Adds a "ram" attribute globally to the video.model element, that changes
the resulting qemu command line only if video.type == "qxl".
<video>
<model type='qxl' ram='65536' vram='65536' heads='1'/>
</video>
That attribute gets a default value of 64*1024. The schema is unchanged
for other video element types.
The resulting qemu command line change is the addition of
-global qxl-vga.ram_size=<ram>*1024
or
-global qxl.ram_size=<ram>*1024
For the main and secondary qxl devices respectively.
The default for the qxl ram bar is 64*1024 kilobytes (the same as the
default qxl vram bar size).
Add an optional 'type' attribute to <target> element of serial port
device. There are two choices for its value, 'isa-serial' and
'usb-serial'. For backward compatibility, when attribute 'type' is
missing the 'isa-serial' will be chosen as before.
Libvirt XML sample
<serial type='pty'>
<target type='usb-serial' port='0'/>
<address type='usb' bus='0' port='1'/>
</serial>
qemu commandline:
qemu ${other_vm_args} \
-chardev pty,id=charserial0 \
-device usb-serial,chardev=charserial0,id=serial0,bus=usb.0,port=1
The SCLP console is the native console type for s390 and is preferred
over the virtio console as it doesn't require special drivers and
is more efficient. Recent versions of QEMU come with SCLP support
which is hereby enabled.
The new target types 'sclp' and 'sclplm' can be used to specify a
SCLP console. Adding documentation, domain schema and XML processing
support.
Signed-off-by: J.B. Joret <jb@linux.vnet.ibm.com>
Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
This introduces new XML tag "sgio" for disk, its valid values
are "filtered" and "unfiltered", setting it as "filtered" will
set the disk's unpriv_sgio to 0, and "unfiltered" to set it
as 1, which allows the unprivileged SG_IO commands.
The <hostdev> device type has long had a redundant "mode"
attribute, which has always been "subsys". This finally
introduces a new mode "capabilities", which will be used
by the LXC driver for device assignment. Since container
based virtualization uses a single kernel, the idea of
assigning physical PCI devices doesn't make sense. It is
still reasonable to assign USB devices, but for assigning
arbitrary nodes in /dev, the new 'capabilities' mode is
to be used.
The first capability support is 'storage', which is for
assignment of block devices. Functionally this is really
pretty similar to the <disk> support. The only difference
is the device node name is identical in both host and
container namespaces.
<hostdev mode='capabilities' type='storage'>
<source>
<block>/dev/sdf1</block>
</source>
</hostdev>
The second capability support is 'misc', which is for
assignment of character devices. There is no existing
parallel to this. Again the device node is the same
inside & outside the container.
<hostdev mode='capabilities' type='misc'>
<source>
<char>/dev/input/event3</char>
</source>
</hostdev>
The reason for keeping the char & storage devices
separate in the domain XML, is to mirror the split
in the node device XML. NB the node device XML does
not yet report character devices, but that's another
new patch to come
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
If there are multiple video devices
primary = 'yes' marks this video device as the primary one.
The rest are secondary video devices. No more than one could be
mark as primary. If none of them has primary attribute, the first
one will be the primary by default like what it was.
The reason of this changing is that for qemu, only one primary video
device is permitted which can be of any type. For secondary video
devices, only qxl is allowd. Primary attribute removes the restriction
that the first have to be the primary one.
We always put the primary video device into the first position of
video device structure array after parsing.
This is however supported only on domain interfaces with
type='network'. Moreover, target network needs to have at least
inbound QoS set. This is required by hierarchical traffic shaping.
From now on, the required attribute for <inbound/> is either 'average'
(old) or 'floor' (new). This new attribute can be used just for
interfaces type of network (<interface type='network'/>) currently.
QEMU supports setting vendor and product strings for disk since
1.2.0 (only scsi-disk, scsi-hd, scsi-cd support it), this patch
exposes it with new XML elements <vendor> and <product> of disk
device.
This patch introduces the RNG schema and updates necessary data strucutures
to allow various hypervisors to make use of Gluster protocol as one of the
supported network disk backend. Next patch will add support to make use of
this feature in Qemu since it now supports Gluster protocol as one of the
network based storage backend.
Two new optional attributes for <host> element are introduced - 'transport'
and 'socket'. Valid transport values are tcp, unix or rdma. If none specified,
tcp is assumed. If transport is unix, socket specifies path to unix socket.
This patch allows users to specify disks on gluster backends like this:
<disk type='network' device='disk'>
<driver name='qemu' type='raw'/>
<source protocol='gluster' name='Volume1/image'>
<host name='example.org' port='6000' transport='tcp'/>
</source>
<target dev='vda' bus='virtio'/>
</disk>
<disk type='network' device='disk'>
<driver name='qemu' type='raw'/>
<source protocol='gluster' name='Volume2/image'>
<host transport='unix' socket='/path/to/sock'/>
</source>
<target dev='vdb' bus='virtio'/>
</disk>
Signed-off-by: Harsh Prateek Bora <harsh@linux.vnet.ibm.com>
Hypervisors are starting to support HyperV Enlightenment features that
improve behavior of guests running Microsoft Windows operating systems.
This patch adds support for the "relaxed" feature that improves timer
behavior and also establishes a framework to add these features in
future.
Given Daniel's announcement[1], code targetting the next release will
be in 1.0.0, not 0.10.3. Changed mechanically with:
for f in $(git grep -l '0\(.\)10\13\b') ; do
sed -i -e 's/0\(.\)10\13/1\10\10/g' $f
done
[1]https://www.redhat.com/archives/libvir-list/2012-October/msg00403.html
* docs/formatdomain.html.in: Use 1.0.0 for next release.
* src/interface/interface_backend_udev.c: Likewise.
These 3 elements conflicts with each other in either the doc
or the underlying codes.
Current problems:
Problem 1:
The doc shouldn't simply say "These settings are superseded
by CPU tuning. " for element <vcpu>. As except the tuning, <vcpu>
allows to specify the current, maxmum vcpu number. Apart from that,
<vcpu> also allows to specify the placement as "auto", which binds
the domain process to the advisory nodeset from numad.
Problem 2:
Doc for <vcpu> says its "cpuset" specify the physical CPUs
that the vcpus can be pinned. But it's not the truth, as
actually it only pin domain process to the specified physical
CPUs. So either it's a document bug, or code bug.
Problem 3:
Doc for <vcpupin> says it supersed "cpuset" of <vcpu>, it's
not quite correct, as each <vcpupin> specify the pinning policy
only for one vcpu. How about the ones which doesn't have
<vcpupin> specified? it says the vcpu will be pinned to all
available physical CPUs, but what's the meaning of attribute
"cpuset" of <vcpu> then?
Problem 4:
Doc for <emulatorpin> says it pin the emulator threads (domain
process in other context, perhaps another follow up patch to
cleanup the inconsistency is needed) to the physical CPUs
specified its attribute "cpuset". Which conflicts with
<vcpu>'s "cpuset". And actually in the underlying codes,
it set the affinity for domain process twice if both
"cpuset" for <vcpu> and <emulatorpin> are specified,
and <emulatorpin>'s pinning will override <vcpu>'s.
Problem 5:
When "placement" of <vcpu> is "auto" (I.e. uses numad to
get the advisory nodeset to which the domain process is
pinned to), it will also be overridden by <emulatorpin>,
This patch is trying to sort out the conflicts or bugs by:
1) Don't say <vcpu> is superseded by <cputune>
2) Keep the semanteme for "cpuset" of <vcpu> (I.e. Still says it
specify the physical CPUs the virtual CPUs). But modifying it
to mention it also set the pinning policy for domain process,
and the CPU placement of domain process specified by "cpuset"
of <vcpu> will be ingored if <emulatorpin> specified, and
similary, the CPU placement of vcpu thread will be ignored
if it has <vcpupin> specified, for vcpu which doesn't have
<vcpupin> specified, it inherits "cpuset" of <vcpu>.
3) Don't say <vcpu> is supersed by <vcpupin>. If neither <vcpupin>
nor "cpuset" of <vcpu> is specified, the vcpu will be pinned
to all available pCPUs.
4) If neither <emulatorpin> nor "cpuset" of <vcpu> is specified,
the domain process (emulator threads in the context) will be
pinned to all available pCPUs.
5) If "placement" of <vcpu> is "auto", <emulatorpin> is not allowed.
6) hotplugged vcpus will also inherit "cpuset" of <vcpu>
Codes changes according to above document changes:
1) Inherit def->cpumask for each vcpu which doesn't have <vcpupin>
specified, during parsing.
2) ping the vcpu which doesn't have <vcpupin> specified to def->cpumask
either by cgroup for sched_setaffinity(2), which is actually done
by 1).
3) Error out if "placement" == "auto", and <emulatorpin> is specified.
Otherwise, <emulatorpin> is honored, and "cpuset" of <cpuset> is
ignored.
4) Setup cgroup for each hotplugged vcpu, and setup the pinning policy
by either cgroup or sched_setaffinity(2).
5) Remove cgroup and <vcpupin> for each hot unplugged vcpu.
Patches are following (6 in total except this patch)
USB devices can disappear without OS being mad about it, which makes
them ideal for startupPolicy. With this attribute, USB devices can be
configured to be mandatory (the default), requisite (will disappear
during migration if they cannot be found), or completely optional.
While current on_{poweroff,reboot,crash} action configuration is about
configuring life cycle actions, they can all be considered events and
actions that need to be done on a particular event. Let's generalize the
code by renaming life cycle actions to event actions so that it can be
reused later for non-lifecycle events.
This allows the user to control labelling of each character device
separately (the default is to inherit from the VM).
Signed-off-by: Richard W.M. Jones <rjones@redhat.com>
Noticed this by reading the page. It would be so much nicer if our
tools could automatically flag things like this as part of 'make'.
* docs/formatdomain.html.in: Remove extra '>'.
Sometimes when guest machine crashes, coredump can get huge due to the
guest memory. This can be limited using madvise(2) system call and is
being used in QEMU hypervisor. This patch adds an option for configuring
that in the domain XML and related documentation.
Whenever the guest machine fails to boot, new parameter (reboot-timeout)
controls whether it should reboot and after how many ms it should do so.
Docs included.
The introduction of APIC EOI patches had a few little details that
could look better, so this patch fixes that and one more place in the
file as well (same problem).
New options is added to support EOI (End of Interrupt) exposure for
guests. As it makes sense only when APIC is enabled, I added this into
the <apic> element in <features> because this should be tri-state
option (cannot be handled as standalone feature).
After discussion with DB we decided to rename the new iolimit
element as it creates the impression it would be there to
limit (i.e. throttle) I/O instead of specifying immutable
characteristics of a block device.
This is also backed by the fact that the term I/O Limits has
vanished from newer storage admin documentation.
Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
There is a new <pm/> element implemented that can control what ACPI
sleeping states will be advertised by BIOS and allowed to be switched
to by libvirt. The default keeps defaults on hypervisor, otherwise
forces chosen setting.
The documentation of the pm element is added as well.
Introducing a new iolimits element allowing to override certain
properties of a guest block device like the physical and logical
block size.
This can be useful for platforms with 'non-standard' disk formats
like S390 DASD with its 4K block size.
Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
This patch introduces support of setting emulator's period and
quota to limit cpu bandwidth when the vm starts. Also updates
XML Schema for new entries and docs.
This patch adds a new xml element <emulatorpin>, which is a sibling
to the existing <vcpupin> element under the <cputune>, to pin emulator
threads to specified physical CPUs.
Signed-off-by: Tang Chen <tangchen@cn.fujitsu.com>
Signed-off-by: Hu Tao <hutao@cn.fujitsu.com>
A hypervisor may allow to override the disk geometry of drives.
Qemu, as an example with cyls=,heads=,secs=[,trans=].
This patch extends the domain config to allow the specification of
disk geometry with libvirt.
Signed-off-by: J.B. Joret <jb@linux.vnet.ibm.com>
Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
This patch updates the domain and capability XML parser and formatter to
support more than one "seclabel" element for each domain and device. The
RNG schema and the tests related to this are also updated by this patch.
Signed-off-by: Marcelo Cerri <mhcerri@linux.vnet.ibm.com>
The following config elements now support a <vlan> subelements:
within a domain: <interface>, and the <actual> subelement of <interface>
within a network: the toplevel, as well as any <portgroup>
Each vlan element must have one or more <tag id='n'/> subelements. If
there is more than one tag, it is assumed that vlan trunking is being
requested. If trunking is required with only a single tag, the
attribute "trunk='yes'" should be added to the toplevel <vlan>
element.
Some examples:
<interface type='hostdev'/>
<vlan>
<tag id='42'/>
</vlan>
<mac address='52:54:00:12:34:56'/>
...
</interface>
<network>
<name>vlan-net</name>
<vlan trunk='yes'>
<tag id='30'/>
</vlan>
<virtualport type='openvswitch'/>
</network>
<interface type='network'/>
<source network='vlan-net'/>
...
</interface>
<network>
<name>trunk-vlan</name>
<vlan>
<tag id='42'/>
<tag id='43'/>
</vlan>
...
</network>
<network>
<name>multi</name>
...
<portgroup name='production'/>
<vlan>
<tag id='42'/>
</vlan>
</portgroup>
<portgroup name='test'/>
<vlan>
<tag id='666'/>
</vlan>
</portgroup>
</network>
<interface type='network'/>
<source network='multi' portgroup='test'/>
...
</interface>
IMPORTANT NOTE: As of this patch there is no backend support for the
vlan element for *any* network device type. When support is added in
later patches, it will only be for those select network types that
support setting up a vlan on the host side, without the guest's
involvement. (For example, it will be possible to configure a vlan for
a guest connected to an openvswitch bridge, but it won't be possible
to do that for one that is connected to a standard Linux host bridge.)
Following commit added suport the CPU quota/period to the LXC driver.
Update the documentation to reflect that.
commit d9724a81b3
Author: Daniel P. Berrange <berrange@redhat.com>
Date: Thu Nov 10 12:16:26 2011 +0000
Add support for CPU quota/period to LXC driver
Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.vnet.ibm.com>
One of the original ideas behind allowing a <virtualport> in an
interface definition as well as in the <network> definition *and*one
or more <portgroup>s within the network, was that guest-specific
parameteres (like instanceid and interfaceid) could be given in the
interface's virtualport, and more general things (portid, managerid,
etc) could be given in the network and/or portgroup, with all the bits
brought together at guest startup time and combined into a single
virtualport to be used by the guest. This was somehow overlooked in
the implementation, though - it simply picks the "most specific"
virtualport, and uses the entire thing, with no attempt to merge in
details from the others.
This patch uses virNetDevVPortProfileMerge3() to combine the three
possible virtualports into one, then uses
virNetDevVPortProfileCheck*() to verify that the resulting virtualport
type is appropriate for the type of network, and that all the required
attributes for that type are present.
An example of usage is this: assuming a <network> definitions on host
ABC of:
<network>
<name>testA</name>
...
<virtualport type='openvswitch'/>
...
<portgroup name='engineering'>
<virtualport>
<parameters profileid='eng'/>
</virtualport>
</portgroup>
<portgroup name='sales'>
<virtualport>
<parameters profileid='sales'/>
</virtualport>
</portgroup>
</network>
and the same <network> on host DEF of:
<network>
<name>testA</name>
...
<virtualport type='802.1Qbg'>
<parameters typeid="1193047" typeidversion="2"/>
</virtualport>
...
<portgroup name='engineering'>
<virtualport>
<parameters managerid="11"/>
</virtualport>
</portgroup>
<portgroup name='sales'>
<virtualport>
<parameters managerid="55"/>
</virtualport>
</portgroup>
</network>
and a guest <interface> definition of:
<interface type='network'>
<source network='testA' portgroup='sales'/>
<virtualport>
<parameters instanceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"
interfaceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"\>
</virtualport>
...
</interface>
If the guest was started on host ABC, the <virtualport> used would be:
<virtualport type='openvswitch'>
<parameters interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'
profileid='sales'/>
</virtualport>
but if that guest was started on host DEF, the <virtualport> would be:
<virtualport type='802.1Qbg'>
<parameters instanceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"
typeid="1193047" typeidversion="2"
managerid="55"/>
</virtualport>
Additionally, if none of the involved <virtualport>s had a specified type
(this includes cases where no virtualport is given at all),
With 0.10.0-rc0 out the door, we are committed to the next version
number.
* src/libvirt_public.syms (LIBVIRT_0.9.14): Rename...
(LIBVIRT_0.10.0): ...to this.
* docs/formatdomain.html.in: Fix fallout.
* src/openvz/openvz_driver.c (openvzDriver): Likewise.
* src/remote/remote_driver.c (remote_driver): Likewise.
Libvirt adds a USB controller to the guest even if the user does not
specify any in the XML. This is due to back-compat reasons.
To allow disabling USB for a guest this patch adds a new USB controller
type "none" that disables USB support for the guest.