Commit Graph

9 Commits

Author SHA1 Message Date
Osier Yang
622aaa0ac2 Storage: Fix the indention of rbd test file 2013-06-03 11:20:01 +08:00
Osier Yang
9f781da69d New XML attributes for storage pool source adapter
This introduces 4 new attributes for storage pool source adapter.
E.g.

<adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>

Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
for 'scsi_host' adapter, for back-compat reason. However, mandatory
for 'fc_host' adapter and any new future adapter types. Attribute
'parent' is to specify the parent for the fc_host adapter.

* docs/formatstorage.html.in:
  - Add documents for the 4 new attrs
* docs/schemas/storagepool.rng:
  - Add RNG schema
* src/conf/storage_conf.c:
  - Parse and format the new XMLs
* src/conf/storage_conf.h:
  - New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
  - New enum virStoragePoolSourceAdapterType
* src/libvirt_private.syms:
  - Export TypeToString and TypeFromString
* src/phyp/phyp_driver.c:
  - Replace "adapter" with "adapter.data.name", which is member of the union
    of the new struct virStoragePoolSourceAdapter now. Later patch will
    add the checking, as "adapter.data.name" is only valid for "scsi_host"
    adapter.
* src/storage/storage_backend_scsi.c:
  - Like above
* tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
  - New test for 'fc_host' and "scsi_host" adapter
* tests/storagepoolxml2xmlout/pool-scsi.xml:
  - Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
    specified now
* tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
  - New test
* tests/storagepoolxml2xmltest.c:
  - Include the test
2013-04-08 18:41:06 +08:00
Ján Tomko
37a10129c2 Update xml schemas according to libvirt source
capability.rng: Guest features can be in any order.
nodedev.rng: Added <driver> element, <capability> phys_function and
virt_functions for PCI devices.
storagepool.rng: Owner or group ID can be -1.

schema tests: New capabilities and nodedev files; changed owner and
group to -1 in pool-dir.xml.
storage_conf: Print uid_t and gid_t as signed to storage pool XML.
2012-08-02 14:36:23 -06:00
Sebastian Wiedenroth
29bc4fe646 Add a sheepdog backend for the storage driver
This patch brings support to manage sheepdog pools and volumes to libvirt.
It uses the "collie" command-line utility that comes with sheepdog for that.

A sheepdog pool in libvirt maps to a sheepdog cluster.
It needs a host and port to connect to, which in most cases
is just going to be the default of localhost on port 7000.

A sheepdog volume in libvirt maps to a sheepdog vdi.
To create one specify the pool, a name and the capacity.
Volumes can also be resized later.

In the volume XML the vdi name has to be put into the <target><path>.
To use the volume as a disk source for virtual machines specify
the vdi name as "name" attribute of the <source>.
The host and port information from the pool are specified inside the host tag.

  <disk type='network'>
    ...
    <source protocol="sheepdog" name="vdi_name">
      <host name="localhost" port="7000"/>
    </source>
  </disk>

To work right this patch parses the output of collie,
so it relies on the raw output option. There recently was a bug which caused
size information to be reported wrong. This is fixed upstream already and
will be in the next release.

Signed-off-by: Sebastian Wiedenroth <wiedi@frubar.net>
2012-07-18 20:08:27 +01:00
Wido den Hollander
74951eadef storage backend: Add RBD (RADOS Block Device) support
This patch adds support for a new storage backend with RBD support.

RBD is the RADOS Block Device and is part of the Ceph distributed storage
system.

It comes in two flavours: Qemu-RBD and Kernel RBD, this storage backend only
supports Qemu-RBD, thus limiting the use of this storage driver to Qemu only.

To function this backend relies on librbd and librados being present on the
local system.

The backend also supports Cephx authentication for safe authentication with
the Ceph cluster.

For storing credentials it uses the built-in secret mechanism of libvirt.

Signed-off-by: Wido den Hollander <wido@widodh.nl>
2012-05-21 12:37:38 -06:00
Patrick Dignan
20be699ee3 storage: add support for Vendor and Model in XML
I wrote a patch to add support for listing the Vendor and Model of a
storage pool in the storage pool XML.  This would allow vendor
extensions of specific devices.  The patch includes a test for the new
attributes as well.

Patrick Dignan
2010-08-19 15:58:43 -06:00
David Allan
77da2487ea Add multiIQN tests
* Fix broken rng schema
* Add test input & output files
2010-06-08 13:14:26 -04:00
Cole Robinson
a7fb2258ca storage: Sanitize pool target paths
Spurious / in a pool target path makes life difficult for apps using the
GetVolByPath, and doing other path based comparisons with pools. This
has caused a few issues for virt-manager users:

https://bugzilla.redhat.com/show_bug.cgi?id=494005
https://bugzilla.redhat.com/show_bug.cgi?id=593565

Add a new util API which removes spurious /, virFileSanitizePath. Sanitize
target paths when parsing pool XML, and for paths passed to GetVolByPath.

v2: Leading // must be preserved, properly sanitize path=/, sanitize
    away /./ -> /

v3: Properly handle starting ./ and ending /.

v4: Drop all '.' handling, just sanitize / for now.
2010-05-25 12:30:44 -04:00
Cole Robinson
e1ea1b2af7 tests: Add XML 2 XML tests for storage pools.
Move existing schema data to an input directory. Add extra files for more
thorough XML testing.
2009-10-16 10:21:47 -04:00