libvirt/tests/storagepoolxml2xmltest.c

107 lines
2.3 KiB
C
Raw Normal View History

#include <config.h>
#include <stdio.h>
#include <stdlib.h>
#include <unistd.h>
#include <string.h>
#include <sys/types.h>
#include <fcntl.h>
#include "internal.h"
#include "testutils.h"
#include "storage_conf.h"
#include "testutilsqemu.h"
#include "virstring.h"
#define VIR_FROM_THIS VIR_FROM_NONE
static int
testCompareXMLToXMLFiles(const char *inxml, const char *outxml)
{
char *inXmlData = NULL;
char *outXmlData = NULL;
char *actual = NULL;
int ret = -1;
virStoragePoolDefPtr dev = NULL;
if (virtTestLoadFile(inxml, &inXmlData) < 0)
goto fail;
if (virtTestLoadFile(outxml, &outXmlData) < 0)
goto fail;
if (!(dev = virStoragePoolDefParseString(inXmlData)))
goto fail;
if (!(actual = virStoragePoolDefFormat(dev)))
goto fail;
if (STRNEQ(outXmlData, actual)) {
virtTestDifference(stderr, outXmlData, actual);
goto fail;
}
ret = 0;
fail:
VIR_FREE(inXmlData);
VIR_FREE(outXmlData);
VIR_FREE(actual);
virStoragePoolDefFree(dev);
return ret;
}
static int
testCompareXMLToXMLHelper(const void *data)
{
int result = -1;
char *inxml = NULL;
char *outxml = NULL;
if (virAsprintf(&inxml, "%s/storagepoolxml2xmlin/%s.xml",
abs_srcdir, (const char*)data) < 0 ||
virAsprintf(&outxml, "%s/storagepoolxml2xmlout/%s.xml",
abs_srcdir, (const char*)data) < 0) {
goto cleanup;
}
result = testCompareXMLToXMLFiles(inxml, outxml);
cleanup:
VIR_FREE(inxml);
VIR_FREE(outxml);
return result;
}
static int
tests: simplify common setup A few of the tests were missing basic sanity checks, while most of them were doing copy-and-paste initialization (in fact, some of them pasted the argc > 1 check more than once!). It's much nicer to do things in one common place, and minimizes the size of the next patch that fixes getcwd usage. * tests/testutils.h (EXIT_AM_HARDFAIL): New define. (progname, abs_srcdir): Define for all tests. (VIRT_TEST_MAIN): Change callback signature. * tests/testutils.c (virtTestMain): Do more common init. * tests/commandtest.c (mymain): Simplify. * tests/cputest.c (mymain): Likewise. * tests/esxutilstest.c (mymain): Likewise. * tests/eventtest.c (mymain): Likewise. * tests/hashtest.c (mymain): Likewise. * tests/networkxml2xmltest.c (mymain): Likewise. * tests/nodedevxml2xmltest.c (myname): Likewise. * tests/nodeinfotest.c (mymain): Likewise. * tests/nwfilterxml2xmltest.c (mymain): Likewise. * tests/qemuargv2xmltest.c (mymain): Likewise. * tests/qemuhelptest.c (mymain): Likewise. * tests/qemuxml2argvtest.c (mymain): Likewise. * tests/qemuxml2xmltest.c (mymain): Likewise. * tests/qparamtest.c (mymain): Likewise. * tests/sexpr2xmltest.c (mymain): Likewise. * tests/sockettest.c (mymain): Likewise. * tests/statstest.c (mymain): Likewise. * tests/storagepoolxml2xmltest.c (mymain): Likewise. * tests/storagevolxml2xmltest.c (mymain): Likewise. * tests/virbuftest.c (mymain): Likewise. * tests/virshtest.c (mymain): Likewise. * tests/vmx2xmltest.c (mymain): Likewise. * tests/xencapstest.c (mymain): Likewise. * tests/xmconfigtest.c (mymain): Likewise. * tests/xml2sexprtest.c (mymain): Likewise. * tests/xml2vmxtest.c (mymain): Likewise.
2011-04-29 16:21:20 +00:00
mymain(void)
{
int ret = 0;
#define DO_TEST(name) \
if (virtTestRun("Storage Pool XML-2-XML " name, \
1, testCompareXMLToXMLHelper, (name)) < 0) \
ret = -1
DO_TEST("pool-dir");
DO_TEST("pool-fs");
DO_TEST("pool-logical");
DO_TEST("pool-logical-create");
DO_TEST("pool-disk");
DO_TEST("pool-iscsi");
DO_TEST("pool-iscsi-auth");
DO_TEST("pool-netfs");
DO_TEST("pool-scsi");
New XML attributes for storage pool source adapter This introduces 4 new attributes for storage pool source adapter. E.g. <adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/> Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults to 'scsi_host' if attribute 'name' is specified. I.e. It's optional for 'scsi_host' adapter, for back-compat reason. However, mandatory for 'fc_host' adapter and any new future adapter types. Attribute 'parent' is to specify the parent for the fc_host adapter. * docs/formatstorage.html.in: - Add documents for the 4 new attrs * docs/schemas/storagepool.rng: - Add RNG schema * src/conf/storage_conf.c: - Parse and format the new XMLs * src/conf/storage_conf.h: - New struct virStoragePoolSourceAdapter, replace "char *adapter" with it; - New enum virStoragePoolSourceAdapterType * src/libvirt_private.syms: - Export TypeToString and TypeFromString * src/phyp/phyp_driver.c: - Replace "adapter" with "adapter.data.name", which is member of the union of the new struct virStoragePoolSourceAdapter now. Later patch will add the checking, as "adapter.data.name" is only valid for "scsi_host" adapter. * src/storage/storage_backend_scsi.c: - Like above * tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml: * tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml: - New test for 'fc_host' and "scsi_host" adapter * tests/storagepoolxml2xmlout/pool-scsi.xml: - Change the expected output, as the 'type' defaults to 'scsi_host' if 'name" specified now * tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml: * tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml: - New test * tests/storagepoolxml2xmltest.c: - Include the test
2013-03-25 16:43:36 +00:00
DO_TEST("pool-scsi-type-scsi-host");
DO_TEST("pool-scsi-type-fc-host");
DO_TEST("pool-mpath");
DO_TEST("pool-iscsi-multiiqn");
DO_TEST("pool-iscsi-vendor-product");
DO_TEST("pool-sheepdog");
return ret==0 ? EXIT_SUCCESS : EXIT_FAILURE;
}
VIRT_TEST_MAIN(mymain)