While trying to compare netfs against my new gluster pool, I
discovered two things:
virt-xml-validate chokes on valid xml produced by 'virsh pool-dumpxml'
[yet another reason that ALL patches that add new xml should be adding
corresponding tests]
When using glusterfs FUSE mounts, you cannot access a subdirectory
of a gluster volume. The recommended workaround in the gluster
community is to mount the volume to an intermediate location, then
bind-mount the desired subdirectory to the final location. Maybe
we should teach libvirt to do bind-mounting, but for now I chose to
just document the limitation.
* docs/storage.html.in: Improve documentation.
* docs/schemas/storagepool.rng (sourcefmtnetfs): Allow all
formats, and drop redundant info-vendor.
* tests/storagepoolxml2xmltest.c (mymain): New test.
* tests/storagepoolxml2xmlin/pool-netfs-gluster.xml: New file.
* tests/storagepoolxml2xmlout/pool-netfs-gluster.xml: Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
The test case average timing code has not been used by any test
case ever. Delete it to remove complexity.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
When using logical pools, we had to trust the target->path provided.
This parameter, however, can be completely ommited and we can use
'/dev/<source.name>' safely and populate it to target.path.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=952973
Actually, I'm turning this function into a macro as filename,
function name and line number needs to be passed. The new
function virAsprintfInternal is introduced with the extended set
of arguments.
The source code base needs to be adapted as well. Some files
include virutil.h just for the string related functions (here,
the include is substituted to match the new file), some include
virutil.h without any need (here, the include is removed), and
some require both.
This introduces 4 new attributes for storage pool source adapter.
E.g.
<adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>
Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
for 'scsi_host' adapter, for back-compat reason. However, mandatory
for 'fc_host' adapter and any new future adapter types. Attribute
'parent' is to specify the parent for the fc_host adapter.
* docs/formatstorage.html.in:
- Add documents for the 4 new attrs
* docs/schemas/storagepool.rng:
- Add RNG schema
* src/conf/storage_conf.c:
- Parse and format the new XMLs
* src/conf/storage_conf.h:
- New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
- New enum virStoragePoolSourceAdapterType
* src/libvirt_private.syms:
- Export TypeToString and TypeFromString
* src/phyp/phyp_driver.c:
- Replace "adapter" with "adapter.data.name", which is member of the union
of the new struct virStoragePoolSourceAdapter now. Later patch will
add the checking, as "adapter.data.name" is only valid for "scsi_host"
adapter.
* src/storage/storage_backend_scsi.c:
- Like above
* tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
- New test for 'fc_host' and "scsi_host" adapter
* tests/storagepoolxml2xmlout/pool-scsi.xml:
- Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
specified now
* tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
- New test
* tests/storagepoolxml2xmltest.c:
- Include the test
This patch brings support to manage sheepdog pools and volumes to libvirt.
It uses the "collie" command-line utility that comes with sheepdog for that.
A sheepdog pool in libvirt maps to a sheepdog cluster.
It needs a host and port to connect to, which in most cases
is just going to be the default of localhost on port 7000.
A sheepdog volume in libvirt maps to a sheepdog vdi.
To create one specify the pool, a name and the capacity.
Volumes can also be resized later.
In the volume XML the vdi name has to be put into the <target><path>.
To use the volume as a disk source for virtual machines specify
the vdi name as "name" attribute of the <source>.
The host and port information from the pool are specified inside the host tag.
<disk type='network'>
...
<source protocol="sheepdog" name="vdi_name">
<host name="localhost" port="7000"/>
</source>
</disk>
To work right this patch parses the output of collie,
so it relies on the raw output option. There recently was a bug which caused
size information to be reported wrong. This is fixed upstream already and
will be in the next release.
Signed-off-by: Sebastian Wiedenroth <wiedi@frubar.net>
Return statements with parameter enclosed in parentheses were modified
and parentheses were removed. The whole change was scripted, here is how:
List of files was obtained using this command:
git grep -l -e '\<return\s*([^()]*\(([^()]*)[^()]*\)*)\s*;' | \
grep -e '\.[ch]$' -e '\.py$'
Found files were modified with this command:
sed -i -e \
's_^\(.*\<return\)\s*(\(\([^()]*([^()]*)[^()]*\)*\))\s*\(;.*$\)_\1 \2\4_' \
-e 's_^\(.*\<return\)\s*(\([^()]*\))\s*\(;.*$\)_\1 \2\3_'
Then checked for nonsense.
The whole command looks like this:
git grep -l -e '\<return\s*([^()]*\(([^()]*)[^()]*\)*)\s*;' | \
grep -e '\.[ch]$' -e '\.py$' | xargs sed -i -e \
's_^\(.*\<return\)\s*(\(\([^()]*([^()]*)[^()]*\)*\))\s*\(;.*$\)_\1 \2\4_' \
-e 's_^\(.*\<return\)\s*(\([^()]*\))\s*\(;.*$\)_\1 \2\3_'
Make virtTestLoadFile allocate the buffer to read the file into.
Fix logic error in virtTestLoadFile, stop reading on the first empty line.
Use virFileReadLimFD in virtTestCaptureProgramOutput to avoid manual
buffer handling.
A few of the tests were missing basic sanity checks, while most
of them were doing copy-and-paste initialization (in fact, some
of them pasted the argc > 1 check more than once!). It's much
nicer to do things in one common place, and minimizes the size of
the next patch that fixes getcwd usage.
* tests/testutils.h (EXIT_AM_HARDFAIL): New define.
(progname, abs_srcdir): Define for all tests.
(VIRT_TEST_MAIN): Change callback signature.
* tests/testutils.c (virtTestMain): Do more common init.
* tests/commandtest.c (mymain): Simplify.
* tests/cputest.c (mymain): Likewise.
* tests/esxutilstest.c (mymain): Likewise.
* tests/eventtest.c (mymain): Likewise.
* tests/hashtest.c (mymain): Likewise.
* tests/networkxml2xmltest.c (mymain): Likewise.
* tests/nodedevxml2xmltest.c (myname): Likewise.
* tests/nodeinfotest.c (mymain): Likewise.
* tests/nwfilterxml2xmltest.c (mymain): Likewise.
* tests/qemuargv2xmltest.c (mymain): Likewise.
* tests/qemuhelptest.c (mymain): Likewise.
* tests/qemuxml2argvtest.c (mymain): Likewise.
* tests/qemuxml2xmltest.c (mymain): Likewise.
* tests/qparamtest.c (mymain): Likewise.
* tests/sexpr2xmltest.c (mymain): Likewise.
* tests/sockettest.c (mymain): Likewise.
* tests/statstest.c (mymain): Likewise.
* tests/storagepoolxml2xmltest.c (mymain): Likewise.
* tests/storagevolxml2xmltest.c (mymain): Likewise.
* tests/virbuftest.c (mymain): Likewise.
* tests/virshtest.c (mymain): Likewise.
* tests/vmx2xmltest.c (mymain): Likewise.
* tests/xencapstest.c (mymain): Likewise.
* tests/xmconfigtest.c (mymain): Likewise.
* tests/xml2sexprtest.c (mymain): Likewise.
* tests/xml2vmxtest.c (mymain): Likewise.
I wrote a patch to add support for listing the Vendor and Model of a
storage pool in the storage pool XML. This would allow vendor
extensions of specific devices. The patch includes a test for the new
attributes as well.
Patrick Dignan
The virConnectPtr is no longer required for error reporting since
that is recorded in a thread local. Remove use of virConnectPtr
from all APIs in storage_conf.{h,c} and storage_encryption_conf.{h,c}
and update all callers to match