pair is supported.
Fixes: #2052
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add config parameter to --disk called "_disable_io_uring" (the
underscore prefix indicating it is not for public consumpion.) Use this
option to disable io_uring if it would otherwise be used.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The standalone `--balloon` parameter being fully functional at this
point, we can get rid of the balloon options from the --memory
parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This introduces a new way of defining the virtio-balloon device. Instead
of going through the --memory parameter, the idea is to consider balloon
as a standalone virtio device.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The watchdog device is created through the "--watchdog" parameter. At
most a single watchdog can be created per VM.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
In order to let the user choose maximum address space size, this patch
introduces a new option `max_phys_bits` to the `--cpus` parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This is a new clippy check introduced in 1.47 which requires the use of
the matches!() macro for simple match blocks that return a boolean.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The virtio-balloon change the memory size is asynchronous.
VirtioBalloonConfig.actual of balloon device show current balloon size.
This commit add memory_actual_size to vm.info to show memory actual size.
Signed-off-by: Hui Zhu <teawater@antfin.com>
Misspellings were identified by https://github.com/marketplace/actions/check-spelling
* Initial corrections suggested by Google Sheets
* Additional corrections by Google Chrome auto-suggest
* Some manual corrections
Signed-off-by: Josh Soref <jsoref@users.noreply.github.com>
Add the new option 'hotplugged_size' to both --memory-zone and --memory
parameters so that we can let the user specify a certain amount of
memory being plugged at boot.
This is also part of making sure we can store the virtio-mem size over a
reboot of the VM.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for resizing support of an individual memory zone,
this commit introduces a new option 'hotplug_size' to '--memory-zone'
parameter. This defines the amount of memory that can be added through
each specific memory zone.
Because memory zone resize is tied to virtio-mem, make sure the user
selects 'virtio-mem' hotplug method, otherwise return an error.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The goal of this commit is to rename the existing NUMA option 'id' with
'guest_numa_id'. This is done without any modification to the way this
option behaves.
The reason for the rename is caused by the observation that all other
parameters with an option called 'id' expect a string to be provided.
Because in this particular case we expect a u32 representing a proximity
domain from the ACPI specification, it's better to name it with a more
explicit name.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The way to describe guest NUMA nodes has been updated through previous
commits, letting the user describe the full NUMA topology through the
--numa parameter (or NumaConfig).
That's why we can remove the deprecated and unused 'guest_numa_node'
option.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This new option provides a new way to describe the memory associated
with a NUMA node. This is the first step before we can remove the
'guest_numa_node' option from the --memory-zone parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In anticipation for allowing memory zones to be removed, but also in
anticipation for refactoring NUMA parameter, we introduce a mandatory
'id' option to the --memory-zone parameter.
This forces the user to provide a unique identifier for each memory zone
so that we can refer to these.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
By introducing 'distances' option, we let the user describe a list of
destination NUMA nodes with their associated distances compared to the
current node (defined through 'id').
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Through this new parameter, we give users the opportunity to specify a
set of CPUs attached to a NUMA node that has been previously created
from the --memory-zone parameter.
This parameter will be extended in the future to describe the distance
between multiple nodes.
For instance, if a user wants to attach CPUs 0, 1, 2 and 6 to a NUMA
node, here are two different ways of doing so:
Either
./cloud-hypervisor ... --numa id=0,cpus=0-2:6
Or
./cloud-hypervisor ... --numa id=0,cpus=0:1:2:6
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
With the introduction of this new option, the user will be able to
describe if a particular memory zone should belong to a specific NUMA
node from a guest perspective.
For instance, using '--memory-zone size=1G,guest_numa_node=2' would let
the user describe that a memory zone of 1G in the guest should be
exposed as being associated with the NUMA node 2.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Given that ACPI uses u32 as the type for the Proximity Domain, we can
use u32 instead of u64 as the type for 'host_numa_node' option.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Since memory zones have been introduced, it is now possible for a user
to specify multiple backends for the guest RAM. By adding a new option
'host_numa_node' to the 'memory-zone' parameter, we allow the guest RAM
to be backed by memory that might come from a specific NUMA node on the
host.
The option expects a node identifier, specifying which NUMA node should
be used to allocate the memory associated with a specific memory zone.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The flag 'mergeable' should only apply to the entire guest RAM, which is
why it is removed from the MemoryZoneConfig as it is defined as a global
parameter at the MemoryConfig level.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
After the introduction of user defined memory zones, we can now remove
the deprecated 'file' option from --memory parameter. This makes this
parameter simpler, letting more advanced users define their own custom
memory zones through the dedicated parameter.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Introducing a new CLI option --memory-zone letting the user specify
custom memory zones. When this option is present, the --memory size
must be explicitly set to 0.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Introducing the new CLI option --sgx-epc along with the OpenAPI
structure SgxEpcConfig, so that a user can now enable one or multiple
SGX Enclave Page Cache sections within a contiguous region from the
guest address space.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
This commit store balloon size to MemoryConfig.
After reboot, virtio-balloon can use this size to inflate back to
the size before reboot.
Signed-off-by: Hui Zhu <teawater@antfin.com>
Remove the vmm dependency from vhost_user_block and vhost_user_net where
it was existing to use config::OptionParser. By moving the OptionParser
to its own crate at the top-level we can remove the very heavy
dependency that these vhost-user backends had.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Split the generic virtio code (queues and device type) from the
VirtioDevice trait, transport and device implementations.
This also simplifies the feature handling in vhost_user_backend as the
vm-virtio crate is no longer has any features.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This allows the user to optionally specify the desired CPU topology. All
parts of the topology must be specified and the product of all parts
must match the maximum vCPUs.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This removes the need to use CAP_NET_ADMIN privileges and instead the
host MAC addres is either provided by the user or alternatively it is
retrieved from the kernel.
TEST=Run cloud-hypervisor without CAP_NET_ADMIN permission and a
preconfigured tap device:
sudo ip tuntap add name tap0 mode tap
sudo ifconfig tap0 192.168.249.1 netmask 255.255.255.0 up
cargo clean
cargo build
target/debug/cloud-hypervisor --serial tty --console off --kernel ~/src/rust-hypervisor-firmware/target/target/release/hypervisor-fw --disk path=~/workloads/clear-33190-kvm.img --net tap=tap0
VM was also rebooted to check that works correctly.
Fixes: #1274
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This config option provided very little value and instead we now enable
this feature (which then lets the guest control the cache mode)
unconditionally.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add a new "host_mac" parameter to "--net" and "--net-backend" and use
this to set the MAC address on the tap interface. If no address is given
one is randomly assigned and is stored in the config.
Support for vhost-user-net self spawning was also included.
Fixes: #1177
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Like the actions that don't take data such as "pause" or "resume" use a
common handler implementation to remove duplicated code for handling
simple endpoints like the hotplug ones.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Switch to using the recently added OptionParser in the code that parses
the block backend.
Fixes: #1092
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Generate an error during validation if an attempt it made to place a
device behind an IOMMU or using a VFIO device when not using PCI.
Fixes: #751
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
By giving the devices ids this effectively enables the removal of the
device.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
It's possible to have multiple vsock devices so in preparation for
hotplug/unplug it is important to be able to have a unique identifier
for each device.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
If a size is specified use it (in particular this is required if the
destination is a directory) otherwise seek in the file to get the size
of the file.
Add a new check that the size is a multiple of 2MiB otherwise the kernel
will reject it.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Check that if any device using vhost-user (net & disk with
vhost_user=true) or virtio-fs is enabled then check shared memory is
also enabled.
Fixes: #848
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The new 'shared' and 'hugepages' controls aim to replace the 'file'
option in MemoryConfig. This patch also updated all related integration
tests to use the new controls (instead of providing explicit paths to
"/dev/shm" or "/dev/hugepages").
Fixes: #1011
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Signed-off-by: Bo Chen <chen.bo@intel.com>
Currently unimplemented. Once implemented, this API will allow for
creating virtio-fs devices in the VM after it has booted.
Signed-off-by: Dean Sheather <dean@coder.com>
This ensures that the field is filled with None when it is not specified
as part of the deserialisation step.
Fixes: #1015
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This allows the validation of this requirement for both command line
booted VMs and those booted via the API.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This allows the validation of this requirement for both command line
booted VMs and those booted via the API.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Replace the existing VmConfig::valid() check with a call into
.validate() as part of earlier config setup or boot API checks.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The configuration comes from a variety of places (commandline, REST API
and restore) however some validation was only happening on the command
line parsing path. Therefore introduce a new ability to validate the
configuration before proceeding so that this can be used for commandline
and API boots.
For now move just the console and serial output mode validation under
the new validation API.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Now that the restore path uses RestoreConfig structure, we add a new
parameter called "prefault" to it. This will give the user the ability
to populate the pages corresponding to the mapped regions backed by the
snapshotted memory files.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The goal here is to move the restore parameters into a dedicated
structure that can be reused from the entire codebase, making the
addition or removal of a parameter easier.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The parse_size helper function can now be consolidated into the
ByteSized FromStr implementation.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Now all parsing code makes use of the Toggle and it's FromStr support
move the helper function into the from_str() implementation.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The integration tests and documentation make use of empty value strings
like "--net tap=" accept them but return None so that the default value
will be used as expected.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This simplifies the parsing of the option by using OptionParser along
with its automatic conversion behaviour.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Byte sizes are quantities ending in "K", "M", "G" and by implementing
this type with a FromStr implementation the values can be converted
using .parse().
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Before porting over to OptionParser add a unit test to validate the
current memory parsing code. This showed up a bug where the "size=" was
always required. Temporarily resolve this by assigning the string a
default value which will later be replaced when the code is refactored.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This will be used to simplify and consolidate much of the parsing code
used for command line parameters.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
currently unused, the initramfs argument is added to the cli,
and stored in vmm::config:VmConfig as an Option(InitramfsConfig(PathBuf))
Signed-off-by: Damjan Georgievski <gdamjan@gmail.com>
This commit adds new option hotplug_method to memory config.
It can set the hotplug method to "acpi" or "virtio-mem".
Signed-off-by: Hui Zhu <teawater@antfin.com>
This opens the backing file read-only, makes the pages in the mmap()
read-only and also makes the KVM mapping read-only. The file is also
mapped with MAP_PRIVATE to make the changes local to this process only.
This is functional alternative to having support for making a
virtio-pmem device readonly. Unfortunately there is no concept of
readonly virtio-pmem (or any type of NVDIMM/PMEM) in the Linux kernel so
to be able to have a block device that is appears readonly in the guest
requires significant specification and kernel changes.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
When using "--disk" with a vhost socket and not using self spawning then
it is not necessary or helpful to specify the path.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add the ability to specify the "id" associated with a device, by adding
an extra option to the parameter --device.
This new option is not mandatory, and by default, the VMM will take care
of finding a unique identifier.
If the identifier provided by the user through this new option is not
unique, an error will be thrown and the VM won't be started.
Fixes#881
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Add a new field to the DeviceConfig, allowing the VMM to allocate a name
to the VFIO devices.
By identifying a VFIO device with a unique name, we can make sure a user
can properly unplug it at any time.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Recently, vhost_user_block gained the ability of actively polling the
queue, a feature that can be disabled with the poll_queue property.
This change adds this property to DiskConfig, so it can be used
through the "disk" argument.
For the moment, it can only be used when vhost_user=true, but this
will change once virtio-block gets the poll_queue feature too.
Fixes: #787
Signed-off-by: Sergio Lopez <slp@redhat.com>
If no socket is supplied when enabling "vhost_user=true" on "--disk"
follow the "exe" path in the /proc entry for this process and launch the
network backend (via the vmm_path field.)
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
If no socket is supplied when enabling "vhost_user=true" on "--net"
follow the "exe" path in the /proc entry for this process and launch the
network backend (via the vmm_path field.)
Currently this only supports creating a new tap interface as the network
backend also only supports that.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add a socket and vhost_user parameter to this option so that the same
configuration option can be used for both virtio-block and
vhost-user-block. For now it is necessary to specify both vhost_user
and socket parameters as auto activation is not yet implemented. The wce
parameter for supporting "Write Cache Enabling" is also added to the
disk configuration.
The original command line parameter is still supported for now and will
be removed in a future release.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>