Jim Fehlig
b494e09d05 docs: schema: make disk driver name attribute optional
/domain/devices/disk/driver/@name is not a required or mandatory
attribute according to formatdomain, and indeed it was agreed on
IRC that the attribute is "optional for input, recommended (but
not required) for output". Currently the schema requires the
attribute, causing virt-xml-validate to fail on disk config where
the driver name is not explicitly specified. E.g.

# cat test.xml | grep -A 5 cdrom
    <disk type='file' device='cdrom'>
      <driver type='raw'/>
      <target dev='hdb' bus='ide'/>
      <readonly/>
      <address type='drive' controller='0' bus='0' target='0' unit='1'/>
    </disk>

# virt-xml-validate test.xml
Relax-NG validity error : Extra element devices in interleave
test.xml:21: element devices: Relax-NG validity error : Element domain failed to validate content
test.xml fails to validate

Relaxing the name attribute to be optional fixes the validation

# virt-xml-validate test.xml
test.xml validates
2017-07-18 11:39:52 -06:00
Andrea Bolognani
47dd6e282a conf: Parse and format <target index='...'/>
Signed-off-by: Andrea Bolognani <abologna@redhat.com>
Reviewed-by: Laine Stump <laine@laine.org>
2017-07-15 14:50:42 +02:00
Andrea Bolognani
90855eca3f conf: Add 'spapr-pci-host-bridge' controller model
Adding it to the virDomainControllerPCIModelName enumeration
is enough for existing code to handle it, so parsing and
formatting will work without further tweaking.

Signed-off-by: Andrea Bolognani <abologna@redhat.com>
Reviewed-by: Laine Stump <laine@laine.org>
2017-07-15 14:50:42 +02:00
Cédric Bosdonnat
426929aea9 lxc: add possibility to define init uid/gid
Users may want to run the init command of a container as a special
user / group. This is achieved by adding <inituser> and <initgroup>
elements. Note that the user can either provide a name or an ID to
specify the user / group to be used.

This commit also fixes a side effect of being able to run the command
as a non-root user: the user needs rights on the tty to allow shell
job control.

Reviewed-by: Daniel P. Berrange <berrange@redhat.com>
2017-07-11 10:41:24 +02:00
Cédric Bosdonnat
552f7c139a lxc: allow user to specify command working directory
Some containers may want the application to run in a special directory.
Add <initdir> element in the domain configuration to handle this case
and use it in the lxc driver.

Reviewed-by: Daniel P. Berrange <berrange@redhat.com>
2017-07-11 10:41:24 +02:00
Cédric Bosdonnat
25630a3735 lxc: allow defining environment variables
When running an application container, setting environment variables
could be important.

The newly introduced <initenv> tag in domain configuration will allow
setting environment variables to the init program.

Reviewed-by: Daniel P. Berrange <berrange@redhat.com>
2017-07-11 10:41:23 +02:00
Roman Bogorodskiy
78fc843c7b bhyve: add vga configuration for video driver
Add support for vgaconf driver configuration. In domain xml it looks like
this:

  <video>
    <driver vgaconf='io|on|off'>
    <model .../>
  </video>

It was added with bhyve gop video in mind to allow users control how the
video device is exposed to the guest, specifically, how VGA I/O is
handled.

One can refer to the bhyve manual page to get more detailed description
of the possible VGA configuration options:

https://www.freebsd.org/cgi/man.cgi?query=bhyve&manpath=FreeBSD+12-current

The relevant part could be found using the 'vgaconf' keyword.

Also, add some tests for this new feature.

Signed-off-by: Roman Bogorodskiy <bogorodskiy@gmail.com>
Reviewed-by: John Ferlan <jferlan@redhat.com>
2017-06-27 17:44:27 +04:00
Farhan Ali
54fa1b44af conf: Add loadparm boot option for a boot device
Update the per device boot schema to add an optional loadparm parameter.

eg: <boot order='1' loadparm='2'/>

Extend the virDomainDeviceInfo to support loadparm option.
Modify the appropriate functions to parse loadparm from boot device xml.
Add the xml2xml test to validate the field.

Signed-off-by: Farhan Ali <alifm@linux.vnet.ibm.com>
Reviewed-by: Bjoern Walk <bwalk@linux.vnet.ibm.com>
Reviewed-by: Boris Fiuczynski <fiuczy@linux.vnet.ibm.com>
Reviewed-by: Marc Hartmayer <mhartmay@linux.vnet.ibm.com>
2017-06-20 07:03:22 -04:00
Martin Kletzander
cc9f0521cd Report more correct information for cache control
On some platforms the number of bits in the cbm_mask might not be
divisible by 4 (and not even by 2), so we need to properly count the
bits.  Similar file, min_cbm_bits, is properly parsed and used, but if
the number is greater than one, we lose the information about
granularity when reporting the data in capabilities.  For that matter
always report granularity, but if it is not the same as the minimum,
add that information in there as well.

Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
2017-06-16 13:09:41 +02:00
Ján Tomko
cc0933d350 Add virtio-related options to input devices
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:53 +02:00
Ján Tomko
f5384fb402 Add virtio-related options to video
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:49 +02:00
Ján Tomko
f65db1be12 Add virtio-related options to rng devices
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:44 +02:00
Ján Tomko
b10c22d9fa Add virtio-related options to filesystems
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:40 +02:00
Ján Tomko
c85217cf8a Add virtio-related options to controllers
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:33 +02:00
Ján Tomko
1bc2cb3b32 Add virtio-related options to disks
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:27 +02:00
Ján Tomko
82223f9364 add virtio-related options to memballoon
https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:32:11 +02:00
Ján Tomko
fd51864340 Add virtio-related options to interfaces
<interface type='user'>
  <mac address='52:54:56:5a:5c:5e'/>
  <model type='virtio'/>
  <driver iommu='on' ats='on'/>
</interface>

https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:31:54 +02:00
Ján Tomko
27b187be39 conf: add iotlb attribute to iommu
Add a new iotlb attribute to the iommu device
to control the device IOTLB support for intel-iommu.

https://bugzilla.redhat.com/show_bug.cgi?id=1283251

Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-08 16:31:09 +02:00
Jiri Denemark
5c2f01abcb qemu: Store save cookie in save images and snapshots
The following patches will add an actual content in the cookie and use
the data when restoring a domain.

Signed-off-by: Jiri Denemark <jdenemar@redhat.com>
Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
2017-06-07 13:36:02 +02:00
Eli Qiao
0ab409ccc4 Expose resource control capabilities for caches
Add cache resource control into capabilities for CAT without CDP:

  <cache>
    <bank id='0' level='3' type='unified' size='15360' unit='KiB' cpus='0-5'>
      <control min='768' unit='KiB' scope='both' max_allocation='4'/>
    </bank>
  </cache>

and with CDP:

  <cache>
    <bank id='0' level='3' type='unified' size='15360' unit='KiB' cpus='0-5'>
      <control min='768' unit='KiB' scope='code' max_allocation='4'/>
      <control min='768' unit='KiB' scope='data' max_allocation='4'/>
    </bank>
  </cache>

Also add new test cases for vircaps2xmltest.

Signed-off-by: Eli Qiao <liyong.qiao@intel.com>
2017-06-05 09:50:51 +02:00
Bjoern Walk
bb2adfe934 node_device: introduce new capability FC_RPORT
Similar to scsi_host and fc_host, there is a relation between a
scsi_target and its transport specific fc_remote_port. Let's expose this
relation and relevant information behind it.

An example for a virsh nodedev-dumpxml:

    virsh # nodedev-dumpxml scsi_target0_0_0
    <device>
      <name>scsi_target0_0_0</name>
      <path>/sys/devices/[...]/host0/rport-0:0-0/target0:0:0</path>
      <parent>scsi_host0</parent>
      <capability type='scsi_target'>
        <target>target0:0:0</target>
        <capability type='fc_remote_port'>
          <rport>rport-0:0-0</rport>
          <wwpn>0x9d73bc45f0e21a86</wwpn>
        </capability>
      </capability>
    </device>

Reviewed-by: Boris Fiuczynski <fiuczy@linux.vnet.ibm.com>
Signed-off-by: Bjoern Walk <bwalk@linux.vnet.ibm.com>
2017-05-26 10:44:05 -04:00
Bjoern Walk
b0ffd938d4 node_device: detect CCW devices
Make CCW devices available to the node_device driver. The devices are
already seen by udev so let's implement necessary code for detecting
them properly.

Topologically, CCW devices are similar to PCI devices, e.g.:

    +- ccw_0_0_1a2b
        |
        +- scsi_host0
            |
            +- scsi_target0_0_0
                |
                +- scsi_0_0_0_0

Reviewed-by: Boris Fiuczynski <fiuczy@linux.vnet.ibm.com>
Signed-off-by: Bjoern Walk <bwalk@linux.vnet.ibm.com>
2017-05-26 10:44:05 -04:00
Ján Tomko
dc61d92758 conf: add eim attribute to <iommu><driver>
Add an attribute to control extended interrupt mode.

https://bugzilla.redhat.com/show_bug.cgi?id=1451282

Reviewed-by: Andrea Bolognani <abologna@redhat.com>
2017-05-26 08:11:25 +02:00
Erik Skultety
88ef73e13c nodedev: Introduce mdev capability for mediated devices
Start discovering the mediated devices on the host system and format the
attributes for the mediated device into the XML. Compared to the parent
device which reports generic information about the abstract mediated
devices types, a child device only reports the type name it has been
instantiated from and the IOMMU group number, since that's device
specific compared to the rest of the info that can be gathered about
mediated devices at the moment.
This patch introduces both the formatting and parsing routines, updates
nodedev.rng schema, adding a testcase as well.

The resulting mdev child device XML:
<device>
  <name>mdev_4b20d080_1b54_4048_85b3_a6a62d165c01</name>
  <path>/sys/devices/.../4b20d080-1b54-4048-85b3-a6a62d165c01</path>
  <parent>pci_0000_06_00_0</parent>
  <driver>
    <name>vfio_mdev</name>
  </driver>
  <capability type='mdev'>
    <type id='vendor_supplied_type_id'/>
    <iommuGroup number='NUM'/>
  <capability/>
<device/>

https://bugzilla.redhat.com/show_bug.cgi?id=1452072

Signed-off-by: Erik Skultety <eskultet@redhat.com>
2017-05-18 12:21:45 +02:00
Erik Skultety
500cbc066a nodedev: Introduce the mdev capability to a PCI parent device
The parent device needs to report the generic stuff about the supported
mediated devices types, like device API, available instances, type name,
etc. Therefore this patch introduces a new nested capability element of
type 'mdev_types' with the resulting XML of the following format:

<device>
  ...
  <capability type='pci'>
    ...
    <capability type='mdev_types'>
      <type id='vendor_supplied_id'>
        <name>optional_vendor_supplied_codename</name>
        <deviceAPI>vfio-pci</deviceAPI>
        <availableInstances>NUM</availableInstances>
      </type>
        ...
      <type>
        ...
      </type>
    </capability>
  </capability>
  ...
</device>

https://bugzilla.redhat.com/show_bug.cgi?id=1452072

Signed-off-by: Erik Skultety <eskultet@redhat.com>
2017-05-18 12:21:33 +02:00
Ján Tomko
d12781b47e conf: add caching_mode attribute to iommu device
Add a new attribute to control the caching mode.

https://bugzilla.redhat.com/show_bug.cgi?id=1427005
2017-05-15 15:44:11 +02:00
Ján Tomko
2020e2c6f2 conf: add <driver intremap> to <iommu>
Add a new attribute to control interrupt remapping.

https://bugzilla.redhat.com/show_bug.cgi?id=1427005
2017-05-15 15:44:11 +02:00
Ján Tomko
8023b21a95 conf: add <ioapic driver> to <features>
Add a new <ioapic> element with a driver attribute.

Possible values are qemu and kvm. With 'qemu', the I/O
APIC can be put in the userspace even for KVM domains.

https://bugzilla.redhat.com/show_bug.cgi?id=1427005
2017-05-15 15:41:17 +02:00
Martin Kletzander
4ad6a73bfc Add host cache information in capabilities
We're only adding only info about L3 caches, we can add more
later (just by changing one line), but for now that's more than enough
without overwhelming anyone.

XML snippet of how this should look like (also seen as part of the commit):

  <cache>
    <bank id='0' level='3' type='both' size='8192' unit='KiB' cpus='0-7'/>
  </cache>

Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
2017-05-09 13:12:40 +02:00
Pavel Hrdina
278e70f8f8 qemu: add support for qemu-xhci USB controller
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1438682

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
Acked-by: Andrea Bolognani <abologna@redhat.com>
2017-04-28 10:44:36 +02:00
Peter Krempa
d2e6bef305 docs: schemas: Split up definitions for NBD and gluster
NBD does not mandate a "filename". Gluster can have more servers. Split
them so that we can tighten the schema.
2017-04-28 10:22:22 +02:00
Peter Krempa
3240b8324c docs: schemas: Split out simple network protocols
ftp/tftp/sheepdog have a mandatory filename and support only one host.
There are no additional options for them.
2017-04-28 09:48:26 +02:00
Peter Krempa
bde5c2f532 docs: schemas: Extract HTTP disk source specification
Make the schema more strict for HTTP disks requiring a name and
mandating exactly one source host.

ftp/tftp entries were not moved here, since http transport also will
support cookies and other options, which will be added later.
2017-04-28 09:48:26 +02:00
Peter Krempa
9030fab20c docs: schemas: Extract RBD-specific data
RBD driver supports specifying a snapshot image name or config file.
Create a define for RBD and move the specifics there.
2017-04-28 09:48:26 +02:00
Peter Krempa
1779e378f8 docs: schemas: Move the interleave definition into network disk source
Move it to the place where actually interleaving elements can be placed.
2017-04-28 09:48:26 +02:00
Peter Krempa
47b947a0a3 docs: schemas: Extract disk source host specification
'diskSourceNetwork' schema define was rather big and it would be hard to
simplify it. Split out the host portion subelement into a separate
define.
2017-04-28 09:48:26 +02:00
Peter Krempa
8a99095cc6 docs: schemas: Remove <interleave> from file/block/dir/volume disks
They don't contain any elements to interleave.
2017-04-28 09:48:26 +02:00
Jiri Denemark
a646a6016a Add support for CPU cache specification
This patch introduces

    <cache level='N' mode='emulate'/>
    <cache mode='passthrough'/>
    <cache mode='disable'/>

sub element of /domain/cpu. Currently only a single <cache> element is
allowed.

Signed-off-by: Jiri Denemark <jdenemar@redhat.com>
2017-04-27 22:07:14 +02:00
Martin Kletzander
523c996062 conf, docs: Add support for coalesce setting(s)
We are currently parsing only rx/frames/max because that's the only
value that makes sense for us.  The tun device just added support for
this one and the others are only supported by hardware devices which
we don't need to worry about as the only way we'd pass those to the
domain is using <hostdev/> or <interface type='hostdev'/>.  And in
those cases the guest can modify the settings itself.

Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
2017-04-21 13:34:41 +02:00
Peter Krempa
8e0139869a docs: Move news.rng out of docs/schemas
docs/schemas directory is meant for schemas which are installed on the
system. The schema for the news file does not need to be installed.
Store it along with the file it describes for simplicity.
2017-04-05 09:51:51 +02:00
Ján Tomko
3af6c37816 news.rng: work around a bug in old libxml2
Similar to commit c3c2cc6, use a literal newsline instead of \n
inside the brackets.
2017-04-04 08:56:26 +02:00
Andrea Bolognani
a26603f684 news: Allow empty <section> elements
Creating dummy <change> elements was a workaround for the
HTML DTD not allowing empty <ul> elements, but we can do
better by tweaking the the XSLT stylesheet.
2017-04-03 10:49:42 +02:00
Peter Krempa
fe26b28564 schema: Introduce schema for the news.xml file
Since this file gets changed (and broken) rather often, introduce a
schema file so that the test suite can validate it.
2017-04-03 08:42:09 +02:00
Ján Tomko
8ef12b96fa schema: do not require name for certain pool types
Pool types that have the VIR_STORAGE_POOL_SOURCE_NAME flag set
allow omitting the <name> element and instead fill out the pool name
from the <source><name> element.

Relax the schema to make <name> optional for these pools.
Expressing that at least one of these is required is out of scope
of the schema.
2017-03-29 10:36:55 +02:00
Laine Stump
b101101d09 docs: make interface start mode element optional
This brings the libvirt version of this RNG file in line with the same
file in netcf (as soon as the corresponding patch there is ACKed and
pushed).

There's no reason to require it when defining an interface (the config
option it corresponds to is optional), and it isn't even output in the
status of an interface.

Resolves: https://bugzilla.redhat.com/1414404
2017-03-27 10:22:15 -04:00
Erik Skultety
ec783d7c77 conf: Introduce new hostdev device type mdev
A mediated device will be identified by a UUID (with 'model' now being
a mandatory <hostdev> attribute to represent the mediated device API) of
the user pre-created mediated device. We also need to make sure that if
user explicitly provides a guest address for a mdev device, the address
type will be matching the device API supported on that specific mediated
device and error out with an incorrect XML message.

The resulting device XML:
<devices>
  <hostdev mode='subsystem' type='mdev' model='vfio-pci'>
    <source>
      <address uuid='c2177883-f1bb-47f0-914d-32a22e3a8804'>
    </source>
  </hostdev>
</devices>

Signed-off-by: Erik Skultety <eskultet@redhat.com>
2017-03-27 15:39:35 +02:00
Roman Bogorodskiy
c27aa64786 schema: domaincaps: make machine element optional
Commit df769041c made the 'machine' element in domaincaps
optional. Update the schema to reflect that.
2017-03-26 18:35:14 +04:00
Jiri Denemark
641b8c721e Introduce /domain/cpu/@check XML attribute
The attribute can be used to request a specific way of checking whether
the virtual CPU matches created by the hypervisor matches the
specification in domain XML.

Signed-off-by: Jiri Denemark <jdenemar@redhat.com>
2017-03-17 11:50:48 +01:00
Andrea Bolognani
c51090fc99 qemu: Add support for generic PCIe Root Ports
QEMU 2.9 introduces the pcie-root-port device, which is
a generic version of the existing ioh3420 device.

Make the new device available to libvirt users.
2017-03-17 10:06:11 +01:00
Michal Privoznik
e433546bef qemu: Introduce label-size for NVDIMMs
For NVDIMM devices it is optionally possible to specify the size
of internal storage for namespaces. Namespaces are a feature that
allows users to partition the NVDIMM for different uses.

Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
2017-03-15 14:39:22 +01:00