At the very beginning of the attach function the
qemuDomainStorageSourceChainAccessAllow() is called which
modifies CGroups, locks and seclabels for new disk and its
backing chain. This must be followed by a counterpart which
reverts back all the changes if something goes wrong. This boils
down to calling qemuDomainStorageSourceChainAccessRevoke() which
is done under 'error' label. But not all failure branches jump
there. They just jump onto 'cleanup' label where no revoke is
done. Such mistake is easy to do because 'cleanup' label does
exist. Therefore, dissolve 'error' block in 'cleanup' and have
everything jump onto 'cleanup' label.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Our normal practice is for the object type to be the name prefix, and
the object instance be the first parameter passed in.
Rename these to virDomainObjSave and virDomainDefSave moving their
primary parameter to be the first one. Ensure that the xml options
are passed into both functions in prep for future work.
Finally enforce checking of the return type and mark all parameters
as non-NULL.
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Signed-off-by: Daniel P. Berrangé <berrange@redhat.com>
This also isn't required (due to the vportprofile being stored in the
NetDef as a pointer rather than being directly contained), but it
seemed dishonest to not mark it as const (and thus permit users to
modify its contents)
Signed-off-by: Laine Stump <laine@redhat.com>
Reviewed-by: Cole Robinson <crobinso@redhat.com>
In this case, the virNetDevBandwidthPtr that is returned is not to a
region within the virDomainNetDef arg, but points elsewhere (the
NetDef has the pointer, not the entire object), so technically it's
not necessary to make the return value a const, but it's a bit
disingenuous to *not* do it.
Signed-off-by: Laine Stump <laine@redhat.com>
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Signed-off-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
The current 'setvcpus' timeout message requires a deeper
understanding of QEMU/Libvirt internals to proper react to it.
One who knows how setvcpus unplug work (it is an asynchronous
operation between QEMU and guest that Libvirt can't know for
sure if it failed, unless an explicit error happened during the
timeout period) will read the message and not assume a failed
operation. But the regular user, most often than not, will read
it and believe that the unplug operation failed.
This leads to situations where the user isn't exactly relieved
when accessing the guest and seeing that the unplug operation
worked. Instead, the user feel mislead by the timeout message
setvcpus threw.
Changing the timeout message to let the user know that the
unplug status is not known, and manual inspection in the guest
is required, is not a silver bullet. But it gives a more
realistic expectation of what happened, as best as we can tell
from Libvirt side anyways.
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Signed-off-by: Daniel Henrique Barboza <danielhb413@gmail.com>
qemu_hotplugpriv.h is a header file created to share a global variable
called 'qemuDomainRemoveDeviceWaitTime', declared in qemu_hotplug.c,
to other files that would want to change the timeout value
(currently, only tests/qemuhotplugtest.c).
Previous patch deprecated the variable, using qemu_driver->unplugTimeout
to set the timeout instead. This means that the header file is now
unused, and can be safely discarded.
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Signed-off-by: Daniel Henrique Barboza <danielhb413@gmail.com>
For some architectures and setups, device removal can take
longer than the default 5 seconds. This results in commands
such as 'virsh setvcpus' to fire timeout messages even if
the operation were successful in the guest, confusing the
user.
This patch sets a new 10 seconds unplug timeout for PPC64
guests. All other archs will keep the default 5 seconds
timeout.
Instead of putting 'if PPC64' conditionals inside qemu_hotplug.c
to set the new timeout value, a new function called
qemuDomainGetUnplugTimeout was added. The timeout value is then
retrieved when needed, by passing the correspondent DomainDef
object. This approach allows for different guest architectures
to have distint unplug timeout intervals, regardless of the
host architecture. This design also makes it easier to
modify/enhance the unplug timeout logic in the future
(allow for special timeouts for TCG domains, for example).
A new mock file was created to work with qemuhotplugtest.c,
given that the test timeout is significantly shorter than
the actual timeout value in qemu_hotplug.c.
The now unused 'qemuDomainRemoveDeviceWaitTime' global can't
be simply erased from qemu_hotplug.c though. Next patch will
remove it properly.
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Suggested-by: Cole Robinson <crobinso@redhat.com>
Signed-off-by: Daniel Henrique Barboza <danielhb413@gmail.com>
When attaching a mediated host device of model vfio-ccw without
specifying a guest-address, none is generated by libvirt. Let's fix this
and make sure to generate a device address during live-hotplug.
Reviewed-by: Boris Fiuczynski <fiuczy@linux.ibm.com>
Signed-off-by: Bjoern Walk <bwalk@linux.ibm.com>
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
Commit 01ca4010d8 (libvirt v5.1.0) moved address reservation for
hotplugged interface devices up to an earlier point in
qemuDomainAttachNetDevice(), because that function calls
qemuDomainSupportsNicdev() (in the case of
VIR_DOMAIN_NET_TYPE_VHOSTUSER), and qemuDomainSupportsNicdev() needs
to know the address type (for ARM machinetypes) and returns incorrect
results when the address type is "none".
This bugfix unfortunately caused a regression, because it also made PCI
address reservation happen before we noticed that the device was a
*hostdev* interface. Those interfaces are hotplugged by just calling
out to qemuDomainAttachHostdevDevice() - that function would then also
attempt to reserve the *same PCI address* that had just been reserved
in qemuDomainAttachNetDevice().
The solution is to move the bit of code that short-circuits out to
virDomainHostdevAttach() up *even earlier* so that no PCI address has
been allocated by the time it's called.
https://bugzilla.redhat.com/show_bug.cgi?id=1744523
Signed-off-by: Laine Stump <laine@redhat.com>
Reviewed-by: Andrea Bolognani <abologna@redhat.com>
In both replaced cases we have other code that verifies that the bus
can't be changed or that the target is unique, so limiting the search to
disks with same bus makes no sense.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Daniel Henrique Barboza <danielhb413@gmail.com>
In some places we need to check if a hostdev has VFIO backend.
Because of how complicated virDomainHostdevDef structure is, the
check consists of three lines. Move them to a function and
replace all checks with the function call.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Replace all occurrences of
if (VIR_STRDUP(a, b) < 0)
/* effectively dead code */
with:
a = g_strdup(b);
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Replace:
if (!s && VIR_STRDUP(s, str) < 0)
goto;
with:
if (!s)
s = g_strdup(str);
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Now that all the types using VIR_AUTOUNREF have a cleanup func defined
to virObjectUnref, use g_autoptr instead of VIR_AUTOUNREF.
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Since commit 44e7f02915
util: rewrite auto cleanup macros to use glib's equivalent
VIR_AUTOPTR aliases to g_autoptr. Replace all of its use by the GLib
macro version.
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Since commit 44e7f02915
util: rewrite auto cleanup macros to use glib's equivalent
VIR_AUTOFREE is just an alias for g_autofree. Use the GLib macros
directly instead of our custom aliases.
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Also define the macro for building with GLib older than 2.60
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Use G_GNUC_UNUSED from GLib instead of ATTRIBUTE_UNUSED.
Signed-off-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Cleanup labels are also dropped where possible.
Signed-off-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Reviewed-by: Erik Skultety <eskultet@redhat.com>
The fact that qemu is capable -netdev socket is not enough to
start a migratable domain. It also needs dbus-vmstate capability.
Since there are already some qemu releases which have
net-socket-dgram capability and don't have dbus-vmstate we need
to check for dbus-vmstate.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
qemuDomainAttachNetDevice() (hotplug) previously had some of the
validation that is in qemuDomainValidateActualNetDef(), but it was
incomplete. qemuDomainChangeNet() had none of that validation, but it
is all appropriate in both cases.
This is the final piece of a previously partial resolution to
https://bugzilla.redhat.com/1502754
Signed-off-by: Laine Stump <laine@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
This fixes bug in
commit bbe2aa627f
Author: Daniel P. Berrangé <berrange@redhat.com>
Date: Thu Jul 26 17:24:30 2018 +0100
conf: simplify link from hostdev back to network device
hostdevs have a link back to the original network device. This is fairly
generic accepting any type of device, however, we don't intend to make
use of this approach in future. It can thus be specialized to network
devices.
Reviewed-by: Cole Robinson <crobinso@redhat.com>
Signed-off-by: Daniel P. Berrangé <berrange@redhat.com>
which mistakenly deleted the assignment to the 'net' variable,
which meant we never invoked the network driver release callback
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Signed-off-by: Daniel P. Berrangé <berrange@redhat.com>
When starting a domain, we use the presence of a vfio-pci or
mdev hostdev to determine if the memlock maximum needs to be
increased. But if we hotplug either of these devices, only the
vfio-pci path gets that love. This means that attaching a, say,
vfio-ccw device will appear to succeed but the device may be
unusable as the guest may see I/O errors on long CCW chains.
The host, meanwhile, would be flooded with these messages:
vfio_pin_page_external: Task qemu-system-s39 (11584) RLIMIT_MEMLOCK (65536) exceeded
Let's adjust the maximum memlock value in the mdev hotplug path,
so that the domain has the same value as if it were started with
one or more mdev devices in its configuration.
Signed-off-by: Eric Farman <farman@linux.ibm.com>
Reviewed-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
If attaching a PCI hostdev fails, there are several things that
need to be un-done as part of the cleanup. One thing that is
not done is re-calculating/re-setting the maximum amount of locked
memory for the domain, since we may have changed that.
Let's fix that, just to ensure everything is back the way it was.
Signed-off-by: Eric Farman <farman@linux.ibm.com>
Reviewed-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
Let's pull this hunk out into a function, so it can be reused
in another codepath that needs to do the same thing.
Signed-off-by: Eric Farman <farman@linux.ibm.com>
Reviewed-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
If a slirp-helper is associated with a network interface (after
probing & preparing succesfully), pass the socket fd to QEMU and use
"-net socket,fd=".
Signed-off-by: Marc-André Lureau <marcandre.lureau@redhat.com>
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
Add dbusVMStates to keep a list of dbus-vmstate objects needed for
migration. They are populated on the command line during start or
qemuDBusVMStateAdd/Remove() will hotplug them as needed.
Signed-off-by: Marc-André Lureau <marcandre.lureau@redhat.com>
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
With blockdev we must issue the block_set_io_throttle QMP command to
setup disk throttling as we currently can't do it with the 'throttle'
layer.
Unfortunately there's nothing we can do if it fails.
https://bugzilla.redhat.com/show_bug.cgi?id=1733163
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
KVM style of PCI devices assignment was dropped in kernel in
favor of vfio pci (see kernel commit v4.12-rc1~68^2~65). Since
vfio is around for quite some time now and is far superior
discourage people in using KVM style.
Ideally, I'd make QEMU_CAPS_VFIO_PCI implicitly assumed but turns
out qemu-3.0.0 doesn't support vfio-pci device for RISC-V.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
Reviewed-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Tested-by: Daniel Henrique Barboza <danielhb413@gmail.com>
The format string for a PCI address is copied over and over
again, often with slight adjustments. Introduce global
VIR_PCI_DEVICE_ADDRESS_FMT macro that holds the formatting string
and use it wherever possible.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
When removing the disk fronted while any block job is still active we
need to transfer the ownership of the backing chain to the job itself as
the job still holds the reference to the chain members and thus attempts
to remove them would fail.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
The PR manager is a property of the format layer in qemu so we need to
be able to track it also in the chains of orphaned block jobs.
Add a helper for qemu to look also into the blockjob state.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
when a disk without PR perform attach or detach operation,
need not call qemuHotplugRemoveManagedPR, otherwise, it will
print err log about PR, let us fix it.
Signed-off-by: Jie Wang <wangjie88@huawei.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>
When changing media using blockdev-add we need to remove the leftovers
if we didn't succeed plugging in the full chain or closing the tray.
Otherwise the data structures will be freed and thus the backing chain
members will never be unplugged.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
As this conversion removes the last use of qemuHotplugDiskSource*
functions we can remove all of them now.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
Use the new helpers for removing the backing chain in case when
-blockdev is used. For -drive this function has a local implementation.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
Replace the use of qemuHotplugDiskSourceAttach* helpers with
qemuBuildStorageSourceChainAttachPrepare(Blockdev|Drive).
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
We use only one copy-on-read filter per disk, so we should handle it
separately from the chain.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
Move it to qemu_block.c and call it qemuBlockStorageSourceDetachPrepare.
It will be reused in other parts as well.
Signed-off-by: Peter Krempa <pkrempa@redhat.com>
Reviewed-by: Ján Tomko <jtomko@redhat.com>
If libvirt receives DISCONNECTED event and prDaemonRunning is set
to false, and qemuDomainRemoveDiskDevice() is performing in the
meantime, then qemuDomainRemoveDiskDevice() will fail to remove
pr-helper object because prDaemonRunning is false. But removing
that check from qemuHotplugRemoveManagedPR() is not enough,
because after removing the object through monitor the
qemuProcessKillManagedPRDaemon() is called which contains the
same check. Thus the pr-helper process might be left behind.
Signed-off-by: Jie Wang <wangjie88@huawei.com>
Reviewed-by: Michal Privoznik <mprivozn@redhat.com>