The virDBusMethodCall method has a DBusError as one of its
parameters. If the caller wants to pass a non-NULL value
for this, it immediately makes the calling code require
DBus at build time. This has led to breakage of non-DBus
builds several times. It is desirable that only the virdbus.c
file should need WITH_DBUS conditionals, so we must ideally
remove the DBusError parameter from the method.
We can't simply raise a libvirt error, since the whole point
of this parameter is to give the callers a way to check if
the error is one they want to ignore, without having the logs
polluted with an error message. So, we add a virErrorPtr
parameter which the caller can then either ignore or raise
using the new virReportErrorObject method.
This new method is distinct from virSetError in that it
ensures the logging hooks are run.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Commit 4897698 fixed the build without dbus by only building
the virSystemdPMSupportTarget with SYSTEMD_DAEMON.
Introduce a virDBusMessageUnref wrapper for dbus_message_unref
to let virsystemd.c build without dbus, while still allowing
virsystemdtest to run without SYSTEM_DAEMON.
The caller may not want all DBus error conditions to be turned
into libvirt errors, so provide a way for the caller to get
back the full DBusError object. They can then check the errors
and only report those that they consider to be fatal.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
The test suites often have to create DBus method reply messages
with payloads. Create two helpers for simplifying the process
of creating replies with payloads.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Split the virDBusMethodCall method into a couple of new methods
virDBusCall, virDBusCreateMethod and virDBusCreateMethodV.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
If systemd is installed, but is not the init system,
systemd-machined fails with an unhelpful error message:
Launch helper exited with unknown return code 1
Currently we only check if the "machine1" service is
available (in ListActivatableNames).
Also check if "systemd1" service is registered with DBus
(ListNames).
This fixes https://bugs.gentoo.org/show_bug.cgi?id=493246#c22
The dbus_bus_get() function returns a shared bus connection that
all libraries in a process can use. You are forbidden from calling
close on this connection though, since you can never know if any
other code might be using it.
Add an option to use private dbus bus connections, if the app
wants to be able to close the connection.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
This patch introduces virDBusIsServiceEnabled, we can use
this method to get if the service is supported.
In one case, if org.freedesktop.machine1 is unavailable on
host, we should skip creating machine through systemd.
Signed-off-by: Gao feng <gaofeng@cn.fujitsu.com>
Some systems may not use DBus in their system. Add a method to check if
the system bus is available that doesn't print error messages so that
code can later check for this condition and use an alternative approach.
Depending on the set of mingw packages installed, it is possible
that other .c files hit the mingw header pollution from the
virdbus.h file.
In file included from ../../src/rpc/virnetserver.c:39:0:
../../src/util/virdbus.h:41:35: error: expected ';', ',' or ')' before 'struct'
const char *interface,
^
* src/util/virdbus.h (virDBusCallMethod): Match .c file change.
Signed-off-by: Eric Blake <eblake@redhat.com>
Doing DBus method calls using libdbus.so is tedious in the
extreme. systemd developers came up with a nice high level
API for DBus method calls (sd_bus_call_method). While
systemd doesn't use libdbus.so, their API design can easily
be ported to libdbus.so.
This patch thus introduces methods virDBusCallMethod &
virDBusMessageRead, which are based on the code used for
sd_bus_call_method and sd_bus_message_read. This code in
systemd is under the LGPLv2+, so we're license compatible.
This code is probably pretty unintelligible unless you are
familiar with the DBus type system. So I added some API
docs trying to explain how to use them, as well as test
cases to validate that I didn't screw up the adaptation
from the original systemd code.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
On Fedora 18, when cross-compiling to mingw with the mingw*-dbus
packages installed, compilation fails with:
CC libvirt_net_rpc_server_la-virnetserver.lo
In file included from /usr/i686-w64-mingw32/sys-root/mingw/include/dbus-1.0/dbus/dbus-connection.h:32:0,
from /usr/i686-w64-mingw32/sys-root/mingw/include/dbus-1.0/dbus/dbus-bus.h:30,
from /usr/i686-w64-mingw32/sys-root/mingw/include/dbus-1.0/dbus/dbus.h:31,
from ../../src/util/virdbus.h:26,
from ../../src/rpc/virnetserver.c:39:
/usr/i686-w64-mingw32/sys-root/mingw/include/dbus-1.0/dbus/dbus-message.h:74:58: error: expected ';', ',' or ')' before 'struct'
I have reported this as a bug against two packages:
- mingw-headers, for polluting the namespace
https://bugzilla.redhat.com/show_bug.cgi?id=980270
- dbus, for not dealing with the pollution
https://bugzilla.redhat.com/show_bug.cgi?id=980278
At least dbus has agreed that a future version of dbus headers will
do s/interface/iface/, regardless of what happens in mingw. But it
is also easy to workaround in libvirt in the meantime, without having
to wait for either mingw or dbus to upgrade.
* src/util/virdbus.h (includes): Undo mingw's pollution so that
dbus doesn't fail.
Signed-off-by: Eric Blake <eblake@redhat.com>
https://www.gnu.org/licenses/gpl-howto.html recommends that
the 'If not, see <url>.' phrase be a separate sentence.
* tests/securityselinuxhelper.c: Remove doubled line.
* tests/securityselinuxtest.c: Likewise.
* globally: s/; If/. If/
Per the FSF address could be changed from time to time, and GNU
recommends the following now: (http://www.gnu.org/licenses/gpl-howto.html)
You should have received a copy of the GNU General Public License
along with Foobar. If not, see <http://www.gnu.org/licenses/>.
This patch removes the explicit FSF address, and uses above instead
(of course, with inserting 'Lesser' before 'General').
Except a bunch of files for security driver, all others are changed
automatically, the copyright for securify files are not complete,
that's why to do it manually:
src/security/security_selinux.h
src/security/security_driver.h
src/security/security_selinux.c
src/security/security_apparmor.h
src/security/security_apparmor.c
src/security/security_driver.c
DBus connection. The HAL device code further requires that
the DBus connection is integrated with the event loop and
provides such glue logic itself.
The forthcoming FirewallD integration also requires a
dbus connection with event loop integration. Thus we need
to pull the current event loop glue out of the HAL driver.
Thus we create src/util/virdbus.{c,h} files. This contains
just one method virDBusGetSystemBus() which obtains a handle
to the single shared system bus instance, with event glue
automagically setup.