IGMP is used on IPv4 networks tp setup multicast group memberships. On
IPv6, this job is done by Multicast Listener Discovery (MLD), which
uses ICMPv6 packets rather than its own IP protocol number like IGMP.
The nwfilter documentation lists "igmp-ipv6" as one of the possible
protocols, but this is ignored (and stripped from the xml). This patch
removes that erroneous reference.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1038888
Since commit f5d9c5d00c moved the virTypedParam stuff into
libvirt-common we did not generate any docs for them and neither did we
populate them into libvirt-api.xml. This broke the sanity check in
libvirt python. Fix it by generating docs for libvirt-common.h too.
Some macros don't make sense to be documented at all. Add infrastructure
to the web/api generator and add VIR_DEPRECATED and VIR_EXPORT_VAR as
macros we should not document.
Our uninstall script is not exact counterpart of install one.
Therefore we are leaving couple of files behind. This should not
happen.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
While we could leave it behind as an indelible sign that libvirt
has been running on host, other users might not be that fond of
it.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Ploop image consists of directory with two files: ploop image itself,
called root.hds and DiskDescriptor.xml that contains information about
ploop device: https://openvz.org/Ploop/format.
Such volume are difficult to manipulate in terms of existing volume types
because they are neither a single files nor a directory.
This patch introduces new volume type - ploop. This volume type is used
by ploop volume's exclusively.
Signed-off-by: Olga Krishtal <okrishtal@virtuozzo.com>
Signed-off-by: Ján Tomko <jtomko@redhat.com>
This controller provides a single PCIe port on a new root. It is
similar to pci-expander-bus, intended to provide a bus that can be
associated with a guest-identifiable NUMA node, but is for
machinetypes with PCIe rather than PCI (e.g. q35-based machinetypes).
Aside from PCIe vs. PCI, the other main difference is that a
pci-expander-bus has a companion pci-bridge that is automatically
attached along with it, but pcie-expander-bus has only a single port,
and that port will only connect to a pcie-root-port, or to a
pcie-switch-upstream-port. In order for the bus to be of any use in
the guest, it must have either a pcie-root-port or a
pcie-switch-upstream-port attached (and one or more
pcie-switch-downstream-ports attached to the
pcie-switch-upstream-port).
This is a standard PCI root bus (not a bridge) that can be added to a
440fx-based domain. Although it uses a PCI slot, this is *not* how it
is connected into the PCI bus hierarchy, but is only used for
control. Each pci-expander-bus provides 32 slots (0-31) that can
accept hotplug of standard PCI devices.
The usefulness of pci-expander-bus relative to a pci-bridge is that
the NUMA node of the bus can be specified with the <node> subelement
of <target>. This gives guest-side visibility to the NUMA node of
attached devices (presuming that management apps only assign a device
to a bus that has a NUMA node number matching the node number of the
device on the host).
Each pci-expander-bus also has a "busNr" attribute. The expander-bus
itself will take the busNr specified, and all buses that are connected
to this bus (including the pci-bridge that is automatically added to
any expander bus of model "pxb" (see the next commit)) will use
busNr+1, busNr+2, etc, and the pci-root (or the expander-bus with next
lower busNr) will use bus numbers lower than busNr.
This is especially useful for "bus", since the bus of a device's pci
address is matched to the "index" of a controller to determine which
bus it will be connected to, and "index" is always specified in
decimal - being able to specify both in decimal at least makes it
easier to assure a device is being assigned to the correct bus when it
is added. For the other attributes, it is just a convenience.
(MB: the parser already allows for any of these attributes to be given
in decimal, and there are even examples floating around on the
internet that give them in decimal rather than hex (written in the
days before virsh did schema validation on all XML). This only updates
the schema to match the parser.)
nwfilter.rng defines uint16range and uint32range, but in a different
manner (it also allows a variable name as the value, rather than just
a decimal or hex number). I wanted to add uint16range to
basictypes.rng, but my desired definition was parallel to those for
uint8range and uint24range which are defined in basictypes.rng - they
*don't* allow a variable name for the value.
The simplest path to make everyone happy is to make the "plain"
versions in basictypes.rng have simpler names - "uint8", "uint16", and
"uint24". This patch renames uint8range and uint24range to uint8 and
uint24, while the next patch will add uint16.
The pcie-switch-downstream-port and pcie-root-port controllers have
only a single slot, numbered 0, and the greate majority of all guest
PCI devices are plugged into function 0 of whatever slot they're
using. The parser makes these optional, setting them to 0 when not
specified, and it's logical for the schema to also make them optional.
This cleanups the documentation, reformat some of the paragraphs to use
<p> instead of </br> and rewrites the listen part to be more extendable.
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
According to MDN[1], 'margin-left' and similar CSS properties,
including 'margin-right', cannot be applied to the '::first-line'
pseudo-element, so this rule will never have any effect and can
be safely removed.
[1] https://developer.mozilla.org/en/docs/Web/CSS/::first-line
This patch adds new xml element, and so we can have the option of
also having perf events enabled immediately at startup.
Signed-off-by: Qiaowei Ren <qiaowei.ren@intel.com>
Message-id: 1459171833-26416-6-git-send-email-qiaowei.ren@intel.com
While we have a wiki page describing the feature [1] since the
feature is distributed in our .tar.gz we ought to document it. So
I went ahead, copied the wiki page and reformatted so it fits our
docs coding style.
1: http://wiki.libvirt.org/page/NSS_module
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
- remove top padding for h1. this means page titles sit flush with the top
of the side bar (like 'The virtualization API' on the front page)
- up the top padding for the remaining sections. makes it visually easier
to tell adjacent header sections apart, especially in dense wiki pages
- use two different spacing levels for h2-h4 and h5-h6,
gives pages some more visual flexibility
- use a slightly lower bottom padding... this makes top padding stick out
more which makes it visually easier to differentiate between adjacent
header sections
In order to follow recent comments which indicate support for specific
feature bits are supported by a specific QEMU version add the version
from whence the relaxed, vapic, and spinlocks support was added.
This patch adds support for "vpindex", "runtime", "synic",
"stimer", and "vendor_id" features available in qemu 2.5+.
- When Hyper-V "vpindex" is on, guest can use MSR HV_X64_MSR_VP_INDEX
to get virtual processor ID.
- Hyper-V "runtime" enlightement feature allows to use MSR
HV_X64_MSR_VP_RUNTIME to get the time the virtual processor consumes
running guest code, as well as the time the hypervisor spends running
code on behalf of that guest.
- Hyper-V "synic" stands for Synthetic Interrupt Controller, which is
lapic extension controlled via MSRs.
- Hyper-V "stimer" switches on Hyper-V SynIC timers MSR's support.
Guest can setup and use fired by host events (SynIC interrupt and
appropriate timer expiration message) as guest clock events
- Hyper-V "reset" allows guest to reset VM.
- Hyper-V "vendor_id" exposes hypervisor vendor id to guest.
Signed-off-by: Nikolay Shirokovskiy <nshirokovskiy@virtuozzo.com>
Signed-off-by: John Ferlan <jferlan@redhat.com>
When reading in an XML definition for a SCSI target device, the name
property of struct scsi_target refers to the @target element.
Let's fix this obvious typo and also extend the XML schema to provide
validation.
Signed-off-by: Bjoern Walk <bwalk@linux.vnet.ibm.com>
Most hypervisors use Hardware Assisted Paging by default and don't
require specifying the feature in domain conf. But some hypervisors
support disabling HAP on a per-domain basis. To enable HAP by default
yet provide a knob to disable it, extend the <hap> feature with a
'state=on|off' attribute, similar to <pvspinlock> and <vmport> features.
In the absence of <hap>, the hypervisor default (on) is used. <hap>
without the state attribute would be the same as <hap state='on'/> for
backwards compatibility. And of course <hap state='off'/> disables hap.
Signed-off-by: Jim Fehlig <jfehlig@suse.com>
If we expose this information, which is one byte in every PCI config
file, we let all mgmt apps know whether the device itself is an endpoint
or not so it's easier for them to decide whether such device can be
passed through into a VM (endpoint) or not (*-bridge).
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1317531
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
The docs claims the cache attribute of the disk <driver>
element supports 'default' as one of its permissible values,
but such configuration fails virt-xml-validate. Add 'default'
as one of the cache attribute choices in domaincommon.rng.
- Add line-height:150% spacing for all text. This makes text lines far
less cramped, and seems closer visually to what wikipedia uses.
- Remove bottom and top margin from lists: entries seemed needlessly
spread out.
- Reduce sublist indentation a bit
- Add a bottom border after headings: IMO this greatly helps in break
up the vertical flow of a big page of text. Doesn't look great on the
front page, but helps a lot on dense pages like formatdomain
- change font-family to just 'sans-serif' rather than hardcode a few
font families. this means we abide the user's browser font setting,
and makes us consistent with other sites like en.wikipedia.org
- raise font-size to 90%. this is what en.wikipedia.org uses.
With these two tweaks, libvirt.org text renders the same as
en.wikipedia.org with fedora firefox out of the box config. Previously
the font on libvirt.org was very small and difficult to read.
Extend the chardev source XML so that there is a new optional
<log/> element, which is applicable to all character device
backend types. For example, to log output of a TCP backed
serial port
<serial type='tcp'>
<source mode='connect' host='127.0.0.1' service='9999'/>
<protocol type='raw'/>
<log file='/var/log/libvirt/qemu/demo-serial0.log' append='on'/>
<target port='0'/>
</serial>
Not all hypervisors will support use of logfiles.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>