Reuse the vshBlockJobWait infrastructure to refactor cmdBlockCommit to
use the common code. This additionally fixes a bug when working with
new qemus, where when doing an active commit with --pivot the pivoting
would fail, since qemu reaches 100% completion but the job doesn't
switch to synchronized phase right away.
Introduce helper function that will provide logic for waiting for block
job completion so the 3 open coded places can be unified and improved.
This patch introduces the whole logic and uses it to fix
cmdBlockJobPull. The vshBlockJobWait function provides common logic for
block job waiting that should be robust enough to work across all
previous versions of libvirt. Since virsh allows passing user-provided
strings as paths of block devices we can't reliably use block job events
for detection of block job states so the function contains a great deal
of fallback logic.
Use the VSH_EXCLUSIVE_OPTIONS to exclude combinations of --pivot and
--keep-overlay and refactor the enforcing of the --wait option and other
flags that imply --wait.
Use the VSH_EXCLUSIVE_OPTIONS_VAR to interlock incompatible options.
Since a variable named 'abort' would conflict with older compilers use
VSH_EXCLUSIVE_OPTIONS for the --abort option.
Commit ed8155eafb documented that
mhz field in virNodeInfo might be 0 if the frequency is unknown. Modify
virsh to know about that.
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
Some drivers don't expose available huge page sizes in the
capabilities XML. For instance, LXC driver is one of those.
This has a downside that when virsh is trying to get
aggregated info on free pages per all NUMA nodes, it fails.
The problem is that the virNodeGetFreePages() API expects
caller to pass an array of page sizes he is interested in.
In virsh, this array is filled from the capabilities from
'/capabilities/host/cpu/pages' XPath. As said, in LXC
there's no such XPath and therefore virsh fails currently.
But hey, we can fallback: the page sizes are exposed under
'/capabilities/host/topology/cells/cell/pages'. The page
size can be collected from there, and voilà the command
works again. But now we must make sure that there are no
duplicates in the array passed to the public API. Otherwise
we won't get as beautiful output as we are getting now.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
There's this condition:
flags & VIR_DOMAIN_AFFECT_CURRENT && virDomainIsActive(dom)
which can never be true since VIR_DOMAIN_AFFECT_CURRENT has hardcoded
value of zero. Therefore virDomainIsActive() is a dead code. However,
the condition could make sense if it is rewritten as the following:
!(flags & VIR_DOMAIN_AFFECT_CONFIG) && virDomainIsActive(dom)
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Commit id '81dd81e' caused a regression when attempting to print a
specific vcpuid that is out of the range of the maximum vcpus for
the guest, such as:
$ virsh vcpupin $dom 1000
VCPU: CPU Affinity
----------------------------------
$
Rather than just recover the old message, let's adjust the message based
on what would be displayed for a similar failure in the set path, such as:
$ virsh vcpupin $dom 1000
error: vcpu 1000 is out of range of persistent cpu count 2
$ virsh vcpupin $dom 1000 --live
error: vcpu 1000 is out of range of live cpu count 2
$
Signed-off-by: Luyao Huang <lhuang@redhat.com>
This patch provides support for a new watchdog action "inject-nmi" which
allows to define an inject of a non-maskable interrupt into a guest.
Signed-off-by: Boris Fiuczynski <fiuczy@linux.vnet.ibm.com>
Reviewed-by: Daniel Hansel <daniel.hansel@linux.vnet.ibm.com>
Reviewed-by: Stefan Zimmermann <stzi@linux.vnet.ibm.com>
Reviewed-by: Tony Krowiak <akrowiak@linux.vnet.ibm.com>
The SCSI Architecture Model defines a logical unit address
as 64-bits in length, so change the field accordingly so
that the entire value could be stored.
Signed-off-by: Eric Farman <farman@linux.vnet.ibm.com>
The address elements are all unsigned integers, so we should
use the appropriate print directive when printing it.
Signed-off-by: Eric Farman <farman@linux.vnet.ibm.com>
The SCSI address element attributes bus, target, and unit are expected
to be positive values, so make sure no one provides a negative value since
the value is stored as an unsigned.
Signed-off-by: Eric Farman <farman@linux.vnet.ibm.com>
When the block job would fail while watching it using the "--wait"
option for blockcopy, virsh would rather unhelpfully report:
$ virsh blockcopy vm hdc /tmp/raw.img --granularity 4096 --verbose --wait
Now in mirroring phase
Add a special case when the block job vanishes while waiting for it to
finish to improve the message:
$ virsh blockcopy vm hdc /tmp/raw.img --granularity 8192 --verbose --wait
error: Block Copy unexpectedly failed
Add `virsh migrate' option `--migrate-disks' that allows CLI user to
explicitly specify block devices to migrate.
Signed-off-by: Pavel Boldin <pboldin@mirantis.com>
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
You had only one job. That's what you can say about this example
binary. In future, parts of virsh that are usable for this binary
should be split into separate shell-utils and virt-admin should gain all
the cool features of virsh without too much code addition.
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
When reviewing some network patches, I've noticed we don't have
those switches to the 'net-list' command. We should. They are
merely copied over from 'list' command.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Instead of sticking to old code pattern use the one laid out by
cmdList. Use FILTER() macro instead of series of boolean
variables.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
In the pre-NUMA ages pinning a vCPU to all pCPUs was eaqual to deleting
the pinning info. Now it does not entirely work that way. Pinning a vCPU
to all pCPUs might be a desired operation. Additionally removal of the
pinning will result into using the default pinning information at the
next boot which might be different from all vcpus.
This patch removes the false assumption that we should remove the
pinning after pinning to all vCPUs and tweaks the documentation for
virsh.
A later patch will implement a new flag for the virDomainPinVcpuFlags
API that will allow to remove the pinning in a sane way.
When watching a job (save, managedsave, dump, migrate) virsh spawns a
thread to call the appropriate API and waits for the result while
watching for interruption signals (SIGINT, Ctrl-C on the terminal).
Whenever such signal is caught, virsh calls virDomainAbortJob, stops
waiting for the job, and returns the result of virDomainAbortJob.
This is wrong because the job might have finished in the meantime or it
might have been cancelled by someone else and virsh would just report
the failure to abort the job. However, we are not interested in the
virDomainAbortJob's result at all, we need to keep waiting for the main
job to finish and report its result instead.
https://bugzilla.redhat.com/show_bug.cgi?id=1131755
Signed-off-by: Jiri Denemark <jdenemar@redhat.com>
This will allow us to use vshError() to report errors from inside
vshCommandOpt*(), instead of replicating the same logic and error
messages all over the place.
We also have more context inside the vshCommandOpt*() functions,
for example the actual value used on the command line, which means
we can produce more detailed error messages.
vshCommandOptBool() is the exception here, because it's explicitly
designed not to report any error.
When shrinking a volume by a certain size, instead of typing
vol-resize volume 1G --delta --shrink
we allow the convience of specifying a negative value:
vol-resize volume -1G --delta --shrink
getting the same results with one more character.
A negative value only makes sense as a delta. Imply the
--delta parameter if the value is negative.
Still require --shrink, because the operation is potentially
destructive.
https://bugzilla.redhat.com/show_bug.cgi?id=1224088
commit id 'bd00e00e' neglected to add the new adapter source options
into the if condition that allowed printing the <source> XML fields.
The <adapter type='fc_host'.../> doesn't require other options in order
to be complete.
Some virsh commands have a size parameter, which is handled as scaled
integer. We don't have any *feature* that would allow to use '-1' as
maximum size, so it's safe to reject any negative values for those
commands.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1159171
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
The option didn't have VSH_OT_INT type even thought it's expected
to be numeric, as shown by the fact that vshCommandOptInt() is later
used to retrieve its value.
Replace more than 30 ad-hoc error messages with a single, generic one
that contains the name of the option being processed and some hints
to help the user understand what could have gone wrong.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1207043
When parsing a cpulist, the virBitmapParse is used. On an invalid
bitmap an error is reported, but the error gets cleared
immediately by subsequent public APIs call, e.g. virDomainFree().
Moreover, we don't check whether bitmap fits into maximal CPU ID
on the host. Therefore the following examples failed without any
error:
# virsh vcpupin test3 1 aaa
# virsh vcpupin test3 1 1000
Signed-off-by: Luyao Huang <lhuang@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1191227
Since 0fa15b19 we have this variable SYNC_TIME which allows users to
synchronize time on domain resume. However, despite what documentation
says, it's by default on because it's never initialized. Fix this by
setting it to zero at the beginning of the libvirt-guests script.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Extend it to a universal helper used for clearing lists of any objects.
Note that the argument type is specifically void * to allow implicit
typecasting.
Additionally add a helper that works on non-NULL terminated arrays once
we know the length.
The --maximum option wasn't properly parsed and the equivalent flag
wasn't set. Fix this bug and also rewrite the way we check this option
by using new macro. The new approach is that --maximum requires
--config, no other combination is allowed, because they don't make sense.
The new error will be:
# virsh setvcpus test --maximum 10
error: Option --config is required by option --maximum
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1204033
Signed-off-by: Luyao Huang <lhuang@redhat.com>
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1161617
Add command to allow adding and removing IOThreads from the domain including
the configuration and live domain.
$ virsh iothreadadd --help
NAME
iothreadadd - add an IOThread to the guest domain
SYNOPSIS
iothreadadd <domain> <id> [--config] [--live] [--current]
DESCRIPTION
Add an IOThread to the guest domain.
OPTIONS
[--domain] <string> domain name, id or uuid
[--id] <number> iothread for the new IOThread
--config affect next boot
--live affect running domain
--current affect current domain
$ virsh iothreaddel --help
NAME
iothreaddel - delete an IOThread from the guest domain
SYNOPSIS
iothreaddel <domain> <id> [--config] [--live] [--current]
DESCRIPTION
Delete an IOThread from the guest domain.
OPTIONS
[--domain] <string> domain name, id or uuid
[--id] <number> iothread_id for the IOThread to delete
--config affect next boot
--live affect running domain
--current affect current domain
Assuming a running $dom with multiple IOThreads assigned and that
that the $dom has disks assigned to IOThread 1 and IOThread 2:
$ virsh iothreadinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
$ virsh iothreadadd $dom 1
error: invalid argument: an IOThread is already using iothread_id '1' in iothreadpids
$ virsh iothreadadd $dom 1 --config
error: invalid argument: an IOThread is already using iothread_id '1' in persistent iothreadids
$ virsh iothreadadd $dom 4
$ virsh iothreadinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
4 0-3
$ virsh iothreadinfo $dom --config
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
$ virsh iothreadadd $dom 4 --config
$ virsh iothreadinfo $dom --config
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
4 0-3
Assuming the same original configuration
$ virsh iothreaddel $dom 1
error: invalid argument: cannot remove IOThread 1 since it is being used by disk 'vde'
$ virsh iothreaddel $dom 3
$ virsh iothreadinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
$ virsh iothreadinfo $dom --config
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1