Commit Graph

10 Commits

Author SHA1 Message Date
Cole Robinson
c1c4d0d5a5 tests: qemuxml2xml: assign device addresses
We use the PreFormat callback for this. Many test cases need to be extended
to pass in proper qemuCaps flags so AssignAddresses doesn't throw errors.

One test case (pcie-root-port-too-many) is dropped, since it was meant
only for checking an error condition in qemuxml2argv, and one we add in
AssignAddresses it errors here too.

Long term I think AssignAddresses should be handled in qemu's PostParse
callback, but that's not entirely straightforward. Handling it here
means we can get the test suite churn over with.
2016-02-09 16:09:01 -05:00
Pavel Hrdina
36785c7e77 device: cleanup input device code
The current code was a little bit odd.  At first we've removed all
possible implicit input devices from domain definition to add them later
back if there was any graphics device defined while parsing XML
description.  That's not all, while formating domain definition to XML
description we at first ignore any input devices with bus different to
USB and VIRTIO and few lines later we add implicit input devices to XML.

This seems to me as a lot of code for nothing.  This patch may look
to be more complicated than original approach, but this is a preferred
way to modify/add driver specific stuff only in those drivers and not
deal with them in common parsing/formating functions.

The update is to add those implicit input devices into config XML to
follow the real HW configuration visible by guest OS.

There was also inconsistence between our behavior and QEMU's in the way,
that in QEMU there is no way how to disable those implicit input devices
for x86 architecture and they are available always, even without graphics
device.  This applies also to XEN hypervisor.  VZ driver already does its
part by putting correct implicit devices into live XML.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-01-26 17:53:33 +01:00
Ján Tomko
b33eb0dca1 qemu: auto-add pci-root controller for pc machine types
<controller type='pci' index='0' model='pci-root'/>
is auto-added to pc* machine types.
Without this controller PCI bus 0 is not available and
no PCI addresses are assigned by default.

Since older libvirt supported PCI bus 0 even without
this controller, it is removed from the XML when migrating.
2013-04-25 13:05:10 +02:00
Osier Yang
d70f2e117a numad: Always output 'placement' of <vcpu>
<vcpu> is not an optional node. The value for its 'placement'
actually always defaults to 'static' in the underlying codes.
(Even no 'cpuset' and 'placement' is specified, the domain
process will be pinned to all the available pCPUs).
2012-05-08 16:57:37 -06:00
Eric Blake
265457845f xml: output memory unit for clarity
Make it obvious to 'dumpxml' readers what unit we are using,
since our default of KiB for memory (1024) differs from qemu's
default of MiB; and differs from our use of bytes for storage.

Tests were updated via:

$ find tests/*data tests/*out -name '*.xml' | \
  xargs sed -i 's/<\(memory\|currentMemory\|hard_limit\|soft_limit\|min_guarantee\|swap_hard_limit\)>/<\1 unit='"'KiB'>/"
$ find tests/*data tests/*out -name '*.xml' | \
  xargs sed -i 's/<\(capacity\|allocation\|available\)>/<\1 unit='"'bytes'>/"

followed by a few fixes for the stragglers.

Note that with this patch, the RNG for <memory> still forbids
validation of anything except unit='KiB', since the code silently
ignores the attribute; a later patch will expand <memory> to allow
scaled input in the code and update the RNG to match.

* docs/schemas/basictypes.rng (unit): Add 'bytes'.
(scaledInteger): New define.
* docs/schemas/storagevol.rng (sizing): Use it.
* docs/schemas/storagepool.rng (sizing): Likewise.
* docs/schemas/domaincommon.rng (memoryKBElement): New define; use
for memory elements.
* src/conf/storage_conf.c (virStoragePoolDefFormat)
(virStorageVolDefFormat): Likewise.
* src/conf/domain_conf.h (_virDomainDef): Document unit used
internally.
* src/conf/storage_conf.h (_virStoragePoolDef, _virStorageVolDef):
Likewise.
* tests/*data/*.xml: Update all tests.
* tests/*out/*.xml: Likewise.
* tests/define-dev-segfault: Likewise.
* tests/openvzutilstest.c (testReadNetworkConf): Likewise.
* tests/qemuargv2xmltest.c (blankProblemElements): Likewise.
2012-03-07 18:24:43 -07:00
Osier Yang
4288b22fb2 conf: Introduce new attribute for device address format
* src/conf/domain_conf.h: Add new member "target" to struct
  _virDomainDeviceDriveAddress.

* src/conf/domain_conf.c: Parse and format "target"

* Lots of tests (.xml) in tests/domainsnapshotxml2xmlout,
  tests/qemuxml2argvdata, tests/qemuxml2xmloutdata, and
  tests/vmx2xmldata/ are modified for newly introduced
  attribute "target" for address of "drive" type.
2012-02-28 14:27:11 +08:00
Marc-André Lureau
42043afcdc domain: add implicit USB controller
Some tools, such as virt-manager, prefers having the default USB
controller explicit in the XML document. This patch makes sure there
is one. With this patch, it is now possible to switch from USB1 to
USB2 from the release 0.9.1 of virt-manager.

Fix tests to pass with this change.
2012-02-09 16:44:57 -07:00
Matthias Bolte
d9ad8ac392 Add VIR_DIV_UP to divide memory or storage request sizes with round up
Use it in all places where a memory or storage request size is converted
to a larger granularity. This avoids requesting too small memory or storage
sizes that could result from the truncation done by a simple division.

This extends the round up fix in 6002e0406c
to the whole codebase.

Instead of reporting errors for odd values in the VMX code round them up.

Update the QEMU Argv tests accordingly as the original memory size 219200
isn't a even multiple of 1024 and is rounded up to 215 megabyte now. Change
it to 219100 and 219136. Use two different values intentionally to make
sure that rounding up works.

Update virsh.pod accordingly, as rounding down and rejecting are replaced
by rounding up.
2011-01-29 00:42:10 +01:00
Cole Robinson
6b24755235 domain conf: Track <console> target type
All <console> devices now export a <target> type attribute. QEMU defaults
to 'serial', UML defaults to 'uml, xen can be either 'serial' or 'xen'
depending on fullvirt. Understandably there is lots of test fallout.

This will be used to differentiate between a serial vs. virtio console for
QEMU.

Signed-off-by: Cole Robinson <crobinso@redhat.com>
2010-07-28 16:47:59 -04:00
Cole Robinson
b2a4a383d3 tests: Test qemuxml2xml when expected xml changes
Add tests for auto memballon, implicit IDE, SCSI, virtio channel
controllers, and console/serial back compat.

Additionally, an explicit qemuxml2argvtest for scsi disks is added.

Signed-off-by: Cole Robinson <crobinso@redhat.com>
2010-07-28 16:47:56 -04:00