Commit Graph

11 Commits

Author SHA1 Message Date
Michal Privoznik
7c9a2d88cd virutil: Move string related functions to virstring.c
The source code base needs to be adapted as well. Some files
include virutil.h just for the string related functions (here,
the include is substituted to match the new file), some include
virutil.h without any need (here, the include is removed), and
some require both.
2013-05-02 16:56:55 +02:00
Osier Yang
9f781da69d New XML attributes for storage pool source adapter
This introduces 4 new attributes for storage pool source adapter.
E.g.

<adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>

Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
for 'scsi_host' adapter, for back-compat reason. However, mandatory
for 'fc_host' adapter and any new future adapter types. Attribute
'parent' is to specify the parent for the fc_host adapter.

* docs/formatstorage.html.in:
  - Add documents for the 4 new attrs
* docs/schemas/storagepool.rng:
  - Add RNG schema
* src/conf/storage_conf.c:
  - Parse and format the new XMLs
* src/conf/storage_conf.h:
  - New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
  - New enum virStoragePoolSourceAdapterType
* src/libvirt_private.syms:
  - Export TypeToString and TypeFromString
* src/phyp/phyp_driver.c:
  - Replace "adapter" with "adapter.data.name", which is member of the union
    of the new struct virStoragePoolSourceAdapter now. Later patch will
    add the checking, as "adapter.data.name" is only valid for "scsi_host"
    adapter.
* src/storage/storage_backend_scsi.c:
  - Like above
* tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
  - New test for 'fc_host' and "scsi_host" adapter
* tests/storagepoolxml2xmlout/pool-scsi.xml:
  - Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
    specified now
* tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
  - New test
* tests/storagepoolxml2xmltest.c:
  - Include the test
2013-04-08 18:41:06 +08:00
Sebastian Wiedenroth
29bc4fe646 Add a sheepdog backend for the storage driver
This patch brings support to manage sheepdog pools and volumes to libvirt.
It uses the "collie" command-line utility that comes with sheepdog for that.

A sheepdog pool in libvirt maps to a sheepdog cluster.
It needs a host and port to connect to, which in most cases
is just going to be the default of localhost on port 7000.

A sheepdog volume in libvirt maps to a sheepdog vdi.
To create one specify the pool, a name and the capacity.
Volumes can also be resized later.

In the volume XML the vdi name has to be put into the <target><path>.
To use the volume as a disk source for virtual machines specify
the vdi name as "name" attribute of the <source>.
The host and port information from the pool are specified inside the host tag.

  <disk type='network'>
    ...
    <source protocol="sheepdog" name="vdi_name">
      <host name="localhost" port="7000"/>
    </source>
  </disk>

To work right this patch parses the output of collie,
so it relies on the raw output option. There recently was a bug which caused
size information to be reported wrong. This is fixed upstream already and
will be in the next release.

Signed-off-by: Sebastian Wiedenroth <wiedi@frubar.net>
2012-07-18 20:08:27 +01:00
Martin Kletzander
9943276fd2 Cleanup for a return statement in source files
Return statements with parameter enclosed in parentheses were modified
and parentheses were removed. The whole change was scripted, here is how:

List of files was obtained using this command:
git grep -l -e '\<return\s*([^()]*\(([^()]*)[^()]*\)*)\s*;' |             \
grep -e '\.[ch]$' -e '\.py$'

Found files were modified with this command:
sed -i -e                                                                 \
's_^\(.*\<return\)\s*(\(\([^()]*([^()]*)[^()]*\)*\))\s*\(;.*$\)_\1 \2\4_' \
-e 's_^\(.*\<return\)\s*(\([^()]*\))\s*\(;.*$\)_\1 \2\3_'

Then checked for nonsense.

The whole command looks like this:
git grep -l -e '\<return\s*([^()]*\(([^()]*)[^()]*\)*)\s*;' |             \
grep -e '\.[ch]$' -e '\.py$' | xargs sed -i -e                            \
's_^\(.*\<return\)\s*(\(\([^()]*([^()]*)[^()]*\)*\))\s*\(;.*$\)_\1 \2\4_' \
-e 's_^\(.*\<return\)\s*(\([^()]*\))\s*\(;.*$\)_\1 \2\3_'
2012-03-26 14:45:22 -06:00
Eric Blake
8fe454ce90 build: expand rule to cover testsuite
The bulk of this patch was done with:

sed -i 's/\(\bfree *(/VIR_FREE(/g' tests/*.c

followed by fixing the few compile errors that resulted.

* cfg.mk (exclude_file_name_regexp--sc_prohibit_raw_allocation):
Remove tests from exemption.
* tests/testutils.h: Add common header.
* tests/commandhelper.c: Fix offenders.
* tests/cputest.c: Likewise.
* tests/domainsnapshotxml2xmltest.c: Likewise.
* tests/interfacexml2xmltest.c: Likewise.
* tests/networkxml2argvtest.c: Likewise.
* tests/networkxml2xmltest.c: Likewise.
* tests/nodedevxml2xmltest.c: Likewise.
* tests/nodeinfotest.c: Likewise.
* tests/nwfilterxml2xmltest.c: Likewise.
* tests/qemuargv2xmltest.c: Likewise.
* tests/qemuxml2argvtest.c: Likewise.
* tests/qemuxml2xmltest.c: Likewise.
* tests/qemuxmlnstest.c: Likewise.
* tests/qparamtest.c: Likewise.
* tests/sexpr2xmltest.c: Likewise.
* tests/storagepoolxml2xmltest.c: Likewise.
* tests/storagevolxml2xmltest.c: Likewise.
* tests/testutils.c: Likewise.
* tests/virshtest.c: Likewise.
* tests/xencapstest.c: Likewise.
* tests/xmconfigtest.c: Likewise.
* tests/xml2sexprtest.c: Likewise.
2012-02-03 10:41:46 -07:00
Matthias Bolte
9ba4eb3c08 tests: Lower stack usage below 4096 bytes
Make virtTestLoadFile allocate the buffer to read the file into.

Fix logic error in virtTestLoadFile, stop reading on the first empty line.

Use virFileReadLimFD in virtTestCaptureProgramOutput to avoid manual
buffer handling.
2011-04-30 19:59:52 +02:00
Eric Blake
20986e58aa tests: simplify common setup
A few of the tests were missing basic sanity checks, while most
of them were doing copy-and-paste initialization (in fact, some
of them pasted the argc > 1 check more than once!).  It's much
nicer to do things in one common place, and minimizes the size of
the next patch that fixes getcwd usage.

* tests/testutils.h (EXIT_AM_HARDFAIL): New define.
(progname, abs_srcdir): Define for all tests.
(VIRT_TEST_MAIN): Change callback signature.
* tests/testutils.c (virtTestMain): Do more common init.
* tests/commandtest.c (mymain): Simplify.
* tests/cputest.c (mymain): Likewise.
* tests/esxutilstest.c (mymain): Likewise.
* tests/eventtest.c (mymain): Likewise.
* tests/hashtest.c (mymain): Likewise.
* tests/networkxml2xmltest.c (mymain): Likewise.
* tests/nodedevxml2xmltest.c (myname): Likewise.
* tests/nodeinfotest.c (mymain): Likewise.
* tests/nwfilterxml2xmltest.c (mymain): Likewise.
* tests/qemuargv2xmltest.c (mymain): Likewise.
* tests/qemuhelptest.c (mymain): Likewise.
* tests/qemuxml2argvtest.c (mymain): Likewise.
* tests/qemuxml2xmltest.c (mymain): Likewise.
* tests/qparamtest.c (mymain): Likewise.
* tests/sexpr2xmltest.c (mymain): Likewise.
* tests/sockettest.c (mymain): Likewise.
* tests/statstest.c (mymain): Likewise.
* tests/storagepoolxml2xmltest.c (mymain): Likewise.
* tests/storagevolxml2xmltest.c (mymain): Likewise.
* tests/virbuftest.c (mymain): Likewise.
* tests/virshtest.c (mymain): Likewise.
* tests/vmx2xmltest.c (mymain): Likewise.
* tests/xencapstest.c (mymain): Likewise.
* tests/xmconfigtest.c (mymain): Likewise.
* tests/xml2sexprtest.c (mymain): Likewise.
* tests/xml2vmxtest.c (mymain): Likewise.
2011-04-29 10:21:20 -06:00
Patrick Dignan
20be699ee3 storage: add support for Vendor and Model in XML
I wrote a patch to add support for listing the Vendor and Model of a
storage pool in the storage pool XML.  This would allow vendor
extensions of specific devices.  The patch includes a test for the new
attributes as well.

Patrick Dignan
2010-08-19 15:58:43 -06:00
David Allan
77da2487ea Add multiIQN tests
* Fix broken rng schema
* Add test input & output files
2010-06-08 13:14:26 -04:00
Daniel P. Berrange
031366383a Remove virConnectPtr from storage APIs & driver
The virConnectPtr is no longer required for error reporting since
that is recorded in a thread local. Remove use of virConnectPtr
from all APIs in storage_conf.{h,c} and storage_encryption_conf.{h,c}
and update all callers to match
2010-02-10 13:32:11 +00:00
Cole Robinson
e1ea1b2af7 tests: Add XML 2 XML tests for storage pools.
Move existing schema data to an input directory. Add extra files for more
thorough XML testing.
2009-10-16 10:21:47 -04:00