qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
LC_ALL=C \
|
|
|
|
PATH=/bin \
|
2019-03-06 12:29:01 +00:00
|
|
|
HOME=/tmp/lib/domain--1-QEMUGuest2 \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
USER=test \
|
|
|
|
LOGNAME=test \
|
2019-03-08 11:15:07 +00:00
|
|
|
XDG_DATA_HOME=/tmp/lib/domain--1-QEMUGuest2/.local/share \
|
|
|
|
XDG_CACHE_HOME=/tmp/lib/domain--1-QEMUGuest2/.cache \
|
|
|
|
XDG_CONFIG_HOME=/tmp/lib/domain--1-QEMUGuest2/.config \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
QEMU_AUDIO_DRV=none \
|
|
|
|
/usr/bin/qemu-system-x86_64 \
|
|
|
|
-name QEMUGuest2 \
|
|
|
|
-S \
|
2018-03-29 10:51:55 +00:00
|
|
|
-machine pc-q35-2.7,accel=kvm,usb=off,dump-guest-core=off \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
-m 214 \
|
2019-04-12 08:03:36 +00:00
|
|
|
-realtime mlock=off \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
-smp 1,sockets=1,cores=1,threads=1 \
|
|
|
|
-uuid c7a5fdbd-edaf-9466-926a-d65c16db1809 \
|
2018-03-29 10:51:55 +00:00
|
|
|
-display none \
|
2018-03-29 10:51:55 +00:00
|
|
|
-no-user-config \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
-nodefaults \
|
2021-03-31 08:46:36 +00:00
|
|
|
-chardev socket,id=charmonitor,path=/tmp/lib/domain--1-QEMUGuest2/monitor.sock,server=on,wait=off \
|
2018-03-28 22:04:58 +00:00
|
|
|
-mon chardev=charmonitor,id=monitor,mode=control \
|
2018-03-29 10:51:55 +00:00
|
|
|
-rtc base=utc \
|
2018-03-29 10:51:55 +00:00
|
|
|
-no-shutdown \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
-no-acpi \
|
2021-03-31 08:46:36 +00:00
|
|
|
-device pcie-root-port,port=0x10,chassis=1,id=pci.1,bus=pcie.0,multifunction=on,addr=0x2 \
|
qemu: assign correct type of PCI address for vhost-scsi when using pcie-root
Commit 10c73bf1 fixed a bug that I had introduced back in commit
70249927 - if a vhost-scsi device had no manually assigned PCI
address, one wouldn't be assigned automatically. There was a slight
problem with the logic of the fix though - in the case of domains with
pcie-root (e.g. those with a q35 machinetype),
qemuDomainDeviceCalculatePCIConnectFlags() will attempt to determine
if the host-side PCI device is Express or legacy by examining sysfs
based on the host-side PCI address stored in
hostdev->source.subsys.u.pci.addr, but that part of the union is only
valid for PCI hostdevs, *not* for SCSI hostdevs. So we end up trying
to read sysfs for some probably-non-existent device, which fails, and
the function virPCIDeviceIsPCIExpress() returns failure (-1).
By coincidence, the return value is being examined as a boolean, and
since -1 is true, we still end up assigning the vhost-scsi device to
an Express slot, but that is just by chance (and could fail in the
case that the gibberish in the "hostside PCI address" was the address
of a real device that happened to be legacy PCI).
Since (according to Paolo Bonzini) vhost-scsi devices appear just like
virtio-scsi devices in the guest, they should follow the same rules as
virtio devices when deciding whether they should be placed in an
Express or a legacy slot. That's accomplished in this patch by
returning early with virtioFlags, rather than erroneously using
hostdev->source.subsys.u.pci.addr. It also adds a test case for PCIe
to assure it doesn't get broken in the future.
2017-12-15 16:42:35 +00:00
|
|
|
-device pcie-root-port,port=0x11,chassis=2,id=pci.2,bus=pcie.0,addr=0x2.0x1 \
|
2021-03-31 08:46:36 +00:00
|
|
|
-device vhost-scsi-pci,wwpn=naa.5123456789abcde0,vhostfd=3,id=hostdev0,bus=pci.1,addr=0x0
|