Commit Graph

518 Commits

Author SHA1 Message Date
Fred A. Kemp
feba2febce qemu: Support setting the 'removable' flag for USB disks
Add an attribute named 'removable' to the 'target' element of disks,
which controls the removable flag. For instance, on a Linux guest it
controls the value of /sys/block/$dev/removable. This option is only
valid for USB disks (i.e. bus='usb'), and its default value is 'off',
which is the same behaviour as before.

To achieve this, 'removable=on' (or 'off') is appended to the '-device
usb-storage' parameter sent to qemu when adding a USB disk via
'-disk'. A capability flag QEMU_CAPS_USB_STORAGE_REMOVABLE was added
to keep track if this option is supported by the qemu version used.

Bug: https://bugzilla.redhat.com/show_bug.cgi?id=922495
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
2013-09-02 14:45:38 +02:00
Ján Tomko
01cda91809 Add pcihole64 element to root PCI controllers
<controller type='pci' index='0' model='pci-root'>
  <pcihole64 unit='KiB'>1048576</pcihole64>
</controller>

It can be used to adjust (or disable) the size of the 64-bit
PCI hole. The size attribute is in kilobytes (different unit
can be specified on input), but it gets rounded up to
the nearest GB by QEMU.

Disabling it will be needed for guests that crash with the
64-bit PCI hole (like Windows XP), see:
https://bugzilla.redhat.com/show_bug.cgi?id=990418
2013-08-27 17:42:29 +02:00
Aline Manera
796513d7cc Add ftp protocol support for cdrom disk
The ftp protocol is already recognized by qemu/KVM so add this support to
libvirt as well.
The xml should be as following:

     <disk type='network' device='cdrom'>
       <source protocol='ftp' name='/url/path'>
         <host name='host.name' port='21'/>
       </source>
     </disk>

Signed-off-by: Aline Manera <alinefm@br.ibm.com>
2013-08-27 14:50:24 +02:00
Aline Manera
3485ce4e9d Add http protocol support for cdrom disk
QEMU/KVM already allows a HTTP URL for the cdrom ISO image so add this support
to libvirt as well.
The xml should be as following:

    <disk type='network' device='cdrom'>
      <source protocol='http' name='/url/path'>
        <host name='host.name' port='80'/>
      </source>
    </disk>

Signed-off-by: Aline Manera <alinefm@br.ibm.com>
2013-08-27 14:50:24 +02:00
Jiri Denemark
8a38db0dd9 schema: Allow dots in device aliases
Commit 01b88127 changed aliases for PCI controller devices to "pcie.0" or
"pci.%u". Thus device aliases may now contain dots.
2013-08-26 15:26:49 +02:00
Eric Blake
0f082e699e selinux: distinguish failure to label from request to avoid label
https://bugzilla.redhat.com/show_bug.cgi?id=924153

Commit 904e05a2 (v0.9.9) added a per-<disk> seclabel element with
an attribute relabel='no' in order to try and minimize the
impact of shutdown delays when an NFS server disappears.  The idea
was that if a disk is on NFS and can't be labeled in the first
place, there is no need to attempt the (no-op) relabel on domain
shutdown.  Unfortunately, the way this was implemented was by
modifying the domain XML so that the optimization would survive
libvirtd restart, but in a way that is indistinguishable from an
explicit user setting.  Furthermore, once the setting is turned
on, libvirt avoids attempts at labeling, even for operations like
snapshot or blockcopy where the chain is being extended or pivoted
onto non-NFS, where SELinux labeling is once again possible.  As
a result, it was impossible to do a blockcopy to pivot from an
NFS image file onto a local file.

The solution is to separate the semantics of a chain that must
not be labeled (which the user can set even on persistent domains)
vs. the optimization of not attempting a relabel on cleanup (a
live-only annotation), and using only the user's explicit notation
rather than the optimization as the decision on whether to skip
a label attempt in the first place.  When upgrading an older
libvirtd to a newer, an NFS volume will still attempt the relabel;
but as the avoidance of a relabel was only an optimization, this
shouldn't cause any problems.

In the ideal future, libvirt will eventually have XML describing
EVERY file in the backing chain, with each file having a separate
<seclabel> element.  At that point, libvirt will be able to track
more closely which files need a relabel attempt at shutdown.  But
until we reach that point, the single <seclabel> for the entire
<disk> chain is treated as a hint - when a chain has only one
file, then we know it is accurate; but if the chain has more than
one file, we have to attempt relabel in spite of the attribute,
in case part of the chain is local and SELinux mattered for that
portion of the chain.

* src/conf/domain_conf.h (_virSecurityDeviceLabelDef): Add new
member.
* src/conf/domain_conf.c (virSecurityDeviceLabelDefParseXML):
Parse it, for live images only.
(virSecurityDeviceLabelDefFormat): Output it.
(virDomainDiskDefParseXML, virDomainChrSourceDefParseXML)
(virDomainDiskSourceDefFormat, virDomainChrDefFormat)
(virDomainDiskDefFormat): Pass flags on through.
* src/security/security_selinux.c
(virSecuritySELinuxRestoreSecurityImageLabelInt): Honor labelskip
when possible.
(virSecuritySELinuxSetSecurityFileLabel): Set labelskip, not
norelabel, if labeling fails.
(virSecuritySELinuxSetFileconHelper): Fix indentation.
* docs/formatdomain.html.in (seclabel): Document new xml.
* docs/schemas/domaincommon.rng (devSeclabel): Allow it in RNG.
* tests/qemuxml2argvdata/qemuxml2argv-seclabel-*-labelskip.xml:
* tests/qemuxml2argvdata/qemuxml2argv-seclabel-*-labelskip.args:
* tests/qemuxml2xmloutdata/qemuxml2xmlout-seclabel-*-labelskip.xml:
New test files.
* tests/qemuxml2argvtest.c (mymain): Run the new tests.
* tests/qemuxml2xmltest.c (mymain): Likewise.

Signed-off-by: Eric Blake <eblake@redhat.com>
2013-08-20 10:39:03 -06:00
Guannan Ren
93319da42c conf: add startupPolicy attribute for harddisk
Add startupPolicy attribute for harddisk with type "file",
"block" and "dir". 'requisite' is not supported currently for
harddisk.
2013-08-07 14:31:34 +08:00
Laine Stump
62ac6b4354 qemu: add dmi-to-pci-bridge controller
This PCI controller, named "dmi-to-pci-bridge" in the libvirt config,
and implemented with qemu's "i82801b11-bridge" device, connects to a
PCI Express slot (e.g. one of the slots provided by the pcie-root
controller, aka "pcie.0" on the qemu commandline), and provides 31
*non-hot-pluggable* PCI (*not* PCIe) slots, numbered 1-31.

Any time a machine is defined which has a pcie-root controller
(i.e. any q35-based machinetype), libvirt will automatically add a
dmi-to-pci-bridge controller if one doesn't exist, and also add a
pci-bridge controller. The reasoning here is that any useful domain
will have either an immediate (startup time) or eventual (subsequent
hot-plug) need for a standard PCI slot; since the pcie-root controller
only provides PCIe slots, we need to connect a dmi-to-pci-bridge
controller to it in order to get a non-hot-plug PCI slot that we can
then use to connect a pci-bridge - the slots provided by the
pci-bridge will be both standard PCI and hot-pluggable.

Since pci-bridge devices themselves can not be hot-plugged into a
running system (although you can hot-plug other devices into a
pci-bridge's slots), any new pci-bridge controller that is added can
(and will) be plugged into the dmi-to-pci-bridge as long as it has
empty slots available.

This patch is also changing the qemuxml2xml-pcie test from a "DO_TEST"
to a "DO_DIFFERENT_TEST". This is so that the "before" xml can omit
the automatically added dmi-to-pci-bridge and pci-bridge devices, and
the "after" xml can include it - this way we are testing if libvirt is
properly adding these devices.
2013-08-05 15:40:49 -04:00
Laine Stump
48a3f48ac5 qemu: add pcie-root controller
This controller is implicit on q35 machinetypes. It provides 31 PCIe
(*not* PCI) slots as controller 0.

Currently there are no devices that can connect to pcie-root, and no
implicit pci controller on a q35 machine, so q35 is still
unusable. For a usable q35 system, we need to add a
"dmi-to-pci-bridge" pci controller, which can connect to pcie-root,
and provides standard pci slots that can be used to connect other
devices.
2013-08-05 15:13:56 -04:00
John Ferlan
c00b2f0dd1 conf: Introduce new XML tag "mode" for disk source
There are two ways to use a iSCSI LUN as disk source for qemu.

 * The LUN's path as it shows up on host, e.g.
   /dev/disk/by-path/ip-$ip:3260-iscsi-$iqn-fc18:iscsi.iscsi0-lun-1

 * The libiscsi URI from the storage pool source element host attribute, e.g.
   iscsi://demo.org:6000/iqn.1992-01.com.example/1

For a "volume" type disk, if the specified "pool" is of iscsi
type, we should support to use the LUN in either of above 2 ways.
That's why to introduce a new XML tag "mode" for the disk source
(libvirt should support iscsi pool with libiscsi, but it's another
new feature, which should be done later).

The "mode" can be either of "host" or "direct". Use "host" to indicate
use of the LUN with the path as it shows up on host. Use "direct" to
indicate to use it with the source pool host URI (future patches may support
to use network type libvirt storage too, e.g. Ceph)
2013-07-22 14:01:04 -04:00
John Ferlan
9ed3a5ca34 Add 'period' for Memballoon statistics gathering capability
Add a period in seconds to allow/enable statistics gathering from the
Balloon driver for 'virsh dommemstat <domain>'.
2013-07-16 08:44:52 -04:00
Ján Tomko
2e4dd4107e conf: don't check hyperv spinlock retries if disabled
<hyperv>
  <spinlocks state='off'/>
</hyperv>

results in:
error: XML error: missing HyperV spinlock retry count

Don't require retries when state is off and use virXPathUInt
instead of virXPathString to simplify parsing.

https://bugzilla.redhat.com/show_bug.cgi?id=784836#c19
2013-07-04 18:39:56 +02:00
Gao feng
6c30ea2c35 LXC: Introduce New XML element for user namespace
This patch introduces new element <idmap> for
user namespace. for example
<idmap>
    <uid start='0' target='1000' count='10'/>
    <gid start='0' target='1000' count='10'/>
</idmap>

this new element is used for setting proc files
/proc/<pid>/{uid_map,gid_map}.

This patch also supports multiple uid/gid elements
setting in XML configuration.

We don't support the semi configuation, user has to
configure uid and gid both.

Signed-off-by: Gao feng <gaofeng@cn.fujitsu.com>
2013-07-02 11:20:04 +01:00
Ján Tomko
800b51d7b0 conf: add vapic and spinlocks to hyperv features
Add new CPU features for HyperV:
vapic for virtual APIC support
spinlocks for setting spinlock support

<features>
  <hyperv>
    <vapic state='on'/>
    <spinlocks state='on' retries='4096'/>
  </hyperv>
</features>

https://bugzilla.redhat.com/show_bug.cgi?id=784836
2013-06-21 12:33:46 +02:00
Claudio Bley
12edde5cbb schema: simplify RNG pattern, remove superfluous <optional> 2013-06-12 16:14:44 +02:00
Michal Privoznik
7e744f8199 Introduce /domain/devices/interface/driver/@queues attribute
This attribute is going to represent number of queues for
multique vhost network interface. This commit implements XML
extension part of the feature and add one test as well. For now,
we can only do xml2xml test as qemu command line generation code
is not adapted yet.
2013-05-22 16:31:27 +02:00
Guannan Ren
2a58d07654 conf: add 'sharePolicy' attribute to graphics element for vnc
-vnc :5900,share=allow-exclusive
allows clients to ask for exclusive access which is
implemented by dropping other connections Connecting
multiple clients in parallel requires all clients asking
for a shared session (vncviewer: -shared switch)

 -vnc :5900,share=force-shared
disables exclusive client access.  Useful for shared
desktop sessions, where you don't want someone forgetting
specify -shared disconnect everybody else.

 -vnc :5900,share=ignore
completely ignores the shared flag and allows everybody
connect unconditionally
2013-05-22 19:18:43 +08:00
Osier Yang
9049d6a8c7 qemu: Change values of disk discard
QEMU might support more values for "-drive discard", so using Bi-state
values (on/off) for it doesn't make sense.

"on" maps to "unmap", "off" maps to "ignore":

<...>
@var{discard} is one of "ignore" (or "off") or "unmap" (or "on") and
controls whether @dfn{discard} (also known as @dfn{trim} or @dfn{unmap})
requests are ignored or passed to the filesystem.  Some machine types
may not support discard requests.
</...>
2013-05-17 13:03:25 +08:00
Jiri Denemark
555866389c Add support for locking domain's memory pages
The following XML configuration can be used to request all domain's
memory pages to be kept locked in host's memory (i.e., domain's memory
pages will not be swapped out):

      <memoryBacking>
        <locked/>
      </memoryBacking>
2013-05-16 23:03:08 +02:00
Osier Yang
6765316093 conf: Introduce sgio for hostdev
"sgio" is only valid for scsi host device.
2013-05-17 00:46:44 +08:00
Osier Yang
f2c1d9a804 conf: Introduce <shareable> for hostdev
Unlike disk device, the scsi-generic always writethrough the data,
so no need to introduce a "cache" tag, and set "cache=off".
2013-05-16 23:41:25 +08:00
Osier Yang
a7c4202cdd qemu: Support discard for disk
QEMU introduced "discard" option for drive since commit a9384aff53,

<...>
@var{discard} is one of "ignore" (or "off") or "unmap" (or "on") and
controls whether @dfn{discard} (also known as @dfn{trim} or @dfn{unmap})
requests are ignored or passed to the filesystem.  Some machine types
may not support discard requests.
</...>

This patch exposes the support in libvirt.

QEMU supported "discard" for "-drive" since v1.5.0-rc0:

% git tag --contains a9384aff53
contains
v1.5.0-rc0
v1.5.0-rc1

So this only detects the capability bit using virQEMUCapsProbeQMPCommandLine.
2013-05-15 19:01:00 +08:00
Martin Kletzander
f1ad8d2079 Add VNC WebSocket support
Adding support for new attribute 'websocket' in the '<graphics>'
element, the attribute value is the port to listen on with '-1'
meaning auto-allocation, '0' meaning no websockets.
2013-05-15 09:38:56 +02:00
Osier Yang
77b54b9661 qemu: New XML to disable memory merge at guest startup
QEMU introduced command line "-mem-merge=on|off" (defaults to on) to
enable/disable the memory merge (KSM) at guest startup. This exposes
it by new XML:
  <memoryBacking>
    <nosharepages/>
  </memoryBacking>

The XML tag is same with what we used internally for old RHEL.
2013-05-15 11:25:45 +08:00
Daniel P. Berrange
13579d4544 Add 'nbd' as a valid filesystem driver type
The <filesystem> element can now accept a <driver type='nbd'/>
as an alternative to 'loop'. The benefit of NBD is support
for non-raw disk image formats.

Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2013-05-13 13:15:19 +01:00
Daniel P. Berrange
ada14b86cc Add support for storage format in FS <driver>
Extend the <driver> element in filesystem devices to
allow a storage format to be set. The new attribute
uses 'format' to reflect the storage format. This is
different from the <driver> element in disk devices
which use 'type' to reflect the storage format. This
is because the 'type' attribute on filesystem devices
is already used for the driver backend, for which the
disk devices use the 'name' attribute. Arggggh.

Anyway for disks we have

   <driver name="qemu" type="raw"/>

And for filesystems this change means we now have

   <driver type="loop" format="raw"/>

Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2013-05-13 13:15:19 +01:00
Osier Yang
f4bb7b4807 Introduce <readonly> for hostdev
Since it's generic enough to be used by other types in future, I
put it in <hostdev> as sub-element, though now it's only used by
scsi host device.
2013-05-13 19:02:40 +08:00
Osier Yang
dcd632af72 rng: Interleave hostdev elements 2013-05-13 18:51:16 +08:00
Han Cheng
5c811dcec5 conf: Generic XMLs for scsi hostdev
An example of the scsi hostdev XML:

    <hostdev mode='subsystem' type='scsi'>
      <source>
        <adapter name='scsi_host0'/>
        <address bus='0' target='0' unit='0'/>
      </source>
      <address type='drive' controller='0' bus='0' target='4' unit='8'/>
    </hostdev>

Controller is implicitly added for scsi hostdev, though the scsi
controller's model defaults to "lsilogic", which might be not what
the user wants (same problem exists for virtio-scsi disk). It's
the existing problem, will be addressed later.

The device address must be specified manually. Later patch will let
libvirt generate it automatically.

This only introduces the generic XMLs for scsi hostdev, later patches
will add other elements, e.g. <readonly>, <shareable>.

Signed-off-by: Han Cheng <hanc.fnst@cn.fujitsu.com>
Signed-off-by: Osier Yang <jyang@redhat.com>
2013-05-13 18:23:50 +08:00
Laine Stump
c4f63ef080 conf: formatter/parser/RNG/docs for hostdev <driver name='kvm|vfio'/>
A domain's <interface> or <hostdev>, as well as a <network>'s
<forward>, can now have an optional <driver name='kvm|vfio'/>
element. As of this patch, there is no functionality behind this new
knob - this patch adds support to the domain and network
formatter/parser, and to the RNG and documentation.

When the backend is added, legacy KVM PCI device assignment will
continue to be used when no driver name is specified (or if <driver
name='kvm'/> is specified), but if driver name is 'vfio', the new UEFI
Secure Boot compatible VFIO device assignment will be used.

Note that the parser doesn't automatically insert the current default
value of this setting. This is done on purpose because the two
possibilities are functionally equivalent from the guest's point of
view, and we want to be able to automatically start using vfio as the
default (even for existing domains) at some time in the future. This
is similar to what was done with the "vhost" driver option in
<interface>.
2013-04-25 21:23:38 -04:00
Ján Tomko
df0ebf6b38 conf: add PCI controllers
Add new controller type 'pci' with models 'pci-root' and 'pci-bridge'.
2013-04-25 12:54:38 +02:00
Li Zhang
bf1888738b Add NVRAM device
For pSeries guest in QEMU, NVRAM is one kind of spapr-vio device.
Users are allowed to specify spapr-vio devices'address.
But NVRAM is not supported in libvirt. So this patch is to
add NVRAM device to allow users to specify its address.

In QEMU, NVRAM device's address is specified by
 "-global spapr-nvram.reg=xxxxx".

In libvirt, XML file is defined as the following:

  <nvram>
    <address type='spapr-vio' reg='0x3000'/>
  </nvram>

Signed-off-by: Li Zhang <zhlcindy@linux.vnet.ibm.com>
2013-04-25 16:50:11 +08:00
Osier Yang
45d6c67143 Introduce a sub-element <driver> for controller
Like what we did for "disk", "filesystem" and "interface", this
introduces sub-element <driver> for "controller", and put the "queues"
into it.
2013-04-25 12:10:58 +08:00
Osier Yang
18b428980f Change the tag name "num_queues" into "queues"
Instead of making a choice between the underscore and camelCase, this
simply changes "num_queues" into "queues", which is also consistent
with Michal's multiple queue support for interface.
2013-04-24 23:36:07 +08:00
Laine Stump
0f4f5cb26d rng: tighten up domain <controller> schema
The rng schema for <controller> had been non-specific about which
types of controllers allowed which models, and also allowed the
num_queues attribute (since that hasn't been released yet, should we
rename it to "numQueues"?) and <master> subelement to be included for
any controller type. In reality, half of the models are allowed only
for type='scsi', and the other half only for type='usb', num_queues is
allowed only for type='scsi', and <master> only for type='usb'.

This patch makes a separate <group> for type='scsi' and type='usb',
with each group allowing only the appropriate model values, and
allowing num_queue and <master> only when appropriate.

<interleave> also hadn't been specified, forcing a specific order of
subelements, which should never be done. (Note that the <interleave>
had to surround the main element attributes that are in the <group>
subelements, due to one of the <group>s containing a subelement).
2013-04-18 06:59:27 -04:00
Daniel P. Berrange
8d4adf3efa Add XML config for resource partitions
Allow VMs to be placed into resource groups using the
following syntax

  <resource>
    <partition>/virtualmachines/production</partition>
  </resource>

A resource cgroup will be backed by some hypervisor specific
functionality, such as cgroups with KVM/LXC.

Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2013-04-15 17:35:31 +01:00
Stefan Berger
5eac4f600c Add documentation and schema for TPM passthrough
Supported TPM passthrough XML may look as follows:

    <tpm model='tpm-tis'>
      <backend type='passthrough'>
        <device path='/dev/tpm0'/>
      </backend>
    </tpm>

Signed-off-by: Stefan Berger <stefanb@linux.vnet.ibm.com>
Reviewed-by: Corey Bryant <coreyb@linux.vnet.ibm.com>
Tested-by: Corey Bryant <coreyb@linux.vnet.ibm.com>
2013-04-12 16:55:45 -04:00
Han Cheng
0f5837aac2 schemas: Move PortNumber and sourceinfoadapter to basictypes.rng
The definiton of scsi adapter in storagespool.rng (sourceinfoadapter)
can be used by scsi hostdev in later patch. Move it to basictypes.rng.

PortNumber is defined in both domaincommon.rng and storagespool.rng,
simplify it by moving it to basictypes.rng.

Signed-off-by: Han Cheng <hanc.fnst@cn.fujitsu.com>
2013-04-09 22:34:02 +08:00
Bogdan Purcareata
4aafa1ff86 Update structure & XML definitions to support <hostdev caps=net>
This updates the definitions and supporting structures in the XML
schema and domain configuration files.

Signed-off-by: Bogdan Purcareata <bogdan.purcareata@freescale.com>
2013-04-08 17:40:08 +01:00
Osier Yang
664270b849 Support seclabels for volume type disk
"seclabels" is only valid for 'file' or 'block' type storage volume.
2013-04-08 18:59:50 +08:00
Osier Yang
43404fee37 Support startupPolicy for 'volume' disk
"startupPolicy" is only valid for file type storage volume, otherwise
it fails on starting the domain.
2013-04-08 18:54:37 +08:00
Osier Yang
4bc331c894 Introduce new XMLs to specify disk source using libvirt storage
With this patch, one can specify the disk source using libvirt
storage like:

  <disk type='volume' device='disk'>
    <driver name='qemu' type='raw' cache='none'/>
    <source pool='default' volume='fc18.img'/>
    <target dev='vdb' bus='virtio'/>
  </disk>

"seclabels" and "startupPolicy" are not supported for this new
disk type ("volume"). They will be supported in later patches.

docs/formatdomain.html.in:
  * Add documents for new XMLs
docs/schemas/domaincommon.rng:
  * Add rng for new XMLs;
src/conf/domain_conf.h:
  * New struct for 'volume' type disk source (virDomainDiskSourcePoolDef)
  * Add VIR_DOMAIN_DISK_TYPE_VOLUME for enum virDomainDiskType
src/conf/domain_conf.c:
  * New helper virDomainDiskSourcePoolDefParse to parse the 'volume'
    type disk source.
  * New helper virDomainDiskSourcePoolDefFree to free the source def
    if 'volume' type disk.
tests/qemuxml2argvdata/qemuxml2argv-disk-source-pool.xml:
tests/qemuxml2xmltest.c:
  * New test
2013-04-08 18:48:14 +08:00
Osier Yang
d4bf0a9378 qemu: Support multiple queue virtio-scsi
This introduce a new attribute "num_queues" (same with the good name
QEMU uses) for virtio-scsi controller. An example of the XML:

<controller type='scsi' index='0' model='virtio-scsi' num_queues='8'/>

The corresponding QEMU command line:

-device virtio-scsi-pci,id=scsi0,num_queues=8,bus=pci.0,addr=0x3 \
2013-04-06 10:08:47 +08:00
Daniel P. Berrange
8ef2b2c5b1 Refactor RNG schema for resource tuning
Split the "resource" define out into multiple smaller
defines, one for each type of resource tuning parameter.
This makes the schema a bit clearer to read

Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2013-04-05 10:40:21 +01:00
Osier Yang
ad5298e177 rng: Add definition for network disk source
It's long enough to have a independant definition.
2013-04-03 20:14:05 +08:00
Paolo Bonzini
9f7a9aee37 qemu: add support for LSI MegaRAID SAS1078 (aka megasas) SCSI controller
This does nothing more than adding the new device and capability.
The device is present since QEMU 1.2.0.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2013-03-22 12:11:14 +08:00
Paolo Bonzini
6dca6d84ed domain: parse XML for iscsi authorization credentials
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2013-03-22 12:10:23 +08:00
Paolo Bonzini
8110a8249d domain: make port optional for network disks
Only sheepdog actually required it in the code, and we can use 7000 as the
default---the same value that QEMU uses for the simple "sheepdog:VOLUME"
syntax.  With this change, the schema can be fixed to allow no port.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2013-03-22 12:10:23 +08:00
Martin Kletzander
28933c5574 Correct invalid RNG schemas
The 'trang' utility, which is able to transform '.rng' files into
'.rnc' files, reported some errors in our schemas that weren't caught
by the tools we use in the build.  I haven't added a test for this,
but the validity can be checked by the following command:

trang -I rng -O rnc domain.rng domain.rnc

There were unescaped minuses in regular expressions and we were
constraining int (which is by default in the range of [-2^31;2^31-1]
to maximum of 2^32.  But what we wanted was exactly an unsignedInt.
2013-03-21 17:24:08 +01:00
Paolo Bonzini
1d94891288 domain: add support for iscsi network disks
This plumbs in the XML description of iSCSI shares.  The next patches
will add support for the libiscsi userspace initiator.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2013-03-20 17:30:25 -06:00
Olivia Yin
9545acd9f0 conf: support <dtb> tag in XML domain file 2013-03-19 15:48:58 -06:00
Peter Krempa
32bd699f55 virtio-rng: Add rate limiting options for virtio-RNG
Qemu's implementation of virtio RNG supports rate limiting of the
entropy used. This patch exposes the option to tune this functionality.

This patch is based on qemu commit 904d6f588063fb5ad2b61998acdf1e73fb4

The rate limiting is exported in the XML as:
<devices>
  ...
  <rng model='virtio'>
    <rate bytes='123' period='1234'/>
    <backend model='random'/>
  </rng>
  ...
2013-03-14 13:28:10 +01:00
Viktor Mihajlovski
41ce2c9e94 S390: Documentation for CCW address type
The native bus for s390 I/O is called CCW (channel command word).
As QEMU has added basic support for the CCW bus, i.e. the
ability to assign CCW devnos (bus addresses) to devices.
Domains with the new machine type s390-ccw-virtio can use the
CCW bus. Currently QEMU will only allow to define virtio
devices on the CCW bus.
Here we add the new machine type and the new device address to the
schema definition and add a new paragraph to the domain XML
documentation.

Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2013-03-13 16:49:57 -06:00
Eric Blake
374631d016 rng: allow default device in RNG grammar
This matches the documentation of commit 4932ef4, and the
C code changes of commit 75e656a.

* docs/schemas/domaincommon.rng: Allow default entry.
2013-03-07 07:06:53 -07:00
Eric Blake
4932ef4502 rng: restrict passthrough names to known-good files
There is some controversy[1] on the qemu list on whether qemu should
have ever allowed arbitrary file name passthrough, or whether it
should be restricted to JUST /dev/random and /dev/hwrng.  It is
always easier to add support for additional filenames than it is
to remove support for something once released, so this patch
restricts libvirt 1.0.3 (where the virtio-random backend was first
supported) to just the two uncontroversial names, letting us defer
to a later date any decision on whether supporting arbitrary files
makes sense. Additionally, since qemu 1.4 does NOT support
/dev/fdset/nnn fd passthrough for the backend, limiting to just
two known names means that we don't get tempted to try fd
passthrough where it won't work.

[1]https://lists.gnu.org/archive/html/qemu-devel/2013-03/threads.html#00023

* src/conf/domain_conf.c (virDomainRNGDefParseXML): Only allow
/dev/random and /dev/hwrng.
* docs/schemas/domaincommon.rng: Flag invalid files.
* docs/formatdomain.html.in (elementsRng): Document this.
* tests/qemuxml2argvdata/qemuxml2argv-virtio-rng-random.args:
Update test to match.
* tests/qemuxml2argvdata/qemuxml2argv-virtio-rng-random.xml:
Likewise.
2013-03-04 17:45:38 -07:00
Eric Blake
035b0db8ba Revert "S390: Documentation for CCW address type"
This reverts commit 24aa7f8d11.

The implementation to match the documentation is not complete yet,
and the final design might change the name of the 'schid' attribute.
2013-02-26 16:31:27 -07:00
Peter Krempa
fa16c80f52 doc: schema: Add basic documentation for the virtual RNG device support
This patch documents XML elements used for (basic) support of virtual
RNG devices.

In the devices section in the domain XML users may specify:

For the default 'random' backend:
  <devices>
    <rng model='virtio'>
      <backend model='random'>/dev/urandom</backend>
    </rng>
  </devices>

For the slightly more advanced EGD backend:
  <devices>
    <rng model='virtio'>
      <backend model='egd' type='udp'>
        <!-- this is a definition of a character device -->
        <source mode='bind' service='1234'/>
        <source mode='connect' host='1.2.3.4' service='1234'/>
        <!-- or other valid character device configuration -->
      </backend>
    </rng>
  </devices>

For the planned random daemon/pool:
  <devices>
    <rng model='virtio'>
      <backend model='pool' pool='poolname'>class</backend>
    </rng>
  </devices>

to enable the RNG device for guests.
2013-02-25 10:17:35 +01:00
Viktor Mihajlovski
24aa7f8d11 S390: Documentation for CCW address type
The native bus for s390 I/O is called CCW (channel command word).
As QEMU has added basic support for the CCW bus, i.e. the
ability to assign CCW devnos (bus addresses) to devices.
Domains with the new machine type s390-ccw-virtio can use the
CCW bus. Currently QEMU will only allow to define virtio
devices on the CCW bus.
Here we add the new machine type and the new device address to the
schema definition and add a new paragraph to the domain XML
documentation.

Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2013-02-11 16:27:45 -07:00
Josh Durgin
c1509ab47e qemu: escape ipv6 for rbd network disk hosts
Hosts for rbd are ceph monitor daemons. These have fixed IP addresses,
so they are often referenced by IP rather than hostname for
convenience, or to avoid relying on DNS. Using IPv4 addresses as the
host name works already, but IPv6 addresses require rbd-specific
escaping because the colon is used as an option separator in the
string passed to qemu.

Escape these colons, and enclose the IPv6 address in square brackets
so it is distinguished from the port, which is currently mandatory.

Acked-by: Osier Yang <jyang@redhat.com>
Signed-off-by: Josh Durgin <josh.durgin@inktank.com>
2013-01-25 11:48:24 +08:00
Peter Krempa
14940b5eaa schema: Make the cpuset type reusable across schema files 2013-01-24 10:53:00 +01:00
Alon Levy
55bfd020d8 qemu: Support ram bar size for qxl devices
Adds a "ram" attribute globally to the video.model element, that changes
the resulting qemu command line only if video.type == "qxl".

<video>
  <model type='qxl' ram='65536' vram='65536' heads='1'/>
</video>

That attribute gets a default value of 64*1024. The schema is unchanged
for other video element types.

The resulting qemu command line change is the addition of

-global qxl-vga.ram_size=<ram>*1024

or

-global qxl.ram_size=<ram>*1024

For the main and secondary qxl devices respectively.

The default for the qxl ram bar is 64*1024 kilobytes (the same as the
default qxl vram bar size).
2013-01-22 10:40:45 -07:00
Guannan Ren
e3a04455fa qemu: add usb-serial support
Add an optional 'type' attribute to <target> element of serial port
device. There are two choices for its value, 'isa-serial' and
'usb-serial'. For backward compatibility, when attribute 'type' is
missing the 'isa-serial' will be chosen as before.

Libvirt XML sample

    <serial type='pty'>
      <target type='usb-serial' port='0'/>
      <address type='usb' bus='0' port='1'/>
    </serial>

qemu commandline:

qemu ${other_vm_args}              \
    -chardev pty,id=charserial0    \
    -device usb-serial,chardev=charserial0,id=serial0,bus=usb.0,port=1
2013-01-10 21:29:20 +08:00
J.B. Joret
d760255d01 S390: Add SCLP console front end support
The SCLP console is the native console type for s390 and is preferred
over the virtio console as it doesn't require special drivers and
is more efficient. Recent versions of QEMU come with SCLP support
which is hereby enabled.

The new target types 'sclp' and 'sclplm' can be used to specify a
SCLP console. Adding documentation, domain schema and XML processing
support.

Signed-off-by: J.B. Joret <jb@linux.vnet.ibm.com>
Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2013-01-08 11:37:52 +01:00
Osier Yang
b9c57e7b0d docs: Add docs and rng schema for new XML tag sgio
This introduces new XML tag "sgio" for disk, its valid values
are "filtered" and "unfiltered", setting it as "filtered" will
set the disk's unpriv_sgio to 0, and "unfiltered" to set it
as 1, which allows the unprivileged SG_IO commands.
2013-01-07 21:37:24 +08:00
Daniel P. Berrange
aae0fc2a92 Add support for <hostdev mode="capabilities">
The <hostdev> device type has long had a redundant "mode"
attribute, which has always been "subsys". This finally
introduces a new mode "capabilities", which will be used
by the LXC driver for device assignment. Since container
based virtualization uses a single kernel, the idea of
assigning physical PCI devices doesn't make sense. It is
still reasonable to assign USB devices, but for assigning
arbitrary nodes in /dev, the new 'capabilities' mode is
to be used.

The first capability support is 'storage', which is for
assignment of block devices. Functionally this is really
pretty similar to the <disk> support. The only difference
is the device node name is identical in both host and
container namespaces.

    <hostdev mode='capabilities' type='storage'>
      <source>
        <block>/dev/sdf1</block>
      </source>
    </hostdev>

The second capability support is 'misc', which is for
assignment of character devices. There is no existing
parallel to this. Again the device node is the same
inside & outside the container.

    <hostdev mode='capabilities' type='misc'>
      <source>
        <char>/dev/input/event3</char>
      </source>
    </hostdev>

The reason for keeping the char & storage devices
separate in the domain XML, is to mirror the split
in the node device XML. NB the node device XML does
not yet report character devices, but that's another
new patch to come

Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2012-12-17 17:50:50 +00:00
Guannan Ren
09938bb3b0 conf: add optional attribte primary to video <model> element
If there are multiple video devices
primary = 'yes' marks this video device as the primary one.
The rest are secondary video devices. No more than one could be
mark as primary. If none of them has primary attribute, the first
one will be the primary by default like what it was.
The reason of this changing is that for qemu, only one primary video
device is permitted which can be of any type. For secondary video
devices, only qxl is allowd. Primary attribute removes the restriction
that the first have to be the primary one.

We always put the primary video device into the first position of
video device structure array after parsing.
2012-12-17 14:01:20 +08:00
Osier Yang
b718ded39a qemu: Allow the user to specify vendor and product for disk
QEMU supports setting vendor and product strings for disk since
1.2.0 (only scsi-disk, scsi-hd, scsi-cd support it), this patch
exposes it with new XML elements <vendor> and <product> of disk
device.
2012-12-07 16:53:27 +08:00
Harsh Prateek Bora
a2d2b80fbd Add Gluster protocol as supported network disk backend
This patch introduces the RNG schema and updates necessary data strucutures
to allow various hypervisors to make use of Gluster protocol as one of the
supported network disk backend. Next patch will add support to make use of
this feature in Qemu since it now supports Gluster protocol as one of the
network based storage backend.

Two new optional attributes for <host> element are introduced - 'transport'
and 'socket'. Valid transport values are tcp, unix or rdma. If none specified,
tcp is assumed. If transport is unix, socket specifies path to unix socket.

This patch allows users to specify disks on gluster backends like this:

    <disk type='network' device='disk'>
      <driver name='qemu' type='raw'/>
      <source protocol='gluster' name='Volume1/image'>
        <host name='example.org' port='6000' transport='tcp'/>
      </source>
      <target dev='vda' bus='virtio'/>
    </disk>

    <disk type='network' device='disk'>
      <driver name='qemu' type='raw'/>
      <source protocol='gluster' name='Volume2/image'>
        <host transport='unix' socket='/path/to/sock'/>
      </source>
      <target dev='vdb' bus='virtio'/>
    </disk>

Signed-off-by: Harsh Prateek Bora <harsh@linux.vnet.ibm.com>
2012-11-27 10:19:22 +01:00
Ján Tomko
a4c19459aa qemu: add bootindex for usb-host and usb-redir devices
Allow bootindex to be specified for redirected USB devices and host USB
devices.

Bug: https://bugzilla.redhat.com/show_bug.cgi?id=805414
2012-11-14 19:03:18 -07:00
Eric Blake
e2c41e4860 storage: match RNG to supported driver types
At one point, the code passed through arbitrary strings for file
formats, which supposedly lets qemu handle a new file type even
before libvirt has been taught to handle it.  However, to properly
label files, libvirt has to learn the file type anyway, so we
might as well make our life easier by only accepting file types
that we are prepared to handle.  This patch lets the RNG validation
ensure that only known strings are let through.

* docs/schemas/domaincommon.rng (driverFormat): Limit to list of
supported strings.
* docs/schemas/domainsnapshot.rng (driver): Likewise.
2012-10-19 17:35:09 -06:00
Peter Krempa
cc922fddc3 conf: Add support for HyperV Enlightenment features
Hypervisors are starting to support HyperV Enlightenment features that
improve behavior of guests running Microsoft Windows operating systems.

This patch adds support for the "relaxed" feature that improves timer
behavior and also establishes a framework to add these features in
future.
2012-10-18 12:22:50 +02:00
Jiri Denemark
f95560b3fe conf: Mark missing optional USB devices in domain XML
When startupPolicy set for a USB devices allows such device to be
missing, there was no way this could be detected from domain XML. With
this patch, libvirt emits a new missing='yes' attribute for such devices
when active domain XML is generated.
2012-10-12 10:55:32 +02:00
Jiri Denemark
e658daeb58 conf: Add support for startupPolicy for USB devices
USB devices can disappear without OS being mad about it, which makes
them ideal for startupPolicy. With this attribute, USB devices can be
configured to be mandatory (the default), requisite (will disappear
during migration if they cannot be found), or completely optional.
2012-10-11 15:11:41 +02:00
Jiri Denemark
76f5bcabe6 conf: Add on_lockfailure event configuration
Using this new element, one can configure an action that should be
performed when resource locks are lost.
2012-10-11 14:41:41 +02:00
Jiri Denemark
d0ea530b00 conf: Rename life cycle actions to event actions
While current on_{poweroff,reboot,crash} action configuration is about
configuring life cycle actions, they can all be considered events and
actions that need to be done on a particular event. Let's generalize the
code by renaming life cycle actions to event actions so that it can be
reused later for non-lifecycle events.
2012-10-11 14:40:54 +02:00
Richard W.M. Jones
f8b08d0e96 Add <seclabel> to character devices.
This allows the user to control labelling of each character device
separately (the default is to inherit from the VM).

Signed-off-by: Richard W.M. Jones <rjones@redhat.com>
2012-09-21 13:43:47 +01:00
Martin Kletzander
78f3666fe9 Add support for limiting guest coredump
Sometimes when guest machine crashes, coredump can get huge due to the
guest memory. This can be limited using madvise(2) system call and is
being used in QEMU hypervisor. This patch adds an option for configuring
that in the domain XML and related documentation.
2012-09-20 16:41:07 +02:00
Martin Kletzander
c33a922faa Add support for reboot-timeout
Whenever the guest machine fails to boot, new parameter (reboot-timeout)
controls whether it should reboot and after how many ms it should do so.

Docs included.
2012-09-20 16:41:01 +02:00
Osier Yang
dbb7df1f81 schema: Add schema for disk <wwn>
* docs/formatdomain.html.in: Add document.
* docs/schemas/nodedev.rng: Move definition of "wwn" to ...
* docs/schemas/basictypes.rng: ...Here
* docs/schemas/domaincommon.rng: Add schema for disk <wwn>
2012-09-18 14:42:29 +08:00
Martin Kletzander
4a8b7cba80 Add support for EOI with APIC
New options is added to support EOI (End of Interrupt) exposure for
guests. As it makes sense only when APIC is enabled, I added this into
the <apic> element in <features> because this should be tri-state
option (cannot be handled as standalone feature).
2012-09-14 08:18:11 +02:00
Guannan Ren
1c9d485dda test: add xml2argvtest for usb-redir filter and update xml schema 2012-09-13 17:22:37 +08:00
Viktor Mihajlovski
72f1f2206e Rename iolimit to blockio.
After discussion with DB we decided to rename the new iolimit
element as it creates the impression it would be there to
limit (i.e. throttle) I/O instead of specifying immutable
characteristics of a block device.
This is also backed by the fact that the term I/O Limits has
vanished from newer storage admin documentation.

Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2012-09-04 09:14:36 -06:00
Martin Kletzander
09cd8f2ddf Add per-guest S3/S4 state configuration
There is a new <pm/> element implemented that can control what ACPI
sleeping states will be advertised by BIOS and allowed to be switched
to by libvirt. The default keeps defaults on hypervisor, otherwise
forces chosen setting.
The documentation of the pm element is added as well.
2012-09-03 09:08:21 +02:00
Viktor Mihajlovski
5cc50ad7a4 conf: Support for Block Device IO Limits
Introducing a new iolimits element allowing to override certain
properties of a guest block device like the physical and logical
block size.
This can be useful for platforms with 'non-standard' disk formats
like S390 DASD with its 4K block size.

Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2012-08-31 11:27:27 -07:00
Hu Tao
b65dafa812 qemu: introduce period/quota tuning for emulator
This patch introduces support of setting emulator's period and
quota to limit cpu bandwidth when the vm starts.  Also updates
XML Schema for new entries and docs.
2012-08-22 16:52:22 +08:00
Tang Chen
19630db3e3 Support emulatorpin xml parse.
This patch adds a new xml element <emulatorpin>, which is a sibling
to the existing <vcpupin> element under the <cputune>, to pin emulator
threads to specified physical CPUs.

Signed-off-by: Tang Chen <tangchen@cn.fujitsu.com>
Signed-off-by: Hu Tao <hutao@cn.fujitsu.com>
2012-08-22 15:51:23 +08:00
J.B. Joret
5d4f8d9746 Support for Disk Geometry Override
A hypervisor may allow to override the disk geometry of drives.
Qemu, as an example with cyls=,heads=,secs=[,trans=].
This patch extends the domain config to allow the specification of
disk geometry with libvirt.

Signed-off-by: J.B. Joret <jb@linux.vnet.ibm.com>
Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2012-08-21 15:30:07 -06:00
Marcelo Cerri
e9377dda36 Multiple security drivers in XML data
This patch updates the domain and capability XML parser and formatter to
support more than one "seclabel" element for each domain and device. The
RNG schema and the tests related to this are also updated by this patch.

Signed-off-by: Marcelo Cerri <mhcerri@linux.vnet.ibm.com>
2012-08-20 19:13:33 +02:00
Shradha Shah
1446003419 conf: parser/formatter/rng for <forward mode='hostdev'>
This patch introduces the new forward mode='hostdev' along with
attribute managed. Includes updates to the network RNG and new xml
parser/formatter code.

Signed-off-by: Shradha Shah <sshah@solarflare.com>
2012-08-17 15:43:26 -04:00
Laine Stump
3f9274a524 conf: add <vlan> element to network and domain interface elements
The following config elements now support a <vlan> subelements:

within a domain: <interface>, and the <actual> subelement of <interface>
within a network: the toplevel, as well as any <portgroup>

Each vlan element must have one or more <tag id='n'/> subelements.  If
there is more than one tag, it is assumed that vlan trunking is being
requested. If trunking is required with only a single tag, the
attribute "trunk='yes'" should be added to the toplevel <vlan>
element.

Some examples:

  <interface type='hostdev'/>
    <vlan>
      <tag id='42'/>
    </vlan>
    <mac address='52:54:00:12:34:56'/>
    ...
  </interface>

  <network>
    <name>vlan-net</name>
    <vlan trunk='yes'>
      <tag id='30'/>
    </vlan>
    <virtualport type='openvswitch'/>
  </network>

  <interface type='network'/>
    <source network='vlan-net'/>
    ...
  </interface>

  <network>
    <name>trunk-vlan</name>
    <vlan>
      <tag id='42'/>
      <tag id='43'/>
    </vlan>
    ...
  </network>

  <network>
    <name>multi</name>
    ...
    <portgroup name='production'/>
      <vlan>
        <tag id='42'/>
      </vlan>
    </portgroup>
    <portgroup name='test'/>
      <vlan>
        <tag id='666'/>
      </vlan>
    </portgroup>
  </network>

  <interface type='network'/>
    <source network='multi' portgroup='test'/>
    ...
  </interface>

IMPORTANT NOTE: As of this patch there is no backend support for the
vlan element for *any* network device type. When support is added in
later patches, it will only be for those select network types that
support setting up a vlan on the host side, without the guest's
involvement. (For example, it will be possible to configure a vlan for
a guest connected to an openvswitch bridge, but it won't be possible
to do that for one that is connected to a standard Linux host bridge.)
2012-08-15 13:10:57 -04:00
Laine Stump
e4a199a1af schema: fix some problems in network/interface schemas
<portgroup> allows a <bandwidth> element, but the schema didn't have
this. Since this makes for multiple elements in portgroup, they must
be interleaved.

<interface type='bridge'> needs to allow <virtualport> elements
for openvswitch, but the schema didn't allow this.
2012-08-15 13:10:57 -04:00
Dmitry Guryanov
9700ca82fe parallels: add domain configuration example
Signed-off-by: Dmitry Guryanov <dguryanov@parallels.com>
2012-08-15 16:39:40 +08:00
Peter Krempa
0925189713 domain_conf: Add USB controler model "none"
Libvirt adds a USB controller to the guest even if the user does not
specify any in the XML. This is due to back-compat reasons.

To allow disabling USB for a guest this patch adds a new USB controller
type "none" that disables USB support for the guest.
2012-08-02 11:54:14 +02:00
Viktor Mihajlovski
1af7e319ed S390: Domain Schema for s390-virtio machines.
Added s390-virtio machine type to the XML schema for domains in order
to not fail the domain schema tests.

Signed-off-by: Viktor Mihajlovski <mihajlov@linux.vnet.ibm.com>
2012-07-11 11:19:05 +02:00
Hendrik Schwartke
a3389319ba Added the attribute vendor_id to the cpu model
Introducing the attribute vendor_id to force the CPUID instruction
in a kvm guest to return the specified vendor.
2012-07-03 12:06:38 +02:00
Daniel P. Berrange
3b1ddec1ef Add support for guest bind mounts with LXC
Currently you can configure LXC to bind a host directory to
a guest directory, but not to bind a guest directory to a
guest directory. While the guest container init could do
this itself, allowing it in the libvirt XML means a stricter
SELinux policy can be written
2012-06-25 10:17:56 +01:00
Daniel P. Berrange
76b644c362 Add support for RAM filesystems for LXC
Introduce a new syntax for filesystems to allow use of a RAM
filesystem

   <filesystem type='ram'>
      <source usage='10' units='MiB'/>
      <target dir='/mnt'/>
   </filesystem>

The usage units default to KiB to limit consumption of host memory.

* docs/formatdomain.html.in: Document new syntax
* docs/schemas/domaincommon.rng: Add new attributes
* src/conf/domain_conf.c: Parsing/formatting of RAM filesystems
* src/lxc/lxc_container.c: Mounting of RAM filesystems

Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
2012-06-25 10:17:56 +01:00
Gerd Hoffmann
fd4fd420b4 qemu: Add xhci support
qemu 1.1 features a xhci controller,
this patch adds support for it.

Signed-off-by: Gerd Hoffmann <kraxel@redhat.com>
2012-06-21 16:33:00 +02:00
Osier Yang
b34324fbf0 schema: Update domain XML schema
'boot' tag shouldn't be exclusive with 'kernel', 'initrd', and 'cmdline',
though the boot sequence doesn't make sense when the guest boots from
kernel directly. But it's useful if booting from kernel is to install
a newguest, even if it's not to install a guest, there is no hurt. And
on the other hand, we allow 'boot' and the kernel tags when parsing.
2012-06-15 21:56:48 +08:00
Guido Günther
41f1db6a0c Introduce filesystem limits to virDomainFSDef 2012-05-24 11:35:02 +02:00
Marc-André Lureau
988e85a51e domain: add <codec> sound sub-element
Allow specifying sound device codecs. See formatdomain.html for
more details.
2012-05-17 11:40:11 -06:00
Osier Yang
97010eb1f1 numad: Set memory policy from numad advisory nodeset
Though numad will manage the memory allocation of task dynamically,
it wants management application (libvirt) to pre-set the memory
policy according to the advisory nodeset returned from querying numad,
(just like pre-bind CPU nodeset for domain process), and thus the
performance could benefit much more from it.

This patch introduces new XML tag 'placement', value 'auto' indicates
whether to set the memory policy with the advisory nodeset from numad,
and its value defaults to the value of <vcpu> placement, or 'static'
if 'nodeset' is specified. Example of the new XML tag's usage:

  <numatune>
    <memory placement='auto' mode='interleave'/>
  </numatune>

Just like what current "numatune" does, the 'auto' numa memory policy
setting uses libnuma's API too.

If <vcpu> "placement" is "auto", and <numatune> is not specified
explicitly, a default <numatume> will be added with "placement"
set as "auto", and "mode" set as "strict".

The following XML can now fully drive numad:

1) <vcpu> placement is 'auto', no <numatune> is specified.

   <vcpu placement='auto'>10</vcpu>

2) <vcpu> placement is 'auto', no 'placement' is specified for
   <numatune>.

   <vcpu placement='auto'>10</vcpu>
   <numatune>
     <memory mode='interleave'/>
   </numatune>

And it's also able to control the CPU placement and memory policy
independently. e.g.

1) <vcpu> placement is 'auto', and <numatune> placement is 'static'

   <vcpu placement='auto'>10</vcpu>
   <numatune>
     <memory mode='strict' nodeset='0-10,^7'/>
   </numatune>

2) <vcpu> placement is 'static', and <numatune> placement is 'auto'

   <vcpu placement='static' cpuset='0-24,^12'>10</vcpu>
   <numatune>
     <memory mode='interleave' placement='auto'/>
   </numatume>

A follow up patch will change the XML formatting codes to always output
'placement' for <vcpu>, even it's 'static'.
2012-05-08 16:57:32 -06:00
Alon Levy
ba97e4edc6 domain_conf: add "default" to list of valid spice channels
qemu's behavior in this case is to change the spice server behavior to
require secure connection to any channel not otherwise specified as
being in plaintext mode. libvirt doesn't currently allow requesting this
(via plaintext-channel=<channel name>).

RHBZ: 819499

Signed-off-by: Alon Levy <alevy@redhat.com>
2012-05-08 12:14:45 -06:00
Alon Levy
4e78ffb634 domain_conf: add "usbredir" to list of valid spice channels
Add "usbredir" channel to list of recognized spice channels.

RHBZ: 819498

Signed-off-by: Alon Levy <alevy@redhat.com>
2012-05-08 09:22:45 -06:00
Eric Blake
ae6aa8c396 blockjob: enhance xml to track mirrors across libvirtd restart
In order to track a block copy job across libvirtd restarts, we
need to save internal XML that tracks the name of the file
holding the mirror.  Displaying this name in dumpxml might also
be useful to the user, even if we don't yet have a way to (re-)
start a domain with mirroring enabled up front.  This is done
with a new <mirror> sub-element to <disk>, as in:

    <disk type='file' device='disk'>
      <driver name='qemu' type='raw'/>
      <source file='/var/lib/libvirt/images/original.img'/>
      <mirror file='/var/lib/libvirt/images/copy.img' format='qcow2' ready='yes'/>
      ...
    </disk>

For now, the element is output-only, in live domains; it is ignored
when defining a domain or hot-plugging a disk (since those contexts
use VIR_DOMAIN_XML_INACTIVE in parsing).  The 'ready' attribute appears
when libvirt knows that the job has changed from the initial pulling
phase over to the mirroring phase, although absence of the attribute
is not a sure indicator of the current phase.  If we come up with a way
to make qemu start with mirroring enabled, we can relax the xml
restriction, and allow <mirror> (but not attribute 'ready') on input.
Testing active-only XML meant tweaking the testsuite slightly, but it
was worth it.

* docs/schemas/domaincommon.rng (diskspec): Add diskMirror.
* docs/formatdomain.html.in (elementsDisks): Document it.
* src/conf/domain_conf.h (_virDomainDiskDef): New members.
* src/conf/domain_conf.c (virDomainDiskDefFree): Clean them.
(virDomainDiskDefParseXML): Parse them, but only internally.
(virDomainDiskDefFormat): Output them.
* tests/qemuxml2argvdata/qemuxml2argv-disk-mirror.xml: New test file.
* tests/qemuxml2xmloutdata/qemuxml2xmlout-disk-mirror.xml: Likewise.
* tests/qemuxml2xmltest.c (testInfo): Alter members.
(testCompareXMLToXMLHelper): Allow more test control.
(mymain): Run new test.
2012-04-23 08:43:33 -06:00
Osier Yang
7adeac67e8 docs: Improve the schema for fs device
<filesystemtgt> is redundant, as every group uses it; <address>
shouldn't be in <filesystemtgt> in case of the meaning could be
"filesystemtarget"; The elements <address>, <alias>, <target>,
... should be interleaved.
2012-04-18 00:39:45 +08:00
Philipp Hahn
b8bf79aad7 Support clock=variable relative to localtime
Since Xen 3.1 the clock=variable semantic is supported. In addition to
qemu/kvm Xen also knows about a variant where the offset is relative to
'localtime' instead of 'utc'.

Extends the libvirt structure with a flag 'basis' to specify, if the
offset is relative to 'localtime' or 'utc'.

Extends the libvirt structure with a flag 'reset' to force the reset
behaviour of 'localtime' and 'utc'; this is needed for backward
compatibility with previous versions of libvirt, since they report
incorrect XML.

Adapt the only user 'qemu' to the new name.
Extend the RelaxNG schema accordingly.
Document the new 'basis' attribute in the HTML documentation.
Adapt test for the new attribute.

Signed-off-by: Philipp Hahn <hahn@univention.de>
2012-04-02 09:08:31 -06:00
Daniel P. Berrange
72c507317a Add LXC XML files to schema test & fix problems this uncovers
* docs/schemas/domaincommon.rng: Add missing lxc & openvz
  console target types. Allow arch on LXC <os> type element
* tests/domainschematest: Include tests/lxcxml2xmldata/
2012-03-27 15:52:25 +01:00
Daniel P. Berrange
c91cff255f Add support for setting init argv for LXC
Pass argv to the init binary of LXC, using a new <initarg> element.

* docs/formatdomain.html.in: Document <os> usage for containers
* docs/schemas/domaincommon.rng: Add <initarg> element
* src/conf/domain_conf.c, src/conf/domain_conf.h: parsing and
  formatting of <initarg>
* src/lxc/lxc_container.c: Setup LXC argv
* tests/Makefile.am, tests/lxcxml2xmldata/lxc-systemd.xml,
  tests/lxcxml2xmltest.c, tests/testutilslxc.c,
  tests/testutilslxc.h: Test parsing/formatting of LXC related
  XML parts
2012-03-27 15:52:25 +01:00
Osier Yang
ab49b392cc docs: Add documentation for new attribute tray of disk target
Example XML:

    <disk type='file' device='cdrom'>
      <driver name='qemu' type='raw'/>
      <source file='/tmp/cdrom.img'/>
      <target dev='hdd' bus='ide' tray='open'/>
    </disk>
2012-03-23 23:10:30 +08:00
Laine Stump
0007237301 conf: forbid use of multicast mac addresses
A few times libvirt users manually setting mac addresses have
complained of a networking failure that ends up being due to a multicast
mac address being used for a guest interface. This patch prevents that
by logging an error and failing if a multicast mac address is
encountered in each of the three following cases:

1) domain xml <interface> mac address.
2) network xml bridge mac address.
3) network xml dhcp/host mac address.

There are several other places where a mac address can be input that
aren't controlled in this manner because failure to do so has no
consequences (e.g., if the address will be used to search through
existing interfaces for a match).

The RNG has been updated to add multiMacAddr and uniMacAddr along with
the existing macAddr, and macAddr was switched to uniMacAddr where
appropriate.
2012-03-19 20:33:30 -04:00
Daniel P. Berrange
10a8b1f958 Add support for forcing a private network namespace for LXC guests
If no <interface> elements are included in an LXC guest XML
description, then the LXC guest will just see the host's
network interfaces. It is desirable to be able to hide the
host interfaces, without having to define any guest interfaces.

This patch introduces a new feature flag <privnet/> to allow
forcing of a private network namespace for LXC. In the future
I also anticipate that we will add <privuser/> to force a
private user ID namespace.

* src/conf/domain_conf.c, src/conf/domain_conf.h: Add support
  for <privnet/> feature. Auto-set <privnet> if any <interface>
  devices are defined
* src/lxc/lxc_container.c: Honour request for private network
  namespace
2012-03-15 17:00:39 +00:00
Osier Yang
0f8e7ae33a qemu: Support numad
numad is an user-level daemon that monitors NUMA topology and
processes resource consumption to facilitate good NUMA resource
alignment of applications/virtual machines to improve performance
and minimize cost of remote memory latencies. It provides a
pre-placement advisory interface, so significant processes can
be pre-bound to nodes with sufficient available resources.

More details: http://fedoraproject.org/wiki/Features/numad

"numad -w ncpus:memory_amount" is the advisory interface numad
provides currently.

This patch add the support by introducing a new XML attribute
for <vcpu>. e.g.

  <vcpu placement="auto">4</vcpu>
  <vcpu placement="static" cpuset="1-10^6">4</vcpu>

The returned advisory nodeset from numad will be printed
in domain's dumped XML. e.g.
  <vcpu placement="auto" cpuset="1-10^6">4</vcpu>

If placement is "auto", the number of vcpus and the current
memory amount specified in domain XML will be used for numad
command line (numad uses MB for memory amount):
  numad -w $num_of_vcpus:$current_memory_amount / 1024

The advisory nodeset returned from numad will be used to set
domain process CPU affinity then. (e.g. qemuProcessInitCpuAffinity).

If the user specifies both CPU affinity policy (e.g.
(<vcpu cpuset="1-10,^7,^8">4</vcpu>) and placement == "auto"
the specified CPU affinity will be overridden.

Only QEMU/KVM drivers support it now.

See docs update in patch for more details.
2012-03-15 12:24:56 +08:00
Peng Zhou
896e6ac4f8 qemu: spice agent-mouse support
spice agent-mouse support

Usage:
  <graphics type='spice'>
    <mouse mode='client'|'server'/>
  <graphics/>

Signed-off-by: Osier Yang <jyang@redhat.com>
2012-03-09 15:26:24 +08:00
Eric Blake
2e22f23bde xml: allow scaled memory on input
Output is still in kibibytes, but input can now be in different
scales for ease of typing.

* src/conf/domain_conf.c (virDomainParseMemory): New helper.
(virDomainDefParseXML): Use it when parsing.
* docs/schemas/domaincommon.rng: Expand XML; rename memoryKBElement
to memoryElement and update callers.
* docs/formatdomain.html.in (elementsMemoryAllocation): Document
scaling.
* tests/qemuxml2argvdata/qemuxml2argv-memtune.xml: Adjust test.
* tests/qemuxml2xmltest.c: Likewise.
* tests/qemuxml2xmloutdata/qemuxml2xmlout-memtune.xml: New file.
2012-03-07 18:24:44 -07:00
Eric Blake
1b1402b90f xml: drop unenforced minimum memory limit from RNG
The test domain allows <memory>0</memory>, but the RNG was stating
that memory had to be at least 4096000 bytes.  Hypervisors should
enforce their own limits, rather than complicating the RNG.

Meanwhile, some copy and paste had introduced some fishy constructs
in various unit tests.

* docs/schemas/domaincommon.rng (memoryKB, memoryKBElement): Drop
limit that isn't enforced in code.
* src/conf/domain_conf.c (virDomainDefParseXML): Require current
<= maximum.
* tests/qemuxml2argvdata/*.xml: Fix offenders.
2012-03-07 18:24:43 -07:00
Eric Blake
265457845f xml: output memory unit for clarity
Make it obvious to 'dumpxml' readers what unit we are using,
since our default of KiB for memory (1024) differs from qemu's
default of MiB; and differs from our use of bytes for storage.

Tests were updated via:

$ find tests/*data tests/*out -name '*.xml' | \
  xargs sed -i 's/<\(memory\|currentMemory\|hard_limit\|soft_limit\|min_guarantee\|swap_hard_limit\)>/<\1 unit='"'KiB'>/"
$ find tests/*data tests/*out -name '*.xml' | \
  xargs sed -i 's/<\(capacity\|allocation\|available\)>/<\1 unit='"'bytes'>/"

followed by a few fixes for the stragglers.

Note that with this patch, the RNG for <memory> still forbids
validation of anything except unit='KiB', since the code silently
ignores the attribute; a later patch will expand <memory> to allow
scaled input in the code and update the RNG to match.

* docs/schemas/basictypes.rng (unit): Add 'bytes'.
(scaledInteger): New define.
* docs/schemas/storagevol.rng (sizing): Use it.
* docs/schemas/storagepool.rng (sizing): Likewise.
* docs/schemas/domaincommon.rng (memoryKBElement): New define; use
for memory elements.
* src/conf/storage_conf.c (virStoragePoolDefFormat)
(virStorageVolDefFormat): Likewise.
* src/conf/domain_conf.h (_virDomainDef): Document unit used
internally.
* src/conf/storage_conf.h (_virStoragePoolDef, _virStorageVolDef):
Likewise.
* tests/*data/*.xml: Update all tests.
* tests/*out/*.xml: Likewise.
* tests/define-dev-segfault: Likewise.
* tests/openvzutilstest.c (testReadNetworkConf): Likewise.
* tests/qemuargv2xmltest.c (blankProblemElements): Likewise.
2012-03-07 18:24:43 -07:00
Laine Stump
3b1c191fe7 conf: parse/format type='hostdev' network interfaces
This is the new interface type that sets up an SR-IOV PCI network
device to be assigned to the guest with PCI passthrough after
initializing some network device-specific things from the config
(e.g. MAC address, virtualport profile parameters). Here is an example
of the syntax:

  <interface type='hostdev' managed='yes'>
    <source>
      <address type='pci' domain='0' bus='0' slot='4' function='3'/>
    </source>
    <mac address='00:11:22:33:44:55'/>
    <address type='pci' domain='0' bus='0' slot='7' function='0'/>
  </interface>

This would assign the PCI card from bus 0 slot 4 function 3 on the
host, to bus 0 slot 7 function 0 on the guest, but would first set the
MAC address of the card to 00:11:22:33:44:55.

NB: The parser and formatter don't care if the PCI card being
specified is a standard single function network adapter, or a virtual
function (VF) of an SR-IOV capable network adapter, but the upcoming
code that implements the back end of this config will work *only* with
SR-IOV VFs. This is because modifying the mac address of a standard
network adapter prior to assigning it to a guest is pointless - part
of the device reset that occurs during that process will reset the MAC
address to the value programmed into the card's firmware.

Although it's not supported by any of libvirt's hypervisor drivers,
usb network hostdevs are also supported in the parser and formatter
for completeness and consistency. <source> syntax is identical to that
for plain <hostdev> devices, except that the <address> element should
have "type='usb'" added if bus/device are specified:

  <interface type='hostdev'>
    <source>
      <address type='usb' bus='0' device='4'/>
    </source>
    <mac address='00:11:22:33:44:55'/>
  </interface>

If the vendor/product form of usb specification is used, type='usb'
is implied:

  <interface type='hostdev'>
    <source>
      <vendor id='0x0012'/>
      <product id='0x24dd'/>
    </source>
    <mac address='00:11:22:33:44:55'/>
  </interface>

Again, the upcoming patch to fill in the backend of this functionality
will log an error and fail with "Unsupported Config" if you actually
try to assign a USB network adapter to a guest using <interface
type='hostdev'> - just use a standard <hostdev> entry in that case
(and also for single-port PCI adapters).
2012-03-05 23:24:28 -05:00
Osier Yang
4288b22fb2 conf: Introduce new attribute for device address format
* src/conf/domain_conf.h: Add new member "target" to struct
  _virDomainDeviceDriveAddress.

* src/conf/domain_conf.c: Parse and format "target"

* Lots of tests (.xml) in tests/domainsnapshotxml2xmlout,
  tests/qemuxml2argvdata, tests/qemuxml2xmloutdata, and
  tests/vmx2xmldata/ are modified for newly introduced
  attribute "target" for address of "drive" type.
2012-02-28 14:27:11 +08:00
Paolo Bonzini
8dcac770f1 qemu: add virtio-scsi controller model
Adding a new model for virtio-scsi roughly follows the same scheme
as the previous patch.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2012-02-28 14:27:03 +08:00
Paolo Bonzini
3482191d12 qemu: add ibmvscsi controller model
KVM will be able to use a PCI SCSI controller even on POWER.  Let
the user specify the vSCSI controller by other means than a default.

After this patch, the QEMU driver will actually look at the model
and reject anything but auto, lsilogic and ibmvscsi.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
Signed-off-by: Osier Yang <jyang@redhat.com>
2012-02-28 14:27:00 +08:00
Daniel Veillard
ded8e894dd Revert "qemu: add ibmvscsi controller model"
This reverts commit 7b345b69f2.

Conflicts:

	tests/qemuxml2argvdata/qemuxml2argv-disk-scsi-vscsi.xml
2012-02-13 21:37:03 +08:00
Daniel Veillard
3d224ae669 Revert "qemu: add virtio-scsi controller model"
This reverts commit c9abfadf37.

Conflicts:

	tests/qemuxml2argvdata/qemuxml2argv-disk-scsi-virtio-scsi.xml
2012-02-13 21:36:02 +08:00
Eric Blake
c052d8a89f seclabel: make code and RNG match
Commit b170eb99 introduced a bug: domains that had an explicit
<seclabel type='none'/> when started would not be reparsed if
libvirtd restarted.  It turns out that our testsuite was not
exercising this because it never tried anything but inactive
parsing.  Additionally, the live XML for such a domain failed
to re-validate.  Applying just the tests/ portion of this patch
will expose the bugs that are fixed by the other two files.

* docs/schemas/domaincommon.rng (seclabel): Allow relabel under
type='none'.
* src/conf/domain_conf.c (virSecurityLabelDefParseXML): Per RNG,
presence of <seclabel> with no type implies dynamic.  Don't
require sub-elements for type='none'.
* tests/qemuxml2xmltest.c (mymain): Add test.
* tests/qemuxml2argvtest.c (mymain): Likewise.
* tests/qemuxml2argvdata/qemuxml2argv-seclabel-none.xml: Add file.
* tests/qemuxml2argvdata/qemuxml2argv-seclabel-none.args: Add file.
Reported by Ansis Atteka.
2012-02-06 12:04:33 -07:00
Daniel P. Berrange
b170eb99f5 Add two new security label types
Curently security labels can be of type 'dynamic' or 'static'.
If no security label is given, then 'dynamic' is assumed. The
current code takes advantage of this default, and avoids even
saving <seclabel> elements with type='dynamic' to disk. This
means if you temporarily change security driver, the guests
can all still start.

With the introduction of sVirt to LXC though, there needs to be
a new default of 'none' to allow unconfined LXC containers.

This patch introduces two new security label types

 - default:  the host configuration decides whether to run the
             guest with type 'none' or 'dynamic' at guest start
 - none:     the guest will run unconfined by security policy

The 'none' label type will obviously be undesirable for some
deployments, so a new qemu.conf option allows a host admin to
mandate confined guests. It is also possible to turn off default
confinement

  security_default_confined = 1|0  (default == 1)
  security_require_confined = 1|0  (default == 0)

* src/conf/domain_conf.c, src/conf/domain_conf.h: Add new
  seclabel types
* src/security/security_manager.c, src/security/security_manager.h:
  Set default sec label types
* src/security/security_selinux.c: Handle 'none' seclabel type
* src/qemu/qemu.conf, src/qemu/qemu_conf.c, src/qemu/qemu_conf.h,
  src/qemu/libvirtd_qemu.aug: New security config options
* src/qemu/qemu_driver.c: Tell security driver about default
  config
2012-02-02 17:44:37 -07:00
Peter Krempa
b79ba8382e xml: Add element <title> to allow short description of domains
This patch adds a new element <title> to the domain XML. This attribute
can hold a short title defined by the user to ease the identification of
domains. The title may not contain newlines and should be reasonably short.

 *docs/formatdomain.html.in
 *docs/schemas/domaincommon.rng
        - add schema grammar for the new element and documentation
  *src/conf/domain_conf.c
  *src/conf/domain_conf.h
        - add field to hold the new attribute
        - add code to parse and create XML with the new attribute
2012-02-01 14:41:13 -07:00
Eric Blake
c3c2cc6534 build: fix text regression
Commit 8a09ee410 tickles a bug in libxml2-2.7.6 on RHEL 6.2,
where libxml2 treats the pattern [^\n] as excluding literal
backslash and n, instead of the intended newline, thus failing
to validate any domain name containing 'n'.

* docs/schemas/domaincommon.rng: Use literal newline instead.
2012-01-31 16:53:46 -07:00
Taku Izumi
397e6a705b conf: add rawio attribute to disk element of domain XML
This patch adds a new attribute "rawio" to the "disk" element
 of domain XML. Valid values of "rawio" attribute are "yes"
 and "no".
 rawio='yes' indicates the disk is desirous of CAP_SYS_RAWIO.

 If you specify the following XML:

 <disk type='block' device='lun' rawio='yes'>
  ...
 </disk>

 the domain will be granted CAP_SYS_RAWIO.
 (of course, the domain have to be executed with root privilege)

NOTE:
   - "rawio" attribute is only valid when device='lun'
   - At the moment, any other disks you won't use rawio can use rawio.

Signed-off-by: Taku Izumi <izumi.taku@jp.fujitsu.com>
2012-01-31 13:36:23 -05:00
Laine Stump
3801831cdf qemu: add "romfile" support to specify device boot ROM
This patch addresses: https://bugzilla.redhat.com/show_bug.cgi?id=781562

Along with the "rombar" option that controls whether or not a boot rom
is made visible to the guest, qemu also has a "romfile" option that
allows specifying a binary file to present as the ROM BIOS of any
emulated or passthrough PCI device. This patch adds support for
specifying romfile to both passthrough PCI devices, and emulated
network devices that attach to the guest's PCI bus (just about
everything other than ne2k_isa).

One example of the usefulness of this option is described in the
bugzilla report: 82576 sriov network adapters don't provide a ROM BIOS
for the cards virtual functions (VF), but an image of such a ROM is
available, and with this ROM visible to the guest, it can PXE boot.

In libvirt's xml, the new option is configured like this:

   <hostdev>
     ...
     <rom file='/etc/fake/boot.bin'/>
     ...
   </hostdev

(similarly for <interface>).
2012-01-30 12:30:35 -05:00
Laine Stump
3284ac046f qemu: (and conf) support rombar for network devices
When support for the rombar option was added, it was only added for
PCI passthrough devices, configured with <hostdev>. The same option is
available for any network device that is attached to the guest's PCI
bus. This patch allows setting rombar for any PCI network device type.

After adding cases to test this to qemuxml2argv-hostdev-pci-rombar.*,
I decided to rename those files (to qemuxml2argv-pci-rom.*) to more
accurately reflect the additional tests, and also noticed that up to
now we've only been performing a domainschematest for that case, so I
added the "pci-rom" test to both qemuxml2argv and qemuxml2xml (and in
the process found some bugs whose fixes I squashed into previous
commits of this series).
2012-01-30 12:25:32 -05:00
Paolo Bonzini
5a137f3620 conf: add kvmclock timer
Add kvmclock timer to documentation, schema and parsers.  Keep the
platform timer first since it is kind of special, and alphabetize
the others when possible (i.e. when it does not change the ABI).

Reviewed-by: Jiri Denemark <jdenemar@redhat.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2012-01-27 16:51:50 +01:00
Daniel P. Berrange
51a3286f3e Add missing docs for <viridian/> feature flag 2012-01-26 14:23:22 +00:00
Peter Krempa
8a09ee4103 schema: Relax schema for domain name
The domain schema enforced restrictions on the domain name string that
the code doesn't. This patch relaxes the check, leaving the restrictions
on the driver or hypervisor. The only invalid character is a newline.
2012-01-26 14:22:44 +01:00
Zeeshan Ali (Khattak)
fa981fc945 Allow custom metadata in domain configuration XML
Applications can now insert custom nodes and hierarchies into domain
configuration XML. Although currently not enforced, applications are
required to use their own namespaces on every custom node they insert,
with only one top-level element per namespace.
2012-01-24 17:06:34 -07:00
Deepak C Shetty
d9e0d8204b Add new attribute wrpolicy to <driver> element
This introduces new attribute wrpolicy with only supported
value as immediate. This will be an optional
attribute with no defaults. This helps specify whether
to skip the host page cache.

When wrpolicy is specified, meaning when wrpolicy=immediate
a writeback is explicitly initiated for the dirty pages in
the host page cache as part of the guest file write operation.

Usage:
<filesystem type='mount' accessmode='passthrough'>
  <driver type='path' wrpolicy='immediate'/>
  <source dir='/export/to/guest'/>
  <target dir='mount_tag'/>
</filesystem>

Currently this only works with type='mount' for the QEMU/KVM driver.

Signed-off-by: Deepak C Shetty <deepakcs@linux.vnet.ibm.com>
2012-01-17 15:37:42 -07:00
Jiri Denemark
f7dd3a4e62 Add support for cpu mode attribute
The mode can be either of "custom" (default), "host-model",
"host-passthrough". The semantics of each mode is described in the
following examples:

- guest CPU is a default model with specified topology:
    <cpu>
      <topology sockets='1' cores='2' threads='1'/>
    </cpu>

- guest CPU matches selected model:
    <cpu mode='custom' match='exact'>
      <model>core2duo</model>
    </cpu>

- guest CPU should be a copy of host CPU as advertised by capabilities
  XML (this is a short cut for manually copying host CPU specification
  from capabilities to domain XML):
    <cpu mode='host-model'/>

  In case a hypervisor does not support the exact host model, libvirt
  automatically falls back to a closest supported CPU model and
  removes/adds features to match host. This behavior can be disabled by
    <cpu mode='host-model'>
      <model fallback='forbid'/>
    </cpu>

- the same as previous returned by virDomainGetXMLDesc with
  VIR_DOMAIN_XML_UPDATE_CPU flag:
    <cpu mode='host-model' match='exact'>
      <model fallback='allow'>Penryn</model>       --+
      <vendor>Intel</vendor>                         |
      <topology sockets='2' cores='4' threads='1'/>  + copied from
      <feature policy='require' name='dca'/>         | capabilities XML
      <feature policy='require' name='xtpr'/>        |
      ...                                          --+
    </cpu>

- guest CPU should be exactly the same as host CPU even in the aspects
  libvirt doesn't model (such domain cannot be migrated unless both
  hosts contain exactly the same CPUs):
    <cpu mode='host-passthrough'/>

- the same as previous returned by virDomainGetXMLDesc with
  VIR_DOMAIN_XML_UPDATE_CPU flag:
    <cpu mode='host-passthrough' match='minimal'>
      <model>Penryn</model>                        --+ copied from caps
      <vendor>Intel</vendor>                         | XML but doesn't
      <topology sockets='2' cores='4' threads='1'/>  | describe all
      <feature policy='require' name='dca'/>         | aspects of the
      <feature policy='require' name='xtpr'/>        | actual guest CPU
      ...                                          --+
    </cpu>
2012-01-17 11:39:23 +01:00
Jiri Denemark
a6f88cbd2d cpu: Optionally forbid fallback CPU models
In case a hypervisor doesn't support the exact CPU model requested by a
domain XML, we automatically fallback to a closest CPU model the
hypervisor supports (and make sure we add/remove any additional features
if needed). This patch adds 'fallback' attribute to model element, which
can be used to disable this automatic fallback.
2012-01-17 11:39:19 +01:00
Osier Yang
a5f8a01abb docs: Add missed RNG schema for interface
We support <interface> of type "mcast", "server", and "client",
but the RNG schema for them are missed. Attribute "address" is
optional for "server" type. And these 3 types support
<mac address='MAC'/>, too.
2012-01-17 17:09:47 +08:00
Osier Yang
487bdbd8e0 docs: Expose alias tag in domain RNG schema
Though <alias> is ignored when defining a domain, it can cause
failure if one validates (e.g. virt-xml-validate) the XML dumped
from a running domain. This patch expose it in domain RNG schema
for all the devices which support it.
2012-01-16 19:53:54 +08:00
Osier Yang
4447d2cbdf docs: Add readonly to filesystem RNG schema
"<readonly/>" is supported by filesystem XML, and also documented.
2012-01-16 19:53:44 +08:00
Michael Ellerman
8611d9c3d8 Make drive unit attribute optional in the XML schema
The "unit" attribute of a drive address is optional in the code, so should
also be in the XML schema.

Signed-off-by: Michael Ellerman <michael@ellerman.id.au>
2012-01-13 15:12:06 -07:00
Paolo Bonzini
c9abfadf37 qemu: add virtio-scsi controller model
Adding a new model for virtio-scsi roughly follows the same scheme
as the previous patch.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2012-01-13 14:54:48 -07:00
Paolo Bonzini
7b345b69f2 qemu: add ibmvscsi controller model
KVM will be able to use a PCI SCSI controller even on POWER.  Let
the user specify the vSCSI controller by other means than a default.

After this patch, the QEMU driver will actually look at the model
and reject anything but auto, lsilogic and ibmvscsi.

Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2012-01-13 14:13:30 -07:00
Osier Yang
5edfcaae6f qemu: Support copy on read for disk
The new introduced optional attribute "copy_on_read</code> controls
whether to copy read backing file into the image file. The value can
be either "on" or "off". Copy-on-read avoids accessing the same backing
file sectors repeatedly and is useful when the backing file is over a
slow network. By default copy-on-read is off.
2012-01-13 10:08:15 +08:00
Laine Stump
177db08775 qemu: add new disk device='lun' for bus='virtio' & type='block'
In the past, generic SCSI commands issued from a guest to a virtio
disk were always passed through to the underlying disk by qemu, and
the kernel would also pass them on.

As a result of CVE-2011-4127 (see:
http://seclists.org/oss-sec/2011/q4/536), qemu now honors its
scsi=on|off device option for virtio-blk-pci (which enables/disables
passthrough of generic SCSI commands), and the kernel will only allow
the commands for physical devices (not for partitions or logical
volumes). The default behavior of qemu is still to allow sending
generic SCSI commands to physical disks that are presented to a guest
as virtio-blk-pci devices, but libvirt prefers to disable those
commands in the standard virtio block devices, enabling it only when
specifically requested (hopefully indicating that the requester
understands what they're asking for). For this purpose, a new libvirt
disk device type (device='lun') has been created.

device='lun' is identical to the default device='disk', except that:

1) It is only allowed if bus='virtio', type='block', and the qemu
   version is "new enough" to support it ("new enough" == qemu 0.11 or
   better), otherwise the domain will fail to start and a
   CONFIG_UNSUPPORTED error will be logged).

2) The option "scsi=on" will be added to the -device arg to allow
   SG_IO commands (if device !='lun', "scsi=off" will be added to the
   -device arg so that SG_IO commands are specifically forbidden).

Guests which continue to use disk device='disk' (the default) will no
longer be able to use SG_IO commands on the disk; those that have
their disk device changed to device='lun' will still be able to use SG_IO
commands.

*docs/formatdomain.html.in - document the new device attribute value.
*docs/schemas/domaincommon.rng - allow it in the RNG
*tests/* - update the args of several existing tests to add scsi=off, and
 add one new test that will test scsi=on.
*src/conf/domain_conf.c - update domain XML parser and formatter

*src/qemu/qemu_(command|driver|hotplug).c - treat
 VIR_DOMAIN_DISK_DEVICE_LUN *almost* identically to
 VIR_DOMAIN_DISK_DEVICE_DISK, except as indicated above.

Note that no support for this new device value was added to any
hypervisor drivers other than qemu, because it's unclear what it might
mean (if anything) to those drivers.
2012-01-09 10:55:53 -05:00
Jiri Denemark
88ed9ec001 schemas: Allow '.' in CPU feature name
We already support CPU features with '.' in their name (e.g., sse4.1) so
we should not forbid that in the schema.
2012-01-04 13:29:43 +01:00
Eric Blake
6cb4acce8b seclabel: extend XML to allow per-disk label overrides
When doing security relabeling, there are cases where a per-file
override might be appropriate.  For example, with a static label
and relabeling, it might be appropriate to skip relabeling on a
particular disk, where the backing file lives on NFS that lacks
the ability to track labeling.  Or with dynamic labeling, it might
be appropriate to use a custom (non-dynamic) label for a disk
specifically intended to be shared across domains.

The new XML resembles the top-level <seclabel>, but with fewer
options (basically relabel='no', or <label>text</label>):

<domain ...>
  ...
  <devices>
    <disk type='file' device='disk'>
      <source file='/path/to/image1'>
        <seclabel relabel='no'/> <!-- override for just this disk -->
      </source>
      ...
    </disk>
    <disk type='file' device='disk'>
      <source file='/path/to/image1'>
        <seclabel relabel='yes'> <!-- override for just this disk -->
          <label>system_u:object_r:shared_content_t:s0</label>
        </seclabel>
      </source>
      ...
    </disk>
    ...
  </devices>
  <seclabel type='dynamic' model='selinux'>
    <baselabel>text</baselabel> <!-- used for all devices without override -->
  </seclabel>
</domain>

This patch only introduces the XML and documentation; future patches
will actually parse and make use of it.  The intent is that we can
further extend things as needed, adding a per-device <seclabel> in
more places (such as the source of a console device), and possibly
allowing a <baselabel> instead of <label> for labeling where we want
to reuse the cNNN,cNNN pair of a dynamically labeled domain but a
different base label.

First suggested by Daniel P. Berrange here:
https://www.redhat.com/archives/libvir-list/2011-December/msg00258.html

* docs/schemas/domaincommon.rng (devSeclabel): New define.
(disk): Use it.
* docs/formatdomain.html.in (elementsDisks, seclabel): Document
the new XML.
* tests/qemuxml2argvdata/qemuxml2argv-seclabel-dynamic-override.xml:
New test, to validate RNG.
2011-12-30 10:57:58 +08:00
Eric Blake
116d6af979 schema: rewrite seclabel rng to match code
The RNG for <seclabel> was too strict - if it was present, then it
had to have sub-elements, even if those didn't make sense for the
given attributes.  Also, we didn't have any tests of <seclabel>
parsing or XML output.

In this patch, I added more parsing tests than output tests (since
the output populates and/or reorders fields not present in certain
inputs).  Making the RNG reliable is a precursor to using <seclabel>
variants in more places in the XML in later patches.

See also:
http://berrange.com/posts/2011/09/29/two-small-improvements-to-svirt-guest-configuration-flexibility-with-kvmlibvirt/

* docs/schemas/domaincommon.rng (seclabel): Tighten rules.
* tests/qemuxml2argvtest.c (mymain): New tests.
* tests/qemuxml2xmltest.c (mymain): Likewise.
* tests/qemuxml2argvdata/qemuxml2argv-seclabel-*.*: New files.
2011-12-30 10:38:37 +08:00
Bharata B Rao
4ba56a9410 Add New address type spapr-vio to domain.rng
Original patch by Bharata. Updated to use {1,16} in spaprvioReg based
on example from Eric Blake.

Signed-off-by: Bharata B Rao <bharata@linux.vnet.ibm.com>
Signed-off-by: Prerna Saxena <prerna@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <michael@ellerman.id.au>
2011-12-20 16:01:25 -07:00
Eric Blake
dad3c2090d network: allow '-' in model name
In QEMU PPC64 we have a network device called "spapr-vlan". We can specify
this using the existing syntax for network devices, however libvirt
currently rejects "spapr-vlan" in virDomainNetDefParseXML() because of
the "-". Fix the code to accept "-".

* src/conf/domain_conf.c (virDomainNetDefParseXML): Allow '-' in
model name, and be more efficient.
* docs/schemas/domaincommon.rng: Limit valid model names to match code.
Based on a patch by Michael Ellerman.
2011-12-09 13:02:45 -07:00
Bharata B Rao
608786fc52 Add ppc64 specific definitions to domain.rng
ppc64 as new arch type and pseries as new machine type are
added under <os> ...  </os>.

Signed-off-by: Bharata B Rao <bharata@linux.vnet.ibm.com>
Signed-off-by: Prerna Saxena <prerna@linux.vnet.ibm.com>
2011-12-08 08:39:26 -05:00
Lei Li
6df7ccb10e Support block I/O throttle in XML
Enable block I/O throttle for per-disk in XML, as the first
per-disk IO tuning parameter.

Signed-off-by: Lei Li <lilei@linux.vnet.ibm.com>
Signed-off-by: Zhi Yong Wu <wuzhy@linux.vnet.ibm.com>
Signed-off-by: Eric Blake <eblake@redhat.com>
2011-11-30 11:36:09 -07:00
Hu Tao
6ac81c8ec8 blkiotune: add interface for blkiotune.device_weight
This adds per-device weights to <blkiotune>.  Note that the
cgroups implementation only supports weights per block device,
and not per-file within the device; hence this option must be
global to the domain definition rather than tied to individual
<devices>/<disk> entries:

<domain ...>
  <blkiotune>
    <device>
      <path>/path/to/block</path>
      <weight>1000</weight>
    </device>
  </blkiotune>
..

This patch also adds a parameter --device-weights to virsh command
blkiotune for setting/getting blkiotune.weight_device for any
hypervisor that supports it.  All <device> entries under
<blkiotune> are concatenated into a single string attribute under
virDomain{Get,Set}BlkioParameters, named "device_weight".

Signed-off-by: Hu Tao <hutao@cn.fujitsu.com>
Signed-off-by: Eric Blake <eblake@redhat.com>
2011-11-29 12:26:21 -07:00
Lorin Hochstein
8078a90a24 conf: make virt-xml-validate work with vbox domains
virt-xml-validate fails when run on a domain XML file of type 'vbox'.

For failing test case, see https://bugzilla.redhat.com/show_bug.cgi?id=757097

This patch updates the XML schema to accept all valid hypervisor
types, as well as dropping hypervisor types that are not in use
by the current code base.

Signed-off-by: Eric Blake <eblake@redhat.com>
2011-11-28 09:16:07 -07:00
Bharata B Rao
5f7b71b413 XML definitions for guest NUMA and parsing routines
This patch adds XML definitions for guest NUMA specification and contains
routines to parse the same. The guest NUMA specification looks like this:

<cpu>
        ...
        <topology sockets='2' cores='4' threads='2'/>
        <numa>
                <cell cpus='0-7' memory='512000'/>
                <cell cpus='8-15' memory='512000'/>
        </numa>
        ...
</cpu>

Signed-off-by: Bharata B Rao <bharata@linux.vnet.ibm.com>
2011-11-17 13:34:42 -07:00
Josh Durgin
7e02076624 Use a common xml type for ceph secret usage.
The types used in domaincommon.rng and secret.rng should be the same.

Move genericName to basictypes.rng, then drop redundant types now
that secret.rng uses basictypes.rng.

Signed-off-by: Josh Durgin <josh.durgin@dreamhost.com>
Signed-off-by: Eric Blake <eblake@redhat.com>
2011-10-28 16:01:14 -06:00
Josh Durgin
5bd6271f59 storage: add auth to virDomainDiskDef
Add additional fields to let you specify the how to authenticate with a disk.
The secret to use may be referenced by a usage string or a UUID, i.e.:

<auth username='myuser'>
 <secret type='ceph' usage='secretname'/>
</auth>

or

<auth username='myuser'>
 <secret type='ceph' uuid='0a81f5b2-8403-7b23-c8d6-21ccc2f80d6f'/>
</auth>

Signed-off-by: Josh Durgin <josh.durgin@dreamhost.com>
2011-10-28 12:51:22 -06:00
Michal Privoznik
e5a84d74a2 conf: Introduce optional startupPolicy attribute for cdrom and floppy
This attribute says what to do with cdrom (or floppy) if
the source is missing. It accepts:
- mandatory - fail if missing for any reason (the default)
- requisite - fail if missing on boot up, drop if missing on
              migrate/restore/revert
- optional  - drop if missing at any start attempt.

However, this patch introduces only XML part of this new
functionality.
2011-10-25 09:22:42 +02:00
Jim Fehlig
c1bc3d892c Add AHCI support to qemu driver
Tested with multiple AHCI controllers and multiple disks attached
to a controller. E.g.,

    <disk type='file' device='disk'>
      <driver name='qemu' type='raw'/>
      <source file='/var/lib/libvirt/images/test/disk0.raw'/>
      <target dev='sda' bus='sata'/>
      <address type='drive' controller='0' bus='0' unit='0'/>
    </disk>
    <disk type='file' device='disk'>
      <driver name='qemu' type='raw'/>
      <source file='/var/lib/libvirt/images/test/disk1.raw'/>
      <target dev='sdb' bus='sata'/>
      <address type='drive' controller='0' bus='0' unit='1'/>
    </disk>
    <disk type='file' device='disk'>
      <driver name='qemu' type='raw'/>
      <source file='/var/lib/libvirt/images/test/disk2.raw'/>
      <target dev='sdc' bus='sata'/>
      <address type='drive' controller='1' bus='0' unit='0'/>
    </disk>
    <controller type='sata' index='0'>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/>
    </controller>
    <controller type='sata' index='1'>
      <address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/>
    </controller>
2011-10-17 15:44:21 -06:00
Harsh Prateek Bora
da8127e6b3 Introduce <driver> under <filesystem> to support open-by-handle
VirtFS allows the user to choose between path/handle based fs driver.
As of now, libvirt hardcoded path based driver only. This patch provides
a solution to allow user to choose between path/handle based fs driver.

Sample:

    <filesystem type='mount'>
      <driver type='handle'/>
      <source dir='/folder/to/share1'/>
      <target dir='mount_tag1'/>
    </filesystem>

    <filesystem type='mount'>
      <driver type='path'/>
      <source dir='/folder/to/share2'/>
      <target dir='mount_tag2'/>
    </filesystem>

Signed-off-by: Harsh Prateek Bora <harsh@linux.vnet.ibm.com>
Signed-off-by: Eric Blake <eblake@redhat.com>
2011-10-12 12:15:28 -06:00
Laine Stump
4bb4109f7b qemu: add separate rerror_policy for disk errors
Previously libvirt's disk device XML only had a single attribute,
error_policy, to control both read and write error policy, but qemu
has separate options for controlling read and write. In one case
(enospc) a policy is allowed for write errors but not read errors.

This patch adds a separate attribute that sets only the read error
policy. If just error_policy is set, it will apply to both read and
write error policy (previous behavior), but if the new rerror_policy
attribute is set, it will override error_policy for read errors only.
Possible values for rerror_policy are "stop", "report", and "ignore"
("report" is the qemu-controlled default for rerror_policy when
error_policy isn't specified).

For consistency, the value "report" has been added to the possible
values for error_policy as well.
2011-10-06 14:49:23 -04:00
Laine Stump
c329db7180 qemu: make PCI multifunction support more manual
When support for was added for PCI multifunction cards (in commit
9f8baf, first included in libvirt 0.9.3), it was done by always
turning on the multifunction bit for all PCI devices. Since that time
it has been realized that this is not an ideal solution, and that the
multifunction bit must be selectively turned on. For example, see

  https://bugzilla.redhat.com/show_bug.cgi?id=728174

and the discussion before and after

  https://www.redhat.com/archives/libvir-list/2011-September/msg01036.html

This patch modifies multifunction support so that the multifunction=on
option is only added to the qemu commandline for a device if its PCI
<address> definition has the attribute "multifunction='on'", e.g.:

  <address type='pci' domain='0x0000' bus='0x00'
           slot='0x04' function='0x0' multifunction='on'/>

In practice, the multifunction bit should only be turned on if
function='0' AND other functions will be used in the same slot - it
usually isn't needed for functions 1-7 (although there are apparently
some exceptions, e.g. the Intel X53 according to the QEMU source
code), and should never be set if only function 0 will be used in the
slot. The test cases have been changed accordingly to illustrate.

With this patch in place, if a user attempts to assign multiple
functions in a slot without setting the multifunction bit for function
0, libvirt will issue an error when the domain is defined, and the
define operation will fail. In the future, we may decide to detect
this situation and automatically add multifunction=on to avoid the
error; even then it will still be useful to have a manual method of
turning on multifunction since, as stated above, there are some
devices that excpect it to be turned on for all functions in a slot.

A side effect of this patch is that attempts to use the same PCI
address for two different devices will now log an error (previously
this would cause the domain define operation to fail, but there would
be no log message generated). Because the function doing this log was
almost completely rewritten, I didn't think it worthwhile to make a
separate patch for that fix (the entire patch would immediately be
obsoleted).
2011-10-01 11:48:28 -04:00
Laine Stump
dc79852af8 qemu: add ability to set PCI device "rombar" on or off
This patch was made in response to:

  https://bugzilla.redhat.com/show_bug.cgi?id=738095

In short, qemu's default for the rombar setting (which makes the
firmware ROM of a PCI device visible/not on the guest) was previously
0 (not visible), but they recently changed the default to 1
(visible). Unfortunately, there are some PCI devices that fail in the
guest when rombar is 1, so the setting must be exposed in libvirt to
prevent a regression in behavior (it will still require explicitly
setting <rom bar='off'/> in the guest XML).

rombar is forced on/off by adding:

  <rom bar='on|off'/>

inside a <hostdev> element that defines a PCI device. It is currently
ignored for all other types of devices.

At the moment there is no clean method to determine whether or not the
rombar option is supported by QEMU - this patch uses the advice of a
QEMU developer to assume support for qemu-0.12+. There is currently a
patch in the works to put this information in the output of "qemu-kvm
-device pci-assign,?", but of course if we switch to keying off that,
we would lose support for setting rombar on all the versions of qemu
between 0.12 and whatever version gets that patch.
2011-09-27 11:23:28 -04:00
Oskari Saarenmaa
f887334dcf Add unsafe cache mode support for disk driver
QEMU 0.13 introduced cache=unsafe for -drive, this patch exposes
it in the libvirt layer.

  * Introduced a new QEMU capability flag ($prefix_CACHE_UNSAFE),
    as even if $prefix_CACHE_V2 is set, we can't know if unsafe
    is supported.

  * Improved the reliability of qemu cache type detection.
2011-09-23 08:29:57 -06:00
Marc-André Lureau
2e0dbaad9b redirdev: allows to specify device address
It is important to be able to attach USB redirected devices to a
particular controller (one that supports USB2 for instance).
Without this patch, only the default bus was used.

     <redirdev bus='usb' type='spicevmc'>
       <address type='usb' bus='0' port='4'/>
     </redirdev>
2011-09-06 15:12:52 +08:00
Eric Blake
89b6284fd9 snapshot: also support disks by path
I got confused when 'virsh domblkinfo dom disk' required the
path to a disk (which can be ambiguous, since a single file
can back multiple disks), rather than the unambiguous target
device name that I was using in disk snapshots.  So, in true
developer fashion, I went for the best of both worlds - all
interfaces that operate on a disk (aka block) now accept
either the target name or the unambiguous path to the backing
file used by the disk.

* src/conf/domain_conf.h (virDomainDiskIndexByName): Add
parameter.
(virDomainDiskPathByName): New prototype.
* src/libvirt_private.syms (domain_conf.h): Export it.
* src/conf/domain_conf.c (virDomainDiskIndexByName): Also allow
searching by path, and decide whether ambiguity is okay.
(virDomainDiskPathByName): New function.
(virDomainDiskRemoveByName, virDomainSnapshotAlignDisks): Update
callers.
* src/qemu/qemu_driver.c (qemudDomainBlockPeek)
(qemuDomainAttachDeviceConfig, qemuDomainUpdateDeviceConfig)
(qemuDomainGetBlockInfo, qemuDiskPathToAlias): Likewise.
* src/qemu/qemu_process.c (qemuProcessFindDomainDiskByPath):
Likewise.
* src/libxl/libxl_driver.c (libxlDomainAttachDeviceDiskLive)
(libxlDomainDetachDeviceDiskLive, libxlDomainAttachDeviceConfig)
(libxlDomainUpdateDeviceConfig): Likewise.
* src/uml/uml_driver.c (umlDomainBlockPeek): Likewise.
* src/xen/xend_internal.c (xenDaemonDomainBlockPeek): Likewise.
* docs/formatsnapshot.html.in: Update documentation.
* tools/virsh.pod (domblkstat, domblkinfo): Likewise.
* docs/schemas/domaincommon.rng (diskTarget): Tighten pattern on
disk targets.
* docs/schemas/domainsnapshot.rng (disksnapshot): Update to match.
* tests/domainsnapshotxml2xmlin/disk_snapshot.xml: Update test.
2011-09-05 07:03:04 -06:00
Eric Blake
471235307f snapshot: additions to domain xml for disks
As discussed here:
https://www.redhat.com/archives/libvir-list/2011-August/msg00361.html
https://www.redhat.com/archives/libvir-list/2011-August/msg00552.html

Adds snapshot attribute and transient sub-element:

<devices>
  <disk type=... snapshot='no|internal|external'>
    ...
    <transient/>
  </disk>
</devices>

* docs/schemas/domaincommon.rng (snapshot): New define.
(disk): Add snapshot and persistent attributes.
* docs/formatdomain.html.in: Document them.
* src/conf/domain_conf.h (virDomainDiskSnapshot): New enum.
(_virDomainDiskDef): New fields.
* tests/qemuxml2argvdata/qemuxml2argv-disk-transient.xml: New
test of rng, no args counterpart until qemu support is complete.
* tests/qemuxml2argvdata/qemuxml2argv-disk-snapshot.args: New
file, snapshot attribute does not affect args.
* tests/qemuxml2argvdata/qemuxml2argv-disk-snapshot.xml: Likewise.
* tests/qemuxml2argvtest.c (mymain): Run new test.
2011-09-05 07:03:04 -06:00
Eric Blake
2a95a3e976 snapshot: update rng to support full domain in xml
This patch will probably cause merge conflicts to those trying
to do backports.  The end goal is simple - domaincommon.rng
should be the state of domain.rng pre-patch, with a few lines
tweaked in the header, while domain.rng post-patch is now just
a shell that includes domaincommon.rng and sets the <start>.

* docs/schemas/domain.rng: Move guts...
* docs/schemas/domaincommon.rng: ...to new file.
* docs/schemas/domainsnapshot.rng: Allow new xml.
* docs/schemas/Makefile.am (schema_DATA): Distribute new file.
* tests/domainsnapshotxml2xmlout/full_domain.xml: New test.
* libvirt.spec.in (%files client): Ship new file.  Sort lines.
* mingw32-libvirt.spec.in: Likewise.
2011-09-03 08:12:13 -06:00