There's this condition:
flags & VIR_DOMAIN_AFFECT_CURRENT && virDomainIsActive(dom)
which can never be true since VIR_DOMAIN_AFFECT_CURRENT has hardcoded
value of zero. Therefore virDomainIsActive() is a dead code. However,
the condition could make sense if it is rewritten as the following:
!(flags & VIR_DOMAIN_AFFECT_CONFIG) && virDomainIsActive(dom)
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Commit id '81dd81e' caused a regression when attempting to print a
specific vcpuid that is out of the range of the maximum vcpus for
the guest, such as:
$ virsh vcpupin $dom 1000
VCPU: CPU Affinity
----------------------------------
$
Rather than just recover the old message, let's adjust the message based
on what would be displayed for a similar failure in the set path, such as:
$ virsh vcpupin $dom 1000
error: vcpu 1000 is out of range of persistent cpu count 2
$ virsh vcpupin $dom 1000 --live
error: vcpu 1000 is out of range of live cpu count 2
$
Signed-off-by: Luyao Huang <lhuang@redhat.com>
This patch provides support for a new watchdog action "inject-nmi" which
allows to define an inject of a non-maskable interrupt into a guest.
Signed-off-by: Boris Fiuczynski <fiuczy@linux.vnet.ibm.com>
Reviewed-by: Daniel Hansel <daniel.hansel@linux.vnet.ibm.com>
Reviewed-by: Stefan Zimmermann <stzi@linux.vnet.ibm.com>
Reviewed-by: Tony Krowiak <akrowiak@linux.vnet.ibm.com>
The SCSI Architecture Model defines a logical unit address
as 64-bits in length, so change the field accordingly so
that the entire value could be stored.
Signed-off-by: Eric Farman <farman@linux.vnet.ibm.com>
The address elements are all unsigned integers, so we should
use the appropriate print directive when printing it.
Signed-off-by: Eric Farman <farman@linux.vnet.ibm.com>
The SCSI address element attributes bus, target, and unit are expected
to be positive values, so make sure no one provides a negative value since
the value is stored as an unsigned.
Signed-off-by: Eric Farman <farman@linux.vnet.ibm.com>
When the block job would fail while watching it using the "--wait"
option for blockcopy, virsh would rather unhelpfully report:
$ virsh blockcopy vm hdc /tmp/raw.img --granularity 4096 --verbose --wait
Now in mirroring phase
Add a special case when the block job vanishes while waiting for it to
finish to improve the message:
$ virsh blockcopy vm hdc /tmp/raw.img --granularity 8192 --verbose --wait
error: Block Copy unexpectedly failed
Add `virsh migrate' option `--migrate-disks' that allows CLI user to
explicitly specify block devices to migrate.
Signed-off-by: Pavel Boldin <pboldin@mirantis.com>
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
When watching a job (save, managedsave, dump, migrate) virsh spawns a
thread to call the appropriate API and waits for the result while
watching for interruption signals (SIGINT, Ctrl-C on the terminal).
Whenever such signal is caught, virsh calls virDomainAbortJob, stops
waiting for the job, and returns the result of virDomainAbortJob.
This is wrong because the job might have finished in the meantime or it
might have been cancelled by someone else and virsh would just report
the failure to abort the job. However, we are not interested in the
virDomainAbortJob's result at all, we need to keep waiting for the main
job to finish and report its result instead.
https://bugzilla.redhat.com/show_bug.cgi?id=1131755
Signed-off-by: Jiri Denemark <jdenemar@redhat.com>
This will allow us to use vshError() to report errors from inside
vshCommandOpt*(), instead of replicating the same logic and error
messages all over the place.
We also have more context inside the vshCommandOpt*() functions,
for example the actual value used on the command line, which means
we can produce more detailed error messages.
vshCommandOptBool() is the exception here, because it's explicitly
designed not to report any error.
Replace more than 30 ad-hoc error messages with a single, generic one
that contains the name of the option being processed and some hints
to help the user understand what could have gone wrong.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1207043
When parsing a cpulist, the virBitmapParse is used. On an invalid
bitmap an error is reported, but the error gets cleared
immediately by subsequent public APIs call, e.g. virDomainFree().
Moreover, we don't check whether bitmap fits into maximal CPU ID
on the host. Therefore the following examples failed without any
error:
# virsh vcpupin test3 1 aaa
# virsh vcpupin test3 1 1000
Signed-off-by: Luyao Huang <lhuang@redhat.com>
The --maximum option wasn't properly parsed and the equivalent flag
wasn't set. Fix this bug and also rewrite the way we check this option
by using new macro. The new approach is that --maximum requires
--config, no other combination is allowed, because they don't make sense.
The new error will be:
# virsh setvcpus test --maximum 10
error: Option --config is required by option --maximum
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1204033
Signed-off-by: Luyao Huang <lhuang@redhat.com>
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1161617
Add command to allow adding and removing IOThreads from the domain including
the configuration and live domain.
$ virsh iothreadadd --help
NAME
iothreadadd - add an IOThread to the guest domain
SYNOPSIS
iothreadadd <domain> <id> [--config] [--live] [--current]
DESCRIPTION
Add an IOThread to the guest domain.
OPTIONS
[--domain] <string> domain name, id or uuid
[--id] <number> iothread for the new IOThread
--config affect next boot
--live affect running domain
--current affect current domain
$ virsh iothreaddel --help
NAME
iothreaddel - delete an IOThread from the guest domain
SYNOPSIS
iothreaddel <domain> <id> [--config] [--live] [--current]
DESCRIPTION
Delete an IOThread from the guest domain.
OPTIONS
[--domain] <string> domain name, id or uuid
[--id] <number> iothread_id for the IOThread to delete
--config affect next boot
--live affect running domain
--current affect current domain
Assuming a running $dom with multiple IOThreads assigned and that
that the $dom has disks assigned to IOThread 1 and IOThread 2:
$ virsh iothreadinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
$ virsh iothreadadd $dom 1
error: invalid argument: an IOThread is already using iothread_id '1' in iothreadpids
$ virsh iothreadadd $dom 1 --config
error: invalid argument: an IOThread is already using iothread_id '1' in persistent iothreadids
$ virsh iothreadadd $dom 4
$ virsh iothreadinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
4 0-3
$ virsh iothreadinfo $dom --config
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
$ virsh iothreadadd $dom 4 --config
$ virsh iothreadinfo $dom --config
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
4 0-3
Assuming the same original configuration
$ virsh iothreaddel $dom 1
error: invalid argument: cannot remove IOThread 1 since it is being used by disk 'vde'
$ virsh iothreaddel $dom 3
$ virsh iothreadinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
$ virsh iothreadinfo $dom --config
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
virDomainGetJobStats is able to report statistics of a completed
migration, however to get usable downtime and total time statistics both
hosts have to keep synchronized time. To provide at least some
estimation of the times even when NTP daemons are not running on both
hosts we can just ignore the time needed to transfer a migration cookie
to the destination host. The result will be also inaccurate but a bit
more predictable. The total/down time will just be at least what we
report.
https://bugzilla.redhat.com/show_bug.cgi?id=1213434
Commit a0670ae caused a regression in 'virsh event' and
'virsh qemu-monitor-event' - if a user tries to filter the
command to a specific domain, an error message is printed:
$ virsh event dom --loop
error: internal error: virsh qemu-monitor-event: no domain VSH_OT_DATA option
and then the command continues as though no domain had been
supplied (giving events for ALL domains, instead of the
requested one). This is because the code was incorrectly
assuming that all "domain" options would be supplied via a
mandatory VSH_OT_DATA, even though "domain" is optional for
these two commands, so we had changed them to VSH_OT_STRING
to quit failing for other reasons (ever since it was decided
that VSH_OT_DATA and VSH_OT_STRING should no longer be
synonyms).
In looking at the situation, though, the code for looking up
a domain was making a pointless check for whether the option
exists prior to finding the option's string value, as
vshCommandOptStringReq does just fine at reporting any errors
when looking up a string whether or not the option was present.
So this is a case of regression fixing by pure code deletion :)
* tools/virsh-domain.c (vshCommandOptDomainBy): Drop useless filter.
* tools/virsh-interface.c (vshCommandOptInterfaceBy): Likewise.
* tools/virsh-network.c (vshCommandOptNetworkBy): Likewise.
* tools/virsh-nwfilter.c (vshCommandOptNWFilterBy): Likewise.
* tools/virsh-secret.c (vshCommandOptSecret): Likewise.
* tools/virsh.h (vshCmdHasOption): Drop unused function.
* tools/virsh.c (vshCmdHasOption): Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
When set guest memory with a invalid parameter of --soft-limit,
it posts weird error:
$ virsh memtune r7 --hard-limit 20417224 --soft-limit 9007199254740992 \
--swap-hard-limit 35417224
error: Unable to parse integer parameter 'NAME
Change it to
error: Unable to parse integer parameter soft-limit
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1211550
Signed-off-by: Shanzhi Yu <shyu@redhat.com>
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Use virBitmapDataToString instead of constructing the ranges bit
by bit, remove the checking of parameters (that is already done
by the callers).
Let the callers choose the right bitmap, since there's only
one that uses this helper on a matrix-in-an-array.
$ sudo virsh change-media f19 hdc /mnt/data/devel/media/Fedora-16-x86_64-Live-KDE.iso
succeeded to complete action update on media
Change the message to:
Successfully {inserted,ejected,changed} media.
https://bugzilla.redhat.com/show_bug.cgi?id=967946
The overflow check for the bandwidth parameter did not jump to the
cleanup label.
Additionally virsh should use vshError instead of virReportError.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1206987
Signed-off-by: Luyao Huang <lhuang@redhat.com>
The command did not modify the disk type and thus didn't allow to change
media from a file image to a block backed image or vice versa. In
addition when operating on a network backed removable devices the
command would replace the while <source> subelement with an invalid one.
This patch adds the --block option that allows to specify that the new
image is block backed and assumes that without that option all images
are file backed. Since network backends were always mangled it should
not cause problems.
Since cmdDetachDisk() calls into vshPrepareDiskXML() with
type == VSH_PREPARE_DISK_XML_NONE && source == NULL this would result
into skipping all the checks and effectively turn the function into a
XML formatter.
This patch changes the code to use the formatter directly so that the
function can be refactored in a easier way.
Commit f182da20 (v1.2.6) caused a slight regression in virsh
reporting of a non-active block job; where it used to state
"Commit complete", it now states "Now in synchronized phase".
But the synchronized phase is only possible for an active commit.
For a reproducer, I created a chain 'a <- b <- c <- d <- e' and
ran virsh blockcommit $dom vda --top c --base a --verbose --wait
* tools/virsh-domain.c (cmdBlockCommit): Synchronized phase is
only possible on active commits.
Signed-off-by: Eric Blake <eblake@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1135491
$ virsh iothread --help
NAME
iothreadpin - control domain IOThread affinity
SYNOPSIS
iothreadpin <domain> <iothread> <cpulist> [--config] [--live] [--current]
DESCRIPTION
Pin domain IOThreads to host physical CPUs.
OPTIONS
[--domain] <string> domain name, id or uuid
[--iothread] <number> IOThread ID number
[--cpulist] <string> host cpu number(s) to set
--config affect next boot
--live affect running domain
--current affect current domain
Using the output from iothreadsinfo, allow changing the pinned CPUs for
a single IOThread.
$ virsh iothreadsinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-1
$ virsh iothreadpin $dom 3 0-2
Then view the change
$ virsh iothreadsinfo $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0-2
If an invalid value is supplied or require option missing,
then an error will be displayed:
$ virsh iothreadpin $dom 4 3
error: invalid argument: iothread value out of range 4 > 3
$ virsh iothreadpin $dom 3
error: command 'iothreadpin' requires <cpulist> option
Add the 'iothreadsinfo' command to display IOThread Info data. Allow for
[--live] or [--config] options in order to display live or config data
for an active domain.
$ virsh iothreadsinfo --help
NAME
iothreadsinfo - view domain IOThreads
SYNOPSIS
iothreadsinfo <domain> [--config] [--live] [--current]
DESCRIPTION
Returns basic information about the domain IOThreads.
OPTIONS
[--domain] <string> domain name, id or uuid
--config affect next boot
--live affect running domain
--current affect current domain
An active domain may return:
$ virsh iothreads $dom
IOThread ID CPU Affinity
---------------------------------------------------
1 2
2 3
3 0
$ echo $?
0
For domains which don't have IOThreads the following is returned:
$ virsh iothreads $dom
No IOThreads found for the domain
$ echo $?
0
For domains which are not running the following is returned:
$ virsh iothreads $dom --live
error: Unable to get domain IOThreads information
error: Requested operation is not valid: domain is not running
$ echo $?
1
Editing a domains configuration and modifying the iothreadpin data for
thread 3 from nothing provided to setting a cpuset of '0-1' and then
displaying using --config would display:
$ virsh iothreads f18iothr --config
IOThread ID CPU Affinity
----------------------------
1 2
2 3
3 0-1
$
Signed-off-by: John Ferlan <jferlan@redhat.com>
Fix vshMemtuneGetSize to return correct value. We can then decide
according that return code whether a parameter is present and valid or
not. This will allow as to accept 0 as a valid value.
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
The "virDomainGetInfo" will get for running domain only live info and for
offline domain only config info. There was no way how to get config info
for running domain. We will use "vshCPUCountCollect" instead to get the
correct cpu count that we need to pass to "virDomainGetVcpuPinInfo".
Also cleanup some unnecessary variables and checks that are done by
drivers.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1160559
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
When editing a domain with 'virsh edit' and failing validation, the
usual message pops up:
Failed. Try again? [y,n,f,?]:
Turning off validation can be useful, mainly for testing (but other
purposes too), so this patch adds support for relaxing definition in
virsh-edit and makes 'virsh edit <domain>' more usable.
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
Our hotplug code supports macvtap insertion to guests. However, we
somehow forgot about 'attach-interface' (which tries to build XML from
passed arguments and use virDomainAttachDeviceFlags()).
New type is accessible under 'direct' type, to keep the same type as
used in domain XML.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Instead of verbose string to enum conversion (if STREQ() else if
STREQ() else if STREQ() ...) lets use virDomainNetType{From,To}String.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
The type of interface to attach is held in the variable 'typ'.
Depending on interface type selected by user, the variable is set
either to 1 (network), or 2 (bridge). Lets use already existing
enum from domain_conf.h instead: virDomainNetType.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1191016
virsh's domdisplay command looks in /domain/devices/graphics/@listen
of the domain's XML for the listen address, however for listen
type='network' (added in libvirt 0.9.4), the <graphics> element
doesn't have a listen attribute, but has a <listen> subelement,
*still* with no address (this is the inactive XML):
<graphics type='spice' autoport='yes' keymap='en-us'>
<listen type='network' network='default'/>
</graphics>
However, at domain start time the <listen> subelement gets its address
attribute filled in once libvirt figures out the IP address associated
with the named network (this is the status XML):
<graphics type='spice' port='5901' autoport='yes' keymap='en-us'>
<listen type='network' address='192.168.122.1' network='default'/>
</graphics>
So in these cases, we need to look at
/domain/devices/graphics/listen/@address instead.
Even though another patch is being pushed that will backfill
listen/@address into @listen, this patch is still useful, as it fixes
domdisplay for cases of a new virsh (with this patch) connecting to a
libvirtd that is newer than 0.9.4 but doesn't have the followup patch.
Signed-off-by: Luyao Huang <lhuang@redhat.com>
Signed-off-by: Laine Stump <laine@laine.org>
Adding ccw bus address support to the optional address parameter of virsh
attach-disk. The format used is ccw:cssid. ssid.devno, e.g.
ccw:0xfe.0x0.0x0201
Virtio-ccw devices must have their cssid set to 0xfe.
Signed-off-by: Stefan Zimmermann <stzi@linux.vnet.ibm.com>
Reviewed-by: Boris Fiuczynski <fiuczy@linux.vnet.ibm.com>
Reviewed-by: Cornelia Huck <cornelia.huck@de.ibm.com>