When using logical pools, we had to trust the target->path provided.
This parameter, however, can be completely ommited and we can use
'/dev/<source.name>' safely and populate it to target.path.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=952973
The existing 'chap' XML logic was never used - just defined. Rather than
try to insert a square peg into a round hole, blow it up and rewrite the
logic to follow the 'ceph' format.
Remove the former "chap.login" and "chap.passwd" fields and replace
with "chap.username" and "chap.secret" in _virStoragePoolAuthChap.
Adjust the virStoragePoolDefParseAuthChap() to process.
Change the rng file to describe the new layout
Update the formatstorage.html to describe the usage of the secret element
to mention that the secret type "iscsi" and "ceph" can be used
to storage pool too.
Update the formatsecret.html to include a reference to the storage pool
Update tests to handle the changes from 'login' and 'passwd' to 'username'
and '<secret>' format
This introduces 4 new attributes for storage pool source adapter.
E.g.
<adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>
Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
for 'scsi_host' adapter, for back-compat reason. However, mandatory
for 'fc_host' adapter and any new future adapter types. Attribute
'parent' is to specify the parent for the fc_host adapter.
* docs/formatstorage.html.in:
- Add documents for the 4 new attrs
* docs/schemas/storagepool.rng:
- Add RNG schema
* src/conf/storage_conf.c:
- Parse and format the new XMLs
* src/conf/storage_conf.h:
- New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
- New enum virStoragePoolSourceAdapterType
* src/libvirt_private.syms:
- Export TypeToString and TypeFromString
* src/phyp/phyp_driver.c:
- Replace "adapter" with "adapter.data.name", which is member of the union
of the new struct virStoragePoolSourceAdapter now. Later patch will
add the checking, as "adapter.data.name" is only valid for "scsi_host"
adapter.
* src/storage/storage_backend_scsi.c:
- Like above
* tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
- New test for 'fc_host' and "scsi_host" adapter
* tests/storagepoolxml2xmlout/pool-scsi.xml:
- Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
specified now
* tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
- New test
* tests/storagepoolxml2xmltest.c:
- Include the test
capability.rng: Guest features can be in any order.
nodedev.rng: Added <driver> element, <capability> phys_function and
virt_functions for PCI devices.
storagepool.rng: Owner or group ID can be -1.
schema tests: New capabilities and nodedev files; changed owner and
group to -1 in pool-dir.xml.
storage_conf: Print uid_t and gid_t as signed to storage pool XML.
This patch brings support to manage sheepdog pools and volumes to libvirt.
It uses the "collie" command-line utility that comes with sheepdog for that.
A sheepdog pool in libvirt maps to a sheepdog cluster.
It needs a host and port to connect to, which in most cases
is just going to be the default of localhost on port 7000.
A sheepdog volume in libvirt maps to a sheepdog vdi.
To create one specify the pool, a name and the capacity.
Volumes can also be resized later.
In the volume XML the vdi name has to be put into the <target><path>.
To use the volume as a disk source for virtual machines specify
the vdi name as "name" attribute of the <source>.
The host and port information from the pool are specified inside the host tag.
<disk type='network'>
...
<source protocol="sheepdog" name="vdi_name">
<host name="localhost" port="7000"/>
</source>
</disk>
To work right this patch parses the output of collie,
so it relies on the raw output option. There recently was a bug which caused
size information to be reported wrong. This is fixed upstream already and
will be in the next release.
Signed-off-by: Sebastian Wiedenroth <wiedi@frubar.net>
This patch adds support for a new storage backend with RBD support.
RBD is the RADOS Block Device and is part of the Ceph distributed storage
system.
It comes in two flavours: Qemu-RBD and Kernel RBD, this storage backend only
supports Qemu-RBD, thus limiting the use of this storage driver to Qemu only.
To function this backend relies on librbd and librados being present on the
local system.
The backend also supports Cephx authentication for safe authentication with
the Ceph cluster.
For storing credentials it uses the built-in secret mechanism of libvirt.
Signed-off-by: Wido den Hollander <wido@widodh.nl>
I wrote a patch to add support for listing the Vendor and Model of a
storage pool in the storage pool XML. This would allow vendor
extensions of specific devices. The patch includes a test for the new
attributes as well.
Patrick Dignan
Spurious / in a pool target path makes life difficult for apps using the
GetVolByPath, and doing other path based comparisons with pools. This
has caused a few issues for virt-manager users:
https://bugzilla.redhat.com/show_bug.cgi?id=494005https://bugzilla.redhat.com/show_bug.cgi?id=593565
Add a new util API which removes spurious /, virFileSanitizePath. Sanitize
target paths when parsing pool XML, and for paths passed to GetVolByPath.
v2: Leading // must be preserved, properly sanitize path=/, sanitize
away /./ -> /
v3: Properly handle starting ./ and ending /.
v4: Drop all '.' handling, just sanitize / for now.