Rather than assume that NOT FC_HOST is SCSI_HOST, let's call them out
specifically. Makes it easier to find SCSI_HOST code/structs and ensures
something isn't missed in the future
For non-local storage drivers we can't expect to use the "scrub" tool to
wipe the volume. Split the code into a separate backend function so that
we can add protocol specific code later.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1118710
For non-local storage drivers we can't expect to use the FDStream
backend for up/downloading volumes. Split the code into a separate
backend function so that we can add protocol specific code later.
Commit id 'ac9a0963' refactored out the 'withCapacity' for the
virStorageBackendUpdateVolInfo() API. See:
http://www.redhat.com/archives/libvir-list/2014-April/msg00043.html
This resulted in a difference in how 'virsh vol-info --pool <poolName>
<volume>' or 'virsh vol-list vol-list --pool <poolName> --details' outputs
the capacity information for a directory pool with a qcow2 sparse file.
For example, using the following XML
mkdir /home/TestPool
cat testpool.xml
<pool type='dir'>
<name>TestPool</name>
<uuid>6bf80895-10b6-75a6-6059-89fdea2aefb7</uuid>
<source>
</source>
<target>
<path>/home/TestPool</path>
<permissions>
<mode>0755</mode>
<owner>0</owner>
<group>0</group>
</permissions>
</target>
</pool>
virsh pool-create testpool.xml
virsh vol-create-as --pool TestPool temp_vol_1 \
--capacity 1048576 --allocation 1048576 --format qcow2
virsh vol-info --pool TestPool temp_vol_1
Results in listing a Capacity value. Prior to the commit, the value would
be '1.0 MiB' (1048576 bytes). However, after the commit the output would be
(for example) '192.50 KiB', which for my system was the size of the volume
in my file system (eg 'ls -l TestPool/temp_vol_1' results in '197120' bytes
or 192.50 KiB). While perhaps technically correct, it's not necessarily
what the user expected (certainly virt-test didn't expect it).
This patch restores the code to not update the target capacity for this path
More instances of failure to report (unlikely) readdir errors.
In one case, I chose to ignore them, given that a readdir error
would be no different than timing out on the loop, where the
fallback path behaves correctly either way.
* src/storage/storage_backend.c (virStorageBackendStablePath):
Ignore readdir errors.
* src/storage/storage_backend_fs.c
(virStorageBackendFileSystemRefresh): Report readdir errors.
* src/storage/storage_backend_iscsi.c
(virStorageBackendISCSIGetHostNumber): Likewise.
* src/storage/storage_backend_scsi.c (getNewStyleBlockDevice)
(getBlockDevice, virStorageBackendSCSIFindLUs): Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
Currently VolOpen notifies the user of a potentially non-fatal failure by
returning -2 and logging a VIR_WARN or VIR_INFO. Unfortunately most
callers treat -2 as fatal but don't actually report any message with
the error APIs.
Rename the VOL_OPEN_ERROR flag to VOL_OPEN_NOERROR. If NOERROR is specified,
we preserve the current behavior of returning -2 (there's only one caller
that wants this).
However in the default case, only return -1, and actually use the error
APIs. Fix up a couple callers as a result.
Now that each virStorageSource can track allocation information,
and given that we already have the information without extra
syscalls, it's easier to just always populate the information
directly into the struct than it is to sometimes pass the address
of the struct members down the call chain.
* src/storage/storage_backend.h (virStorageBackendUpdateVolInfo)
(virStorageBackendUpdateVolTargetInfo)
(virStorageBackendUpdateVolTargetInfoFD): Update signature.
* src/storage/storage_backend.c (virStorageBackendUpdateVolInfo)
(virStorageBackendUpdateVolTargetInfo)
(virStorageBackendUpdateVolTargetInfoFD): Always populate struct
members instead.
* src/storage/storage_backend_disk.c
(virStorageBackendDiskMakeDataVol): Update client.
* src/storage/storage_backend_fs.c (virStorageBackendProbeTarget)
(virStorageBackendFileSystemRefresh)
(virStorageBackendFileSystemVolRefresh): Likewise.
* src/storage/storage_backend_gluster.c
(virStorageBackendGlusterRefreshVol): Likewise.
* src/storage/storage_backend_logical.c
(virStorageBackendLogicalMakeVol): Likewise.
* src/storage/storage_backend_mpath.c
(virStorageBackendMpathNewVol): Likewise.
* src/storage/storage_backend_scsi.c
(virStorageBackendSCSINewLun): Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
One of the features of qcow2 is that a wrapper file can have
more capacity than its backing file from the guest's perspective;
what's more, sparse files make tracking allocation of both
the active and backing file worthwhile. As such, it makes
more sense to show allocation numbers for each file in a chain,
and not just the top-level file. This sets up the fields for
the tracking, although it does not modify XML to display any
new information.
* src/util/virstoragefile.h (_virStorageSource): Add fields.
* src/conf/storage_conf.h (_virStorageVolDef): Drop redundant
fields.
* src/storage/storage_backend.c (virStorageBackendCreateBlockFrom)
(createRawFile, virStorageBackendCreateQemuImgCmd)
(virStorageBackendCreateQcowCreate): Update clients.
* src/storage/storage_driver.c (storageVolDelete)
(storageVolCreateXML, storageVolCreateXMLFrom, storageVolResize)
(storageVolWipeInternal, storageVolGetInfo): Likewise.
* src/storage/storage_backend_fs.c (virStorageBackendProbeTarget)
(virStorageBackendFileSystemRefresh)
(virStorageBackendFileSystemVolResize)
(virStorageBackendFileSystemVolRefresh): Likewise.
* src/storage/storage_backend_logical.c
(virStorageBackendLogicalMakeVol)
(virStorageBackendLogicalCreateVol): Likewise.
* src/storage/storage_backend_scsi.c
(virStorageBackendSCSINewLun): Likewise.
* src/storage/storage_backend_mpath.c
(virStorageBackendMpathNewVol): Likewise.
* src/storage/storage_backend_rbd.c
(volStorageBackendRBDRefreshVolInfo)
(virStorageBackendRBDCreateImage): Likewise.
* src/storage/storage_backend_disk.c
(virStorageBackendDiskMakeDataVol)
(virStorageBackendDiskCreateVol): Likewise.
* src/storage/storage_backend_sheepdog.c
(virStorageBackendSheepdogBuildVol)
(virStorageBackendSheepdogParseVdiList): Likewise.
* src/storage/storage_backend_gluster.c
(virStorageBackendGlusterRefreshVol): Likewise.
* src/conf/storage_conf.c (virStorageVolDefFormat)
(virStorageVolDefParseXML): Likewise.
* src/test/test_driver.c (testOpenVolumesForPool)
(testStorageVolCreateXML, testStorageVolCreateXMLFrom)
(testStorageVolDelete, testStorageVolGetInfo): Likewise.
* src/esx/esx_storage_backend_iscsi.c (esxStorageVolGetXMLDesc):
Likewise.
* src/esx/esx_storage_backend_vmfs.c (esxStorageVolGetXMLDesc)
(esxStorageVolCreateXML): Likewise.
* src/parallels/parallels_driver.c (parallelsAddHddByVolume):
Likewise.
* src/parallels/parallels_storage.c (parallelsDiskDescParseNode)
(parallelsStorageVolDefineXML, parallelsStorageVolCreateXMLFrom)
(parallelsStorageVolDefRemove, parallelsStorageVolGetInfo):
Likewise.
* src/vbox/vbox_tmpl.c (vboxStorageVolCreateXML)
(vboxStorageVolGetXMLDesc): Likewise.
* tests/storagebackendsheepdogtest.c (test_vdi_list_parser):
Likewise.
* src/phyp/phyp_driver.c (phypStorageVolCreateXML): Likewise.
Any source file which calls the logging APIs now needs
to have a VIR_LOG_INIT("source.name") declaration at
the start of the file. This provides a static variable
of the virLogSource type.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
The "checkPool" is a bit different for pool with "fc_host"
type source adapter, since the vHBA it's based on might be
not created yet (it's created by "startPool", which is
involked after "checkPool" in storageDriverAutostart). So it
should not fail, otherwise the "autostart" of the pool will
fail either.
The problem is easy to reproduce:
* Enable "autostart" for the pool
* Restart libvirtd service
* Check the pool's state
For pool which relies on remote resources, such as a "iscsi" type
pool, since how long it takes to export the corresponding devices
to host's sysfs is really depended, it could depend on the network
connection, it also could depend on the host's udev procedures. So
it's likely that the volumes are not able to be detected during pool
starting process, polling the sysfs doesn't work, since we don't
know how much time is best for the polling, and even worse, the
volumes could still be not detected or partly not detected even after
the polling. So we end up with a documentation to prompt the fact,
in virsh manual.
And as a small improvement, let's explicitly say no LUNs found in
the debug log in that case.
It makes no sense to go forward to get the parent host number of a
HBA, and treat the HBA as a vHBA with trying to delete it.
Signed-off-by: Osier Yang <jyang@redhat.com>
We are calling fstat() at least twice per storage volume in
a directory storage pool; this is rather wasteful. Refactoring
this is also a step towards making code reusable for gluster,
where gluster can provide struct stat but cannot use fstat().
* src/storage/storage_backend.h
(virStorageBackendVolOpenCheckMode)
(virStorageBackendUpdateVolTargetInfoFD): Update signature.
* src/storage/storage_backend.c
(virStorageBackendVolOpenCheckMode): Pass stat results back.
(virStorageBackendUpdateVolTargetInfoFD): Use existing stats.
(virStorageBackendVolOpen, virStorageBackendUpdateVolTargetInfo):
Update callers.
* src/storage/storage_backend_fs.c (virStorageBackendProbeTarget):
Likewise.
* src/storage/storage_backend_scsi.c
(virStorageBackendSCSIUpdateVolTargetInfo): Likewise.
* src/storage/storage_backend_mpath.c
(virStorageBackendMpathUpdateVolTargetInfo): Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
When creating a virtual FC HBA with virsh/libvirt API, an error message
will be returned: "error: Node device not found",
also the 'nodedev-dumpxml' shows wrong information of wwpn & wwnn
for the new created device.
Signed-off-by: xschen@tnsoft.com.cn
This reverts f90af69 which switched wwpn & wwwn in the wrong place.
https://www.kernel.org/doc/Documentation/scsi/scsi_fc_transport.txt
The source code base needs to be adapted as well. Some files
include virutil.h just for the string related functions (here,
the include is substituted to match the new file), some include
virutil.h without any need (here, the include is removed), and
some require both.
This finds the parent for vHBA by iterating over all the HBA
which supports vport_ops capability on the host, and return
the first one which is online, not saturated (vports in use
is less than max_vports).
startPool creates the vHBA if it's not existed yet, stopPool destroys
the vHBA. Also to support autostart, checkPool will creates the vHBA
if it's not existed yet.
The helper iterates over sysfs, to find out the matched scsi host
name by comparing the wwnn,wwpn pair. It will be used by checkPool
and refreshPool of storage scsi backend. New helper getAdapterName
is introduced in storage_backend_scsi.c, which uses the new util
helper virGetFCHostNameByWWN to get the fc_host adapter name.
node device driver names the HBA like "scsi_host5", but storage
driver uses "host5", which could make the user confused. This
changes them to be consistent. However, for back-compat reason,
adapter name like "host5" is still supported.
This introduces 4 new attributes for storage pool source adapter.
E.g.
<adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>
Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
for 'scsi_host' adapter, for back-compat reason. However, mandatory
for 'fc_host' adapter and any new future adapter types. Attribute
'parent' is to specify the parent for the fc_host adapter.
* docs/formatstorage.html.in:
- Add documents for the 4 new attrs
* docs/schemas/storagepool.rng:
- Add RNG schema
* src/conf/storage_conf.c:
- Parse and format the new XMLs
* src/conf/storage_conf.h:
- New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
- New enum virStoragePoolSourceAdapterType
* src/libvirt_private.syms:
- Export TypeToString and TypeFromString
* src/phyp/phyp_driver.c:
- Replace "adapter" with "adapter.data.name", which is member of the union
of the new struct virStoragePoolSourceAdapter now. Later patch will
add the checking, as "adapter.data.name" is only valid for "scsi_host"
adapter.
* src/storage/storage_backend_scsi.c:
- Like above
* tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
- New test for 'fc_host' and "scsi_host" adapter
* tests/storagepoolxml2xmlout/pool-scsi.xml:
- Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
specified now
* tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
- New test
* tests/storagepoolxml2xmltest.c:
- Include the test
virStorageVolLookupByPath is an API call that virt-manager uses
quite a bit when dealing with storage. This call use BackendStablePath
which has several usleep() heuristics that can be tripped up
and hang virt-manager for a while.
Current example: an empty mpath pool pointing to /dev/mapper makes
_any_ calls to virStorageVolLookupByPath take 5 seconds.
The sleep heuristics are actually only needed in certain cases
when we are waiting for new storage to appear, so let's skip the
timeout steps when calling from LookupByPath.
https://www.gnu.org/licenses/gpl-howto.html recommends that
the 'If not, see <url>.' phrase be a separate sentence.
* tests/securityselinuxhelper.c: Remove doubled line.
* tests/securityselinuxtest.c: Likewise.
* globally: s/; If/. If/
Per the FSF address could be changed from time to time, and GNU
recommends the following now: (http://www.gnu.org/licenses/gpl-howto.html)
You should have received a copy of the GNU General Public License
along with Foobar. If not, see <http://www.gnu.org/licenses/>.
This patch removes the explicit FSF address, and uses above instead
(of course, with inserting 'Lesser' before 'General').
Except a bunch of files for security driver, all others are changed
automatically, the copyright for securify files are not complete,
that's why to do it manually:
src/security/security_selinux.h
src/security/security_driver.h
src/security/security_selinux.c
src/security/security_apparmor.h
src/security/security_apparmor.c
src/security/security_driver.c
Update the storage driver to use virReportError instead of
the virStorageReportError custom macro
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Remove a number of pointless checks against PATH_MAX and
add a syntax-check rule to prevent its use in future
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
The SCSI volumes get a better 'key' field based on the fully
qualified volume path. All SCSI volumes have a unique serial
available in hardware which can be obtained by sending a
suitable SCSI command. Call out to udev's 'scsi_id' command
to fetch this value
* src/storage/storage_backend_scsi.c: Improve volume key
field value stability and uniqueness
The SCSI storage backend leaks a string containing the pathname
for each block device it discovers
* src/storage/storage_backend_scsi.c: Free the device name
The SCSI volumes currently get a name like '17:0:0:1' based
on $host:$bus:$target:$lun. The names are intended to be unique
per pool and stable across pool restarts. The inclusion of the
$host component breaks this, because the $host number for iSCSI
pools is dynamically allocated by the kernel at time of login.
This changes the name to be 'unit:0:0:1', ie removes the leading
host component. The 'unit:' prefix is just to ensure the volume
name doesn't start with a number and make it clearer when seen
out of context.
* src/storage/storage_backend_scsi.c: Improve volume name
field value stability and uniqueness
When libvirt starts up all storage pools default to the inactive
state, even if the underlying storage is already active on the
host. This introduces a new API into the internal storage backend
drivers that checks whether a storage pool is already active. If
the pool is active at libvirtd startup, the volume list will be
immediately populated.
* src/storage/storage_backend.h: New internal API for checking
storage pool state
* src/storage/storage_driver.c: Check whether a pool is active
upon driver startup
* src/storage/storage_backend_fs.c, src/storage/storage_backend_iscsi.c,
src/storage/storage_backend_logical.c, src/storage/storage_backend_mpath.c,
src/storage/storage_backend_scsi.c: Add checks for pool state
Similarly to deprecating close(), I am now deprecating fclose() and
introduce VIR_FORCE_FCLOSE() and VIR_FCLOSE(). Also, fdopen() is replaced with
VIR_FDOPEN().
Most of the files are opened in read-only mode, so usage of
VIR_FORCE_CLOSE() seemed appropriate. Others that are opened in write
mode already had the fclose()< 0 check and I converted those to
VIR_FCLOSE()< 0.
I did not find occurrences of possible double-closed files on the way.
Using automated replacement with sed and editing I have now replaced all
occurrences of close() with VIR_(FORCE_)CLOSE() except for one, of
course. Some replacements were straight forward, others I needed to pay
attention. I hope I payed attention in all the right places... Please
have a look. This should have at least solved one more double-close
error.
If a directory pool contains pipes or sockets, a pool start can fail or hang:
https://bugzilla.redhat.com/show_bug.cgi?id=589577
We already try to avoid these special files, but only attempt after
opening the path, which is where the problems lie. Unify volume opening
into helper functions, which use the proper open() flags to avoid error,
followed by fstat to validate storage mode.
Previously, virStorageBackendUpdateVolTargetInfoFD attempted to enforce the
storage mode check, but allowed callers to detect this case and silently
continue. In practice, only the FS backend was using this feature, the rest
were treating unknown mode as an error condition. Unfortunately the InfoFD
function wasn't raising an error message here, so error reporting was
busted.
This patch adds 2 functions: virStorageBackendVolOpen, and
virStorageBackendVolOpenModeSkip. The latter retains the original opt out
semantics, the former now throws an explicit error.
This patch maintains the previous volume mode checks: allowing specific
modes for specific pool types requires a bit of surgery, since VolOpen
is called through several different helper functions.
v2: Use ATTRIBUTE_NONNULL. Drop stat check, just open with
O_NONBLOCK|O_NOCTTY.
v3: Move mode check logic back to VolOpen. Use 2 VolOpen functions with
different error semantics.
v4: Make second VolOpen function more extensible. Didn't opt to change
FS backend defaults, this can just be to fix the original bug.
v5: Prefix default flags with VIR_, use ATTRIBUTE_RETURN_CHECK
Volume detection in the scsi backend was duplicating code already
present in storage_backend.c. Let's drop the duplicate code.
Also, change the shared function name to be less generic, and remove
some error squashing in the other call site.
The virConnectPtr is no longer required for error reporting since
that is recorded in a thread local. Remove use of virConnectPtr
from all APIs in storage_conf.{h,c} and storage_encryption_conf.{h,c}
and update all callers to match