2005-12-19 16:34:11 +00:00
<?xml version="1.0"?>
<api name= 'libvir-python' >
2006-01-31 10:24:12 +00:00
<symbols >
<function name= "virConnectListDomainsID" file= 'python' >
<info > Returns the list of the ID of the domains on the hypervisor</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<return type= 'int *' info= "the list of ID or None in case of error" />
</function>
2006-11-16 00:17:10 +00:00
<function name= 'virConnectListDefinedDomains' file= 'python' >
<info > list the defined domains, stores the pointers to the names in @names</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<return type= 'str *' info= 'the list of Names of None in case of error' />
</function>
2007-03-09 15:42:50 +00:00
<function name= 'virConnectListNetworks' file= 'python' >
<info > list the networks, stores the pointers to the names in @names</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<return type= 'str *' info= 'the list of Names of None in case of error' />
</function>
<function name= 'virConnectListDefinedNetworks' file= 'python' >
<info > list the defined networks, stores the pointers to the names in @names</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<return type= 'str *' info= 'the list of Names of None in case of error' />
</function>
2006-02-24 12:26:56 +00:00
<function name= 'virDomainLookupByUUID' file= 'python' >
<info > Try to lookup a domain on the given hypervisor based on its UUID.</info>
<return type= 'virDomainPtr' info= 'a new domain object or NULL in case of failure' />
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<arg name= 'uuid' type= 'const unsigned char *' info= 'the UUID string for the domain, must be 16 bytes' />
</function>
2007-03-09 15:42:50 +00:00
<function name= 'virNetworkLookupByUUID' file= 'python' >
<info > Try to lookup a network on the given hypervisor based on its UUID.</info>
<return type= 'virNetworkPtr' info= 'a new network object or NULL in case of failure' />
<arg name= 'conn' type= 'virNetworkPtr' info= 'pointer to the hypervisor connection' />
<arg name= 'uuid' type= 'const unsigned char *' info= 'the UUID string for the network, must be 16 bytes' />
</function>
2006-03-29 12:46:03 +00:00
<function name= 'virDomainGetInfo' file= 'python' >
2008-03-14 11:08:03 +00:00
<info > Extract information about a domain. Note that if the connection used to get the domain is limited only a partial set of the information can be extracted.</info>
<return type= 'int *' info= 'the list of information or None in case of error' />
2006-01-31 10:24:12 +00:00
<arg name= 'domain' type= 'virDomainPtr' info= 'a domain object' />
</function>
2006-03-29 12:46:03 +00:00
<function name= 'virNodeGetInfo' file= 'python' >
2008-03-14 11:08:03 +00:00
<info > Extract hardware information about the Node.</info>
<return type= 'int *' info= 'the list of information or None in case of error' />
2006-03-29 12:46:03 +00:00
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
</function>
<function name= 'virDomainGetUUID' file= 'python' >
2006-02-23 11:26:17 +00:00
<info > Extract the UUID unique Identifier of a domain.</info>
<return type= 'char *' info= 'the 16 bytes string or None in case of error' />
<arg name= 'domain' type= 'virDomainPtr' info= 'a domain object' />
</function>
2008-06-10 15:20:25 +00:00
<function name= 'virDomainGetUUIDString' file= 'python' >
<info > Fetch globally unique ID of the domain as a string.</info>
<return type= 'char *' info= 'the UUID string or None in case of error' />
<arg name= 'pool' type= 'virDomainPtr' info= 'a domain object' />
</function>
2007-03-09 15:42:50 +00:00
<function name= 'virNetworkGetUUID' file= 'python' >
<info > Extract the UUID unique Identifier of a network.</info>
<return type= 'char *' info= 'the 16 bytes string or None in case of error' />
<arg name= 'domain' type= 'virNetworkPtr' info= 'a network object' />
</function>
2008-06-10 15:20:25 +00:00
<function name= 'virNetworkGetUUIDString' file= 'python' >
<info > Fetch globally unique ID of the network as a string.</info>
<return type= 'char *' info= 'the UUID string or None in case of error' />
<arg name= 'net' type= 'virNetworkPtr' info= 'a network object' />
</function>
<function name= 'virStoragePoolGetUUID' file= 'python' >
<info > Extract the UUID unique Identifier of a storage pool.</info>
<return type= 'char *' info= 'the 16 bytes string or None in case of error' />
<arg name= 'pool' type= 'virStoragePoolPtr' info= 'a storage pool object' />
</function>
<function name= 'virStoragePoolGetUUIDString' file= 'python' >
<info > Fetch globally unique ID of the storage pool as a string.</info>
<return type= 'char *' info= 'the UUID string or None in case of error' />
<arg name= 'pool' type= 'virStoragePoolPtr' info= 'a storage pool object' />
</function>
2007-04-10 23:15:58 +00:00
<function name= 'virNetworkGetAutostart' file= 'python' >
<info > Extract the autostart flag for a network.</info>
<return type= 'int' info= 'the autostart flag, or None in case of error' />
<arg name= 'domain' type= 'virNetworkPtr' info= 'a network object' />
</function>
<function name= 'virDomainGetAutostart' file= 'python' >
<info > Extract the autostart flag for a domain</info>
<return type= 'int' info= 'the autostart flag, or None in case of error' />
<arg name= 'domain' type= 'virDomainPtr' info= 'a network object' />
</function>
2008-06-11 07:49:01 +00:00
<function name= 'virStoragePoolGetAutostart' file= 'python' >
<info > Extract the autostart flag for a storage pool</info>
<return type= 'int' info= 'the autostart flag, or None in case of error' />
<arg name= 'pool' type= 'virStoragePoolPtr' info= 'a storage pool object' />
</function>
2007-09-30 20:52:13 +00:00
<function name= 'virDomainBlockStats' file= 'python' >
<info > Extracts block device statistics for a domain</info>
<return type= 'virDomainBlockStats' info= 'a tuple of statistics' />
<arg name= 'domain' type= 'virDomainPtr' info= 'a domain object' />
<arg name= 'path' type= 'char *' info= 'the path for the block device' />
</function>
<function name= 'virDomainInterfaceStats' file= 'python' >
<info > Extracts interface device statistics for a domain</info>
<return type= 'virDomainInterfaceStats' info= 'a tuple of statistics' />
<arg name= 'domain' type= 'virDomainPtr' info= 'a domain object' />
<arg name= 'path' type= 'char *' info= 'the path for the interface device' />
</function>
2007-12-07 08:41:01 +00:00
<function name= "virNodeGetCellsFreeMemory" file= 'python' >
2008-02-29 12:53:10 +00:00
<info > Returns the available memory for a list of cells</info>
2007-12-07 08:41:01 +00:00
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<arg name= 'startCell' type= 'int' info= 'first cell in the list' />
<arg name= 'maxCells' type= 'int' info= 'number of cell in the list' />
<return type= 'int *' info= "the list available memory in the cells" />
</function>
2008-01-21 15:41:15 +00:00
<function name= 'virDomainGetSchedulerParameters' file= 'python' >
<info > Get the scheduler parameters, the @params array will be filled with the values.</info>
<return type= 'int' info= '-1 in case of error, 0 in case of success.' />
<arg name= 'domain' type= 'virDomainPtr' info= 'pointer to domain object' />
</function>
<function name= 'virDomainGetSchedulerType' file= 'python' >
<info > Get the scheduler type.</info>
<return type= 'char *' info= 'NULL in case of error. The caller must free the returned string.' />
<arg name= 'domain' type= 'virDomainPtr' info= 'pointer to domain object' />
</function>
<function name= 'virDomainGetVcpus' file= 'python' >
<info > Extract information about virtual CPUs of domain, store it in info array and also in cpumaps if this pointer is' nt NULL.</info>
<return type= 'int' info= 'the number of info filled in case of success, -1 in case of failure.' />
<arg name= 'domain' type= 'virDomainPtr' info= 'pointer to domain object, or NULL for Domain0' />
</function>
<function name= 'virDomainPinVcpu' file= 'python' >
2008-02-29 12:53:10 +00:00
<info > Dynamically change the real CPUs which can be allocated to a virtual CPU. This function requires privileged access to the hypervisor.</info>
2008-01-21 15:41:15 +00:00
<return type= 'int' info= '0 in case of success, -1 in case of failure.' />
<arg name= 'domain' type= 'virDomainPtr' info= 'pointer to domain object, or NULL for Domain0' />
<arg name= 'vcpu' type= 'unsigned int' info= 'virtual CPU number' />
<arg name= 'cpumap' type= 'unsigned char *' info= 'pointer to a bit map of real CPUs (in 8-bit bytes) (IN) Each bit set to 1 means that corresponding CPU is usable. Bytes are stored in little-endian order: CPU0-7, 8-15... In each byte, lowest CPU number is least significant bit.' />
</function>
<function name= 'virDomainSetSchedulerParameters' file= 'python' >
<info > Change the scheduler parameters</info>
<return type= 'int' info= '-1 in case of error, 0 in case of success.' />
<arg name= 'domain' type= 'virDomainPtr' info= 'pointer to domain object' />
<arg name= 'params' type= 'virSchedParameterPtr' info= 'pointer to scheduler parameter objects' />
</function>
2008-05-29 14:53:58 +00:00
<function name= 'virConnectListStoragePools' file= 'python' >
<info > list the storage pools, stores the pointers to the names in @names</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<return type= 'str *' info= 'the list of Names of None in case of error' />
</function>
<function name= 'virConnectListDefinedStoragePools' file= 'python' >
<info > list the defined storage pool, stores the pointers to the names in @names</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<return type= 'str *' info= 'the list of Names of None in case of error' />
</function>
<function name= 'virStoragePoolListVolumes' file= 'python' >
<info > list the storage volumes, stores the pointers to the names in @names</info>
<arg name= 'pool' type= 'virStoragePoolPtr' info= 'pointer to the storage pool' />
<return type= 'str *' info= 'the list of Names of None in case of error' />
</function>
<function name= 'virStoragePoolGetInfo' file= 'python' >
<info > Extract information about a storage pool. Note that if the connection used to get the domain is limited only a partial set of the information can be extracted.</info>
<return type= 'int *' info= 'the list of information or None in case of error' />
<arg name= 'pool' type= 'virStoragePoolPtr' info= 'a storage pool object' />
</function>
<function name= 'virStorageVolGetInfo' file= 'python' >
<info > Extract information about a storage pool. Note that if the connection used to get the domain is limited only a partial set of the information can be extracted.</info>
<return type= 'int *' info= 'the list of information or None in case of error' />
<arg name= 'vol' type= 'virStorageVolPtr' info= 'a storage vol object' />
</function>
2008-11-21 12:41:15 +00:00
<function name= 'virNodeListDevices' file= 'python' >
<info > list the node devices</info>
<arg name= 'conn' type= 'virConnectPtr' info= 'pointer to the hypervisor connection' />
<arg name= 'cap' type= 'const unsigned char *' info= 'capability name' />
<arg name= 'flags' type= 'unsigned int' info= 'flags (unused; pass 0)' />
<return type= 'str *' info= 'the list of Names or None in case of error' />
</function>
<function name= 'virNodeDeviceListCaps' file= 'python' >
<info > list the node device's capabilities</info>
<arg name= 'dev' type= 'virNodeDevicePtr' info= 'pointer to the node device' />
<return type= 'str *' info= 'the list of Names or None in case of error' />
</function>
2006-01-31 10:24:12 +00:00
</symbols>
2005-12-19 16:34:11 +00:00