Between reboots and kernel reloads, the SCSI host number used for SCSI
storage pools may change requiring modification to the storage pool XML
in order to use a specific SCSI host adapter.
This patch introduces the "parentaddr" element and "unique_id" attribute
for the SCSI host adapter in order to uniquely identify the adapter
between reboots and kernel reloads. For now the goal is to only parse
and format the XML. Both will be required to be provided in order to
uniquely identify the desired SCSI host.
The new XML is expected to be as follows:
<adapter type='scsi_host'>
<parentaddr unique_id='3'>
<address domain='0x0000' bus='0x00' slot='0x1f' func='0x2'/>
</parentaddr>
</adapter>
where "parentaddr" is the parent device of the SCSI host using the PCI
address on which the device resides and the value from the unique_id file
for the device. Both the PCI address and unique_id values will be used
to traverse the /sys/class/scsi_host/ directories looking at each link
to match the PCI address reformatted to the directory link format where
"domain🚌slot:function" is found. Then for each matching directory
the unique_id file for the scsi_host will be used to match the unique_id
value in the xml.
For a PCI address listed above, this will be formatted to "0000:00:1f.2"
and the links in /sys/class/scsi_host will be used to find the host#
to be used for the 'scsi_host' device. Each entry is a link to the
/sys/bus/pci/devices directories, e.g.:
% ls -al /sys/class/scsi_host/host2
lrwxrwxrwx. 1 root root 0 Jun 1 00:22 /sys/class/scsi_host/host2 -> ../../devices/pci0000:00/0000:00:1f.2/ata3/host2/scsi_host/host2
% cat /sys/class/scsi_host/host2/unique_id
3
The "parentaddr" and "name" attributes are mutually exclusive to identify
the SCSI host number. Use of the "parentaddr" element will be the preferred
mechanism.
This patch only supports to parse and format the XMLs. Later patches will
add code to find out the scsi host number.
Gluster volumes don't start with a leading slash. Our schema for netfs
gluster pools enforces it though. Luckily mount.glusterfs skips it.
Allow a slashless volume name for glusterfs netfs mounts in the schema.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1101999
Add support for a new <pool type='gluster'>, similar to
RBD and Sheepdog. Terminology wise, a gluster volume
forms a libvirt storage pool, within the gluster volume,
individual files are treated as libvirt storage volumes.
* docs/schemas/storagepool.rng (poolgluster): New pool type.
* docs/formatstorage.html.in: Document gluster.
* docs/storage.html.in: Likewise, and contrast it with netfs.
* tests/storagepoolxml2xmlin/pool-gluster.xml: New test.
* tests/storagepoolxml2xmlout/pool-gluster.xml: Likewise.
* tests/storagepoolxml2xmltest.c (mymain): Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
$ touch /var/lib/libvirt/images/'a<b>c'
$ virsh pool-refresh default
$ virsh vol-dumpxml 'a<b>c' default | head -n2
<volume>
<name>a<b>c</name>
Oops. That's not valid XML. And when we fix the XML
generation, it fails RelaxNG validation.
I'm also tired of seeing <key>(null)</key> in the example
output for volume xml; while we used NULLSTR() to avoid
a NULL deref rather than relying on glibc's printf
extension behavior, it's even better if we avoid the issue
in the first place. But this requires being careful that
we don't invalidate any storage backends that were relying
on key being unassigned during virStoragVolCreateXML[From].
I would have split this into two patches (one for escaping,
one for avoiding <key>(null)</key>), but since they both
end up touching a lot of the same test files, I ended up
merging it into one.
Note that this patch allows pretty much any volume name
that can appear in a directory (excluding . and .. because
those are special), but does nothing to change the current
(unenforced) RelaxNG claim that pool names will consist
only of letters, numbers, _, -, and +. Tightening the C
code to match RelaxNG patterns and/or relaxing the grammar
to match the C code for pool names is a task for another
day (but remember, we DID recently tighten C code for
domain names to exclude a leading '.').
* src/conf/storage_conf.c (virStoragePoolSourceFormat)
(virStoragePoolDefFormat, virStorageVolTargetDefFormat)
(virStorageVolDefFormat): Escape user-controlled strings.
(virStorageVolDefParseXML): Parse key, for use in unit tests.
* src/storage/storage_driver.c (storageVolCreateXML)
(storageVolCreateXMLFrom): Ensure parsed key doesn't confuse
volume creation.
* docs/schemas/basictypes.rng (volName): Relax definition.
* tests/storagepoolxml2xmltest.c (mymain): Test it.
* tests/storagevolxml2xmltest.c (mymain): Likewise.
* tests/storagepoolxml2xmlin/pool-dir-naming.xml: New file.
* tests/storagepoolxml2xmlout/pool-dir-naming.xml: Likewise.
* tests/storagevolxml2xmlin/vol-file-naming.xml: Likewise.
* tests/storagevolxml2xmlout/vol-file-naming.xml: Likewise.
* tests/storagevolxml2xmlout/vol-*.xml: Fix fallout.
Signed-off-by: Eric Blake <eblake@redhat.com>
While trying to compare netfs against my new gluster pool, I
discovered two things:
virt-xml-validate chokes on valid xml produced by 'virsh pool-dumpxml'
[yet another reason that ALL patches that add new xml should be adding
corresponding tests]
When using glusterfs FUSE mounts, you cannot access a subdirectory
of a gluster volume. The recommended workaround in the gluster
community is to mount the volume to an intermediate location, then
bind-mount the desired subdirectory to the final location. Maybe
we should teach libvirt to do bind-mounting, but for now I chose to
just document the limitation.
* docs/storage.html.in: Improve documentation.
* docs/schemas/storagepool.rng (sourcefmtnetfs): Allow all
formats, and drop redundant info-vendor.
* tests/storagepoolxml2xmltest.c (mymain): New test.
* tests/storagepoolxml2xmlin/pool-netfs-gluster.xml: New file.
* tests/storagepoolxml2xmlout/pool-netfs-gluster.xml: Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
The RNG grammar did not allow arbitrary interleaving, which makes
it harder than necessary to create a new pool from handwritten XML.
* docs/schemas/storagepool.rng: Allow interleaving.
* tests/storagepoolxml2xmlin/pool-sheepdog.xml: Test interleave.
* tests/storagepoolxml2xmlin/pool-iscsi-auth.xml: Likewise.
Signed-off-by: Eric Blake <eblake@redhat.com>
When using logical pools, we had to trust the target->path provided.
This parameter, however, can be completely ommited and we can use
'/dev/<source.name>' safely and populate it to target.path.
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=952973
The existing 'chap' XML logic was never used - just defined. Rather than
try to insert a square peg into a round hole, blow it up and rewrite the
logic to follow the 'ceph' format.
Remove the former "chap.login" and "chap.passwd" fields and replace
with "chap.username" and "chap.secret" in _virStoragePoolAuthChap.
Adjust the virStoragePoolDefParseAuthChap() to process.
Change the rng file to describe the new layout
Update the formatstorage.html to describe the usage of the secret element
to mention that the secret type "iscsi" and "ceph" can be used
to storage pool too.
Update the formatsecret.html to include a reference to the storage pool
Update tests to handle the changes from 'login' and 'passwd' to 'username'
and '<secret>' format
This introduces 4 new attributes for storage pool source adapter.
E.g.
<adapter type='fc_host' parent='scsi_host5' wwnn='20000000c9831b4b' wwpn='10000000c9831b4b'/>
Attribute 'type' can be either 'scsi_host' or 'fc_host', and defaults
to 'scsi_host' if attribute 'name' is specified. I.e. It's optional
for 'scsi_host' adapter, for back-compat reason. However, mandatory
for 'fc_host' adapter and any new future adapter types. Attribute
'parent' is to specify the parent for the fc_host adapter.
* docs/formatstorage.html.in:
- Add documents for the 4 new attrs
* docs/schemas/storagepool.rng:
- Add RNG schema
* src/conf/storage_conf.c:
- Parse and format the new XMLs
* src/conf/storage_conf.h:
- New struct virStoragePoolSourceAdapter, replace "char *adapter" with it;
- New enum virStoragePoolSourceAdapterType
* src/libvirt_private.syms:
- Export TypeToString and TypeFromString
* src/phyp/phyp_driver.c:
- Replace "adapter" with "adapter.data.name", which is member of the union
of the new struct virStoragePoolSourceAdapter now. Later patch will
add the checking, as "adapter.data.name" is only valid for "scsi_host"
adapter.
* src/storage/storage_backend_scsi.c:
- Like above
* tests/storagepoolxml2xmlin/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlin/pool-scsi-type-fc-host.xml:
- New test for 'fc_host' and "scsi_host" adapter
* tests/storagepoolxml2xmlout/pool-scsi.xml:
- Change the expected output, as the 'type' defaults to 'scsi_host' if 'name"
specified now
* tests/storagepoolxml2xmlout/pool-scsi-type-scsi-host.xml:
* tests/storagepoolxml2xmlout/pool-scsi-type-fc-host.xml:
- New test
* tests/storagepoolxml2xmltest.c:
- Include the test
capability.rng: Guest features can be in any order.
nodedev.rng: Added <driver> element, <capability> phys_function and
virt_functions for PCI devices.
storagepool.rng: Owner or group ID can be -1.
schema tests: New capabilities and nodedev files; changed owner and
group to -1 in pool-dir.xml.
storage_conf: Print uid_t and gid_t as signed to storage pool XML.
This patch brings support to manage sheepdog pools and volumes to libvirt.
It uses the "collie" command-line utility that comes with sheepdog for that.
A sheepdog pool in libvirt maps to a sheepdog cluster.
It needs a host and port to connect to, which in most cases
is just going to be the default of localhost on port 7000.
A sheepdog volume in libvirt maps to a sheepdog vdi.
To create one specify the pool, a name and the capacity.
Volumes can also be resized later.
In the volume XML the vdi name has to be put into the <target><path>.
To use the volume as a disk source for virtual machines specify
the vdi name as "name" attribute of the <source>.
The host and port information from the pool are specified inside the host tag.
<disk type='network'>
...
<source protocol="sheepdog" name="vdi_name">
<host name="localhost" port="7000"/>
</source>
</disk>
To work right this patch parses the output of collie,
so it relies on the raw output option. There recently was a bug which caused
size information to be reported wrong. This is fixed upstream already and
will be in the next release.
Signed-off-by: Sebastian Wiedenroth <wiedi@frubar.net>
This patch adds support for a new storage backend with RBD support.
RBD is the RADOS Block Device and is part of the Ceph distributed storage
system.
It comes in two flavours: Qemu-RBD and Kernel RBD, this storage backend only
supports Qemu-RBD, thus limiting the use of this storage driver to Qemu only.
To function this backend relies on librbd and librados being present on the
local system.
The backend also supports Cephx authentication for safe authentication with
the Ceph cluster.
For storing credentials it uses the built-in secret mechanism of libvirt.
Signed-off-by: Wido den Hollander <wido@widodh.nl>
I wrote a patch to add support for listing the Vendor and Model of a
storage pool in the storage pool XML. This would allow vendor
extensions of specific devices. The patch includes a test for the new
attributes as well.
Patrick Dignan
Spurious / in a pool target path makes life difficult for apps using the
GetVolByPath, and doing other path based comparisons with pools. This
has caused a few issues for virt-manager users:
https://bugzilla.redhat.com/show_bug.cgi?id=494005https://bugzilla.redhat.com/show_bug.cgi?id=593565
Add a new util API which removes spurious /, virFileSanitizePath. Sanitize
target paths when parsing pool XML, and for paths passed to GetVolByPath.
v2: Leading // must be preserved, properly sanitize path=/, sanitize
away /./ -> /
v3: Properly handle starting ./ and ending /.
v4: Drop all '.' handling, just sanitize / for now.