Martin Kletzander
aca4d72b2a Include sysmacros.h where needed
So in glibc-2.23 sys/sysmacros.h is no longer included from sys/types.h
and we don't build because of the usage of major/minor/makedev macros.
Autoconf already has AC_HEADER_MAJOR macro that check where exactly
these functions/macros are defined, so let's use that.

Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
2016-04-18 20:36:57 +02:00
Olga Krishtal
ee36975597 storage: add ploop volume type
Ploop image consists of directory with two files: ploop image itself,
called root.hds and DiskDescriptor.xml that contains information about
ploop device: https://openvz.org/Ploop/format.
Such volume are difficult to manipulate in terms of existing volume types
because they are neither a single files nor a directory.
This patch introduces new volume type - ploop. This volume type is used
by ploop volume's exclusively.

Signed-off-by: Olga Krishtal <okrishtal@virtuozzo.com>
Signed-off-by: Ján Tomko <jtomko@redhat.com>
2016-04-15 17:27:32 +02:00
Peter Krempa
d6cb0d256a domain: Add helper to determine presence of memory baloon 2016-04-15 14:27:08 +02:00
Laine Stump
bc07251f59 conf: new pci controller model pcie-expander-bus
This controller provides a single PCIe port on a new root. It is
similar to pci-expander-bus, intended to provide a bus that can be
associated with a guest-identifiable NUMA node, but is for
machinetypes with PCIe rather than PCI (e.g. q35-based machinetypes).

Aside from PCIe vs. PCI, the other main difference is that a
pci-expander-bus has a companion pci-bridge that is automatically
attached along with it, but pcie-expander-bus has only a single port,
and that port will only connect to a pcie-root-port, or to a
pcie-switch-upstream-port. In order for the bus to be of any use in
the guest, it must have either a pcie-root-port or a
pcie-switch-upstream-port attached (and one or more
pcie-switch-downstream-ports attached to the
pcie-switch-upstream-port).
2016-04-14 14:00:34 -04:00
Laine Stump
52f3d0a4d2 conf: new pci controller model pci-expander-bus
This is a standard PCI root bus (not a bridge) that can be added to a
440fx-based domain. Although it uses a PCI slot, this is *not* how it
is connected into the PCI bus hierarchy, but is only used for
control. Each pci-expander-bus provides 32 slots (0-31) that can
accept hotplug of standard PCI devices.

The usefulness of pci-expander-bus relative to a pci-bridge is that
the NUMA node of the bus can be specified with the <node> subelement
of <target>. This gives guest-side visibility to the NUMA node of
attached devices (presuming that management apps only assign a device
to a bus that has a NUMA node number matching the node number of the
device on the host).

Each pci-expander-bus also has a "busNr" attribute. The expander-bus
itself will take the busNr specified, and all buses that are connected
to this bus (including the pci-bridge that is automatically added to
any expander bus of model "pxb" (see the next commit)) will use
busNr+1, busNr+2, etc, and the pci-root (or the expander-bus with next
lower busNr) will use bus numbers lower than busNr.
2016-04-14 14:00:34 -04:00
Laine Stump
a0616ee8a8 conf: utility function to convert PCI controller model into connect type
There are two places in qemu_domain_address.c where we have a switch
statement to convert PCI controller models
(VIR_DOMAIN_CONTROLLER_MODEL_PCI*) into the connection type flag that
is matched when looking for an upstream connection for that model of
controller (VIR_PCI_CONNECT_TYPE_*). This patch makes a utility
function in conf/domain_addr.c to do that, so that when a new PCI
controller is added, we only need to add the new model-->connect-type
in a single place.
2016-04-14 14:00:34 -04:00
Laine Stump
d1cc4605d7 conf/qemu: change the way VIR_PCI_CONNECT_TYPE_* flags work
The flags used to determine which devices could be plugged into which
controllers were quite confusing, as they tried to create classes of
connections, then put particular devices into possibly multiple
classes, while sometimes setting multiple flags for the controllers
themselves. The attempt to have a single flag indicate, e.g. that a
root-port or a switch-downstream-port could connect was not only
confusing, it was leading to a situation where it would be impossible
to specify exactly the right combinations for a new controller.

The solution is for the VIR_PCI_CONNECT_TYPE_* flags to have a 1:1
correspondence with each type of PCI controller, plus a flag for a PCI
endpoint device and another for a PCIe endpoint device (the only
exception to this is that pci-bridge and pcie-expander-bus controllers
have their upstream connection classified as
VIR_PCI_CONNECT_TYPE_PCI_DEVICE since they can be plugged into
*exactly* the same ports as any endpoint device).  Each device then
has a single flag for connect type (plus the HOTPLUG flag if that
device can e hotplugged), and each controller sets the CONNECT bits
for all controllers that can be plugged into it, as well as for either
type of endpoint device that can be plugged in (and the HOTPLUG flag
if it can accept hotplugged devices).

With this change, it is *slightly* easier to understand the matching
of connections (as long as you remember that the flag for a
device/upstream-facing connection of a controller is the same as that
device's type, while the flags for a controller's downstream
connections is the OR of all device types that can be plugged into
that controller). More importantly, it will be possible to correctly
specify what can be plugged into a pcie-switch-expander-bus, when
support for it is added.
2016-04-14 14:00:34 -04:00
Laine Stump
0d668434f4 conf: allow use of slot 0 in a dmi-to-pci-bridge
When support for dmi-to-pci-bridge was added, it was assumed that,
just as with the pci-root bus, slot 0 was reserved. This is not the
case - it can be used to connect a device just like any other slot, so
remove the restriction and update the test cases that auto-assign an
address on a dmi-to-pci-bridge.
2016-04-14 14:00:33 -04:00
Laine Stump
6d0902a5ca conf: use #define instead of literal for highest slot in upstream port
Every other maxSlot was either set to 0 or to
VIR_PCI_ADDRESS_SLOT_LAST, but this one was for some reason set to the
literal value 31 (which is the same as VIR_PCI_ADDRESS_SLOT_LAST).
This makes them all consistent.
2016-04-14 14:00:33 -04:00
Pavel Hrdina
6e76738e54 build: fix build on RHEL-6
GCC in RHEL-6 complains about listen:

../../src/conf/domain_conf.c:23718: error: declaration of 'listen' shadows a global declaration [-Wshadow]
/usr/include/sys/socket.h:204: error: shadowed declaration is here [-Wshadow]

This renames all the listen to gListen.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 17:28:50 +02:00
Peter Krempa
5be120710e Add VIR_DOMAIN_EVENT_ID_DEVICE_REMOVAL_FAILED event
Since we didn't opt to use one single event for device lifecycle for a
VM we are missing one last event if the device removal failed. This
event will be emitted once we asked to eject the device but for some
reason it is not possible.
2016-04-13 13:26:29 +02:00
Pavel Hrdina
ea4fc80230 domain_conf: call ...ListensParseXML only for appropriate graphics
Instead of calling the virDomainGraphicsListensParseXML function for all
graphics types and ignore the wrong ones move the call only to graphics
types where we supports listen elements.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 10:43:49 +02:00
Pavel Hrdina
40d246d282 domain_conf: remove unused virDomainGraphicsListenGet*
Those are the last two places that uses the getter functions.  Use a
direct access instead and remove those getters.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 10:43:49 +02:00
Pavel Hrdina
37b1f45066 domain_conf: cleanup virDomainGraphicsGetListen
Removes the check for graphics type, it's not a public API and developer
know what he's doing and this check makes no sense.  It also removes
the ability to allocate a new array if there is none.  This was used by
the virDomainGraphicsListenAdd* functions and isn't used anymore.

This is now a simple getter with simple check for listens array presence
and whether the index in out of bounds.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 10:43:49 +02:00
Pavel Hrdina
d6d17226ff domain_conf: remove unused virDomainGraphicsListenSetType
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 10:43:49 +02:00
Pavel Hrdina
39995aa480 domain_conf: remove virDomainGraphicsListenSetNetwork
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 10:43:49 +02:00
Pavel Hrdina
4b75237fe6 domain_conf: introduce virDomainGraphicsListenAppendAddress
This effectively removes virDomainGraphicsListenSetAddress which was
used only to change the address of listen structure and possible change
the listen type.  The new function will auto-expand the listens array
and append a new listen.

The old function was used on pre-allocated array of listens and in most
cases it only "add" a new listen.  The two remaining uses can access the
listen structure directly.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-13 10:43:49 +02:00
Peter Krempa
8eb1cbb8bd conf: extract disk geometry parsing code 2016-04-13 08:21:39 +02:00
Peter Krempa
b4be29336d conf: Refactor virDomainDiskDefMirrorParse
Now that the mirror parsing code is not crammed in the main disk parser
we can employ better coding style.
2016-04-13 08:21:38 +02:00
Peter Krempa
109fe3fea1 conf: disk: Split out parsing of disk mirror data
Changes are indentation and 'cleanup' label instead of 'error'.
2016-04-13 08:21:38 +02:00
Peter Krempa
14e4c4e465 conf: virDomainDiskDefIotuneParse: Report malformed number errors
Rest of the fields of the iotune data structure did not check for
malformed integers. Use the previously defined macro to extract them
which will simplify the code and add error reporting.
2016-04-13 08:21:38 +02:00
Peter Krempa
112ae48192 conf: virDomainDiskDefIotuneParse: simplify parsing
Since the structure was pre-initialized to 0 we don't need to set every
single member to 0 if it's not present in the XML. Additionally if we
put the name of the field into the error message the code can be
simplified using a macro to parse the members.
2016-04-13 08:21:27 +02:00
Peter Krempa
71760e90d2 conf: disk: Remove error label from virDomainDiskDefIotuneParse
Since this function isn't doing any cleanup, the label is not necessary.
2016-04-13 08:20:45 +02:00
Peter Krempa
5fce412d9a conf: disk: Extract iotune parsing into a separate func 2016-04-13 08:20:44 +02:00
Peter Krempa
65da41de14 conf: disk: Remove one unnecessary level of indentation
Also simplify the code by switching to a for loop.
2016-04-13 08:20:44 +02:00
Peter Krempa
4bbac0f9b9 conf: disk: Don't initialize fields allocated by calloc
All the fields were initialized to 0.
2016-04-13 08:20:44 +02:00
Peter Krempa
dcf02a704f util: Rename and move virStrIsPrint to virStringIsPrintable 2016-04-13 08:15:24 +02:00
Ján Tomko
1278688921 conf: use VIR_APPEND_ELEMENT in virDomainDefAddImplicitVideo 2016-04-12 10:45:35 +02:00
Ján Tomko
1485be1784 conf: reduce indentation in virDomainDefAddImplicitVideo
Return early if there is nothing to do.
2016-04-12 10:45:35 +02:00
Ján Tomko
35e3c4a684 conf: delete useless primaryVideo variable
If we encounter a video device with primary=yes, we insert it
at def->videos[0].

There is no need to record this in a separate variable,
just check if there already is a primary video at def->videos[0].
2016-04-12 10:45:35 +02:00
Ján Tomko
b2b8fc919d conf: use insertAt instead of j
We call VIR_INSERT_ELEMENT_INPLACE either with 0 (for primary video)
or def->nvideos (for the rest).

Use a variable with more semantic name, since j is usually used
for iterating.
2016-04-12 10:45:35 +02:00
Ján Tomko
ca70db398e conf: use the iterator directly when parsing video devices
We start with both i and def->nvideos at 0 and increment both
after every successful iteration.

Use i directly, instead of passing the def->nvideos value through j.
2016-04-12 10:45:35 +02:00
Ján Tomko
6d8b6d2847 conf: also mark the implicit video as primary
Commit 119cd06 started setting the primary bool for the first
user-specified video even if user omitted the 'primary' attribute.

However this was done before the addition of the implicit device.
This broke startup of transient qemu domains with no <video>:
https://bugzilla.redhat.com/show_bug.cgi?id=1325757

Move this default to virDomainDefPostParseInternal,
after the addition of the implicit video device, to catch the implicit
video as well.
2016-04-12 10:45:35 +02:00
Ján Tomko
6879be484c conf: move default video addition after XML parsing
Separate parsing of the XML from auto-generating the device.
2016-04-12 10:45:35 +02:00
Pavel Hrdina
1d9d0c9397 domain_conf: fix graphics parsing
Commit dc98a5bc refactored the code a lot and forget about checking if
listen attribute is specified.  This ensures that listen attribute and
first listen element are compared only if both exist.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-11 13:50:55 +02:00
Pavel Hrdina
0159b38324 domain_conf: cleanup error paths for graphics parser
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-08 17:50:48 +02:00
Pavel Hrdina
537d32a2fd domain_conf: split graphics xml parser into multiple functions
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-08 17:36:27 +02:00
Pavel Hrdina
dc98a5bc59 domain_conf: cleanup virDomainGraphicsListensParseXML
Refactor the listen parser to use only one loop.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-08 17:36:27 +02:00
Pavel Hrdina
ffce6090f6 domain_conf: introduce virDomainGraphicsListensParseXML
Move code, that parses graphics listens, to its own function.

Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
2016-04-08 17:36:27 +02:00
Vasiliy Tolstov
690969af9c libvirt domain xml allow to set peer address
Signed-off-by: Vasiliy Tolstov <v.tolstov@selfip.ru>
2016-04-07 18:23:01 +01:00
Peter Krempa
e0a34e76ef conf: store bootindex as unsigned int
The value is never negative thus there's no need to store it in a signed
type.
2016-04-06 09:27:23 +02:00
Peter Krempa
836bf4ba7c conf: Pass the whole device info struct to virDomainDeviceBootParseXML
No need to extract the single element.
2016-04-06 09:27:23 +02:00
Martin Kletzander
17a94ba70f nodedev: Fix parsing of generated XMLs
Commit d77ffb6876 added not only reporting of the PCI header type, but
also parsing of that information.  However, because there was no parsing
done for the other sub-PCI capabilities, if there was any other
capability then a valid header type name (like phys_function or
virt_functions) the parsing would fail.  This prevented passing node
device XMLs that we generated into our own functions when dealing with,
e.g. with SRIOV cards.

Instead of reworking the whole parsing, just fix this one occurence and
remove a test for it for the time being.  Future patches will deal with
the rest.

Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
2016-04-04 14:24:02 +02:00
Peter Krempa
5c633e0f7b conf: Remove now unused virDomainIOThreadIDMap 2016-03-29 21:26:07 +02:00
Peter Krempa
0b4b58690d conf: decrease iterations complexity when formatting iothreads
Create a bitmap of iothreads that have scheduler info set so that the
transformation algorithm does not have to iterate the empty bitmap many
times. By reusing self-expanding bitmaps the bitmap size does not need
to be pre-calculated.

Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1264008
2016-03-29 21:26:06 +02:00
Qiaowei Ren
afe833e9bd perf: add new xml element
This patch adds new xml element, and so we can have the option of
also having perf events enabled immediately at startup.

Signed-off-by: Qiaowei Ren <qiaowei.ren@intel.com>
Message-id: 1459171833-26416-6-git-send-email-qiaowei.ren@intel.com
2016-03-29 13:13:05 +01:00
Maxim Nestratov
7068b56c85 conf: qemu: Add support for more HyperV Enlightenment features
This patch adds support for "vpindex", "runtime", "synic",
"stimer", and "vendor_id" features available in qemu 2.5+.

- When Hyper-V "vpindex" is on, guest can use MSR HV_X64_MSR_VP_INDEX
to get virtual processor ID.

- Hyper-V "runtime" enlightement feature allows to use MSR
HV_X64_MSR_VP_RUNTIME to get the time the virtual processor consumes
running guest code, as well as the time the hypervisor spends running
code on behalf of that guest.

- Hyper-V "synic" stands for Synthetic Interrupt Controller, which is
lapic extension controlled via MSRs.

- Hyper-V "stimer" switches on Hyper-V SynIC timers MSR's support.
Guest can setup and use fired by host events (SynIC interrupt and
appropriate timer expiration message) as guest clock events

- Hyper-V "reset" allows guest to reset VM.

- Hyper-V "vendor_id" exposes hypervisor vendor id to guest.

Signed-off-by: Nikolay Shirokovskiy <nshirokovskiy@virtuozzo.com>
Signed-off-by: John Ferlan <jferlan@redhat.com>
2016-03-28 13:10:18 -04:00
Nikolay Shirokovskiy
2e26d78c8b conf: refactor hyperv features xml output
1. All hyperv features are tristate ones. So make tristate generating part common.
2. Reduce nesting on spinlocks.

Signed-off-by: Nikolay Shirokovskiy <nshirokovskiy@virtuozzo.com>
Signed-off-by: John Ferlan <jferlan@redhat.com>
2016-03-28 13:10:18 -04:00
Nikolay Shirokovskiy
ae37d9f1d1 conf: refactor hyperv features parsing
1. All hyperv features are tristate ones. So make tristate parsing code common.
2. Reindent switch statement.
3. Reduce nesting in spinlocks parsing.

Signed-off-by: Nikolay Shirokovskiy <nshirokovskiy@virtuozzo.com>
Signed-off-by: John Ferlan <jferlan@redhat.com>
2016-03-28 13:10:18 -04:00
Bjoern Walk
a243316ac6 conf: node_device: fix up SCSI target
When reading in an XML definition for a SCSI target device, the name
property of struct scsi_target refers to the @target element.

Let's fix this obvious typo and also extend the XML schema to provide
validation.

Signed-off-by: Bjoern Walk <bwalk@linux.vnet.ibm.com>
2016-03-21 12:06:49 -04:00