Previously libvirt would only add pci-bridge devices automatically
when an address was requested for a device that required a legacy PCI
slot and none was available. This patch expands that support to
dmi-to-pci-bridge (which is needed in order to add a pci-bridge on a
machine with a pcie-root), and pcie-root-port (which is needed to add
a hotpluggable PCIe device). It does *not* automatically add
pcie-switch-upstream-ports or pcie-switch-downstream-ports (and
currently there are no plans for that).
Given the existing code to auto-add pci-bridge devices, automatically
adding pcie-root-ports is fairly straightforward. The
dmi-to-pci-bridge support is a bit tricky though, for a few reasons:
1) Although the only reason to add a dmi-to-pci-bridge is so that
there is a reasonable place to plug in a pci-bridge controller,
most of the time it's not the presence of a pci-bridge *in the
config* that triggers the requirement to add a dmi-to-pci-bridge.
Rather, it is the presence of a legacy-PCI device in the config,
which triggers auto-add of a pci-bridge, which triggers auto-add of
a dmi-to-pci-bridge (this is handled in
virDomainPCIAddressSetGrow() - if there's a request to add a
pci-bridge we'll check if there is a suitable bus to plug it into;
if not, we first add a dmi-to-pci-bridge).
2) Once there is already a single dmi-to-pci-bridge on the system,
there won't be a need for any more, even if it's full, as long as
there is a pci-bridge with an open slot - you can also plug
pci-bridges into existing pci-bridges. So we have to make sure we
don't add a dmi-to-pci-bridge unless there aren't any
dmi-to-pci-bridges *or* any pci-bridges.
3) Although it is strongly discouraged, it is legal for a pci-bridge
to be directly plugged into pcie-root, and we don't want to
auto-add a dmi-to-pci-bridge if there is already a pci-bridge
that's been forced directly into pcie-root.
Although libvirt will now automatically create a dmi-to-pci-bridge
when it's needed, the code still remains for now that forces a
dmi-to-pci-bridge on all domains with pcie-root (in
qemuDomainDefAddDefaultDevices()). That will be removed in a future
patch.
For now, the pcie-root-ports are added one to a slot, which is a bit
wasteful and means it will fail after 31 total PCIe devices (30 if
there are also some PCI devices), but helps keep the changeset down
for this patch. A future patch will have 8 pcie-root-ports sharing the
functions on a single slot.
Andrea had the right idea when he disabled the "reserve an extra
unused slot" bit for aarch64/virt. For *any* PCI Express-based
machine, it is pointless since 1) an extra legacy-PCI slot can't be
used for hotplug, since hotplug into legacy PCI slots doesn't work on
PCI Express machinetypes, and 2) even for "coldplug" expansion,
everybody will want to expand using Express controllers, not legacy
PCI.
This patch eliminates the extra slot reserve unless the system has a
pci-root (i.e. legacy PCI)
The nec-usb-xhci device (which is a USB3 controller) has always
presented itself as a PCI device when plugged into a legacy PCI slot,
and a PCIe device when plugged into a PCIe slot, but libvirt has
always auto-assigned it to a legacy PCI slot.
This patch changes that behavior to auto-assign to a PCIe slot on
systems that have pcie-root (e.g. Q35 and aarch64/virt).
Since we don't yet auto-create pcie-*-port controllers on demand, this
means a config with an nec-xhci USB controller that has no PCI address
assigned will also need to have an otherwise-unused pcie-*-port
controller specified:
<controller type='pci' model='pcie-root-port'/>
<controller type='usb' model='nec-xhci'/>
(this assumes there is an otherwise-unused slot on pcie-root to accept
the pcie-root-port)
The e1000e is an emulated network device based on the Intel 82574,
present in qemu 2.7.0 and later. Among other differences from the
e1000, it presents itself as a PCIe device rather than legacy PCI. In
order to get it assigned to a PCIe controller, this patch updates the
flags setting for network devices when the model name is "e1000e".
(Note that for some reason libvirt has never validated the network
device model names other than to check that there are no dangerous
characters in them. That should probably change, but is the subject of
another patch.)
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1343094
libvirt previously assigned nearly all devices to a "hotpluggable"
legacy PCI slot even on machines with a PCIe root bus (and even though
most such machines don't even support hotplug on legacy PCI slots!)
Forcing all devices onto legacy PCI slots means that the domain will
need a dmi-to-pci-bridge (to convert from PCIe to legacy PCI) and a
pci-bridge (to provide hotpluggable legacy PCI slots which, again,
usually aren't hotpluggable anyway).
To help reduce the need for these legacy controllers, this patch tries
to assign virtio-1.0-capable devices to PCIe slots whenever possible,
by setting appropriate connectFlags in
virDomainCalculateDevicePCIConnectFlags(). Happily, when that function
was written (just a few commits ago) it was created with a
"virtioFlags" argument, set by both of its callers, which is the
proper connectFlags to set for any virtio-*-pci device - depending on
the arch/machinetype of the domain, and whether or not the qemu binary
supports virtio-1.0, that flag will have either been set to PCI or
PCIe. This patch merely enables the functionality by setting the flags
for the device to whatever is in virtioFlags if the device is a
virtio-*-pci device.
NB: the first virtio video device will be placed directly on bus 0
slot 1 rather than on a pcie-root-port due to the override for primary
video devices in qemuDomainValidateDevicePCISlotsQ35(). Whether or not
to change that is a topic of discussion, but this patch doesn't change
that particular behavior.
NB2: since the slot must be hotpluggable, and pcie-root (the PCIe root
complex) does *not* support hotplug, this means that suitable
controllers must also be in the config (i.e. either pcie-root-port, or
pcie-downstream-port). For now, libvirt doesn't add those
automatically, so if you put virtio devices in a config for a qemu
that has PCIe-capable virtio devices, you'll need to add extra
pcie-root-ports yourself. That requirement will be eliminated in a
future patch, but for now, it's simple to do this:
<controller type='pci' model='pcie-root-port'/>
<controller type='pci' model='pcie-root-port'/>
<controller type='pci' model='pcie-root-port'/>
...
Partially Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1330024
This patch cleans up the connect flags for certain types/models of
devices that aren't PCI to return 0. In the future that may be used as
an indicator to the caller about whether or not a device needs a PCI
address. For now it's just ignored, except for in
virDomainPCIAddressEnsureAddr() - called during device hotplug - (and
in some cases actually needs to be re-set to PCI|HOTPLUGGABLE just in
case someone (in some old config) has manually set a PCI address for a
device that isn't PCI.
Before now, all the qemu hotplug functions assumed that all devices to
be hotplugged were legacy PCI endpoint devices
(VIR_PCI_CONNECT_TYPE_PCI_DEVICE). This worked out "okay", because all
devices *are* legacy PCI endpoint devices on x86/440fx machinetypes,
and hotplug didn't work properly on machinetypes using PCIe anyway
(hotplugging onto a legacy PCI slot doesn't work, and until commit
b87703cf any attempt to manually specify a PCIe address for a
hotplugged device would be erroneously rejected).
This patch makes all qemu hotplug operations honor the pciConnectFlags
set by the single all-knowing function
qemuDomainDeviceCalculatePCIConnectFlags(). This is done in 3 steps,
but in a single commit since we would have to touch the other points
at each step anyway:
1) add a flags argument to the hypervisor-agnostic
virDomainPCIAddressEnsureAddr() (previously it hardcoded
..._PCI_DEVICE)
2) add a new qemu-specific function qemuDomainEnsurePCIAddress() which
gets the correct pciConnectFlags for the device from
qemuDomainDeviceConnectFlags(), then calls
virDomainPCIAddressEnsureAddr().
3) in qemu_hotplug.c replace all calls to
virDomainPCIAddressEnsureAddr() with calls to
qemuDomainEnsurePCIAddress()
So in effect, we're putting a "shim" on top of all calls to
virDomainPCIAddressEnsureAddr() that sets the right pciConnectFlags.
Set pciConnectFlags in each device's DeviceInfo and then use those
flags later when validating existing addresses in
qemuDomainCollectPCIAddress() and when assigning new addresses with
qemuDomainPCIAddressReserveNextAddr() (rather than scattering the
logic about which devices need which type of slot all over the place).
Note that the exact flags set by
qemuDomainDeviceCalculatePCIConnectFlags() are different from the
flags previously set manually in qemuDomainCollectPCIAddress(), but
this doesn't matter because all validation of addresses in that case
ignores the setting of the HOTPLUGGABLE flag, and treats PCIE_DEVICE
and PCI_DEVICE the same (this lax checking was done on purpose,
because there are some things that we want to allow the user to
specify manually, e.g. assigning a PCIe device to a PCI slot, that we
*don't* ever want libvirt to do automatically. The flag settings that
we *really* want to match are 1) the old flag settings in
qemuDomainAssignDevicePCISlots() (which is HOTPLUGGABLE | PCI_DEVICE
for everything except PCI controllers) and 2) the new flag settings
done by qemuDomainDeviceCalculatePCIConnectFlags() (which are
currently exactly that - HOTPLUGGABLE | PCI_DEVICE for everything
except PCI controllers).
The lowest level function of this trio
(qemuDomainDeviceCalculatePCIConnectFlags()) aims to be the single
authority for the virDomainPCIConnectFlags to use for any given device
using a particular arch/machinetype/qemu-binary.
qemuDomainFillDevicePCIConnectFlags() sets info->pciConnectFlags in a
single device (unless it has no virDomainDeviceInfo, in which case
it's a NOP).
qemuDomainFillAllPCIConnectFlags() sets info->pciConnectFlags in all
devices that have a virDomainDeviceInfo
The latter two functions aren't called anywhere yet. This commit is
just making them available. Later patches will replace all the current
hodge-podge of flag settings with calls to this single authority.
As with other devices assign the slot number right away when adding the
device. This will make the slot numbers static as we do with other
addressing elements and it will ultimately simplify allocation of the
alias in a static way which does not break with qemu.
When starting a new domain, we allocate the USB addresses and keep
an address cache in the domain object's private data.
However this data is lost on libvirtd restart.
Also generate the address cache if all the addresses have been
specified, so that devices hotplugged after libvirtd restart
also get theirs assigned.
https://bugzilla.redhat.com/show_bug.cgi?id=1387666
Commit 19a148b dropped the cache from QEMU's private domain object.
Assume the callers do not have the cache by default and use
a longer name for the internal ones that do.
This makes the shorter 'virDomainVirtioSerialAddrAutoAssign'
name availabe for a function that will not require the cache.
An upcoming commit will remove the "flag" argument from all the calls
to reserve the next available address|slot, but I don't want to change
the arguments in the hypervisor-agnostic
virDomainPCIAddressReserveNext*() functions, so this patch places a
simple qemu-specific wrapper around those functions - the new
functions don't take a flags arg, but grab it from the device's
info->pciConnectFlags.
More occurences of repeatedly dereferencing the same pointer stored in
an array are replaced with the definition of a temporary pointer that
is then used directly. No functional change.
All definition validation that doesn't depend on qemu capabilities
and was allowed previously as valid definition should be placed into
qemuDomainDefValidate.
The check whether video type is supported or not was based on an enum
that translates type into model. Use switch to ensure that if new
video type is added, it will be properly handled.
Signed-off-by: Pavel Hrdina <phrdina@redhat.com>
The 'multi' element in PCI address struct used as 'virTristateSwitch',
and its default value is 'VIR_TRISTATE_SWITCH_ABSENT'. Current PCI
process use 'false' to initialization 'multi', which is ambiguously
for assignment or comparison. This patch use '{0}' to initialize
the whole PCI address struct, which fix the 'multi' initialization
and makes code more simplify and explicitly.
Signed-off-by: Xian Han Yu <xhyubj@linux.vnet.ibm.com>
Dropping the caching of ccw address set.
The cached set is not required anymore, because the set is now being
recalculated from the domain definition on demand, so the cache
can be deleted.
The address sets (pci, ccw, virtio serial) are currently cached
in qemu private data, but all the information required to recreate
these sets is in the domain definition. Therefore I am removing
the redundant data and adding a way to recalculate these sets.
Add a function that calculates the ccw address set
from the domain definition.
Dropping the caching of virtio serial address set.
The cached set is not required anymore, because the set is now being
recalculated from the domain definition on demand, so the cache
can be deleted.
Credit goes to Cole Robinson.
The address sets (pci, ccw, virtio serial) are currently cached
in qemu private data, but all the information required to recreate
these sets is in the domain definition. Therefore I am removing
the redundant data and adding a way to recalculate these sets.
Add a function that calculates the virtio serial address set
from the domain definition.
Credit goes to Cole Robinson.
When parsing a command line with USB devices that have
no address specified, QEMU automatically adds a USB hub
if the device would fill up all the available USB ports.
To help most of the users, add one hub if there are more
USB devices than available ports. For wilder configurations,
expect the user to provide us with more hubs and/or controllers.
There has been some progress lately in enabling virtio-pci on
aarch64 guests; however, guest OS support is still spotty at best,
so most guests are going to be using virtio-mmio instead.
Currently, mach-virt guests are closely modeled after q35 guests,
and that includes always adding a dmi-to-pci-bridge that's just
impossible to get rid of. While that's acceptable (if suboptimal)
for q35, where you will always need some kind of PCI device anyway,
mach-virt guests should be allowed to avoid it.
Commit ff2126225d changed the error message to be more
detailed about the failure at hand; however, while the new
error message claims that "bus must be <= index", the error
message is displayed if "idx <= addr->bus", ie. when bus
is larger than or *equal to* index.
Change the error message to report the correct constraint,
and format it in a way that mirrors the check exactly to
make it clearer to people reading the code. The new error
message reads "index must be larger than bus".
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1339900
IS_USB2_CONTROLLER() is useful in more places aside from just when
assigning PCI addresses in QEMU, and is checking for enum values that
are all defined in conf/domain_conf.h anyway, so define it there
instead.
Based on some digital archaeology performed by jtomko, it's been determined
that the persistentAddrs variable is no longer necessary...
The variable was added by:
commit 141dea6bc7
CommitDate: 2010-02-12 17:25:52 +0000
Add persistence of PCI addresses to QEMU
Where it was set to 0 on domain startup if qemu did not support the
QEMUD_CMD_FLAG_DEVICE capability, to clear the addresses at shutdown,
because QEMU might make up different ones next time.
As of commit f5dd58a608
CommitDate: 2012-07-11 11:19:05 +0200
qemu: Extended qemuDomainAssignAddresses to be callable from
everywhere.
this was broken, when the persistentAddrs = 0 assignment was moved
inside qemuDomainAssignPCIAddresses and while it pretends to check
for !QEMU_CAPS_DEVICE, its parent qemuDomainAssignAddresses is only
called if QEMU_CAPS_DEVICE is present.
Since commit id '20a0fa8e' removed the QEMU_CAPS_DEVICE, Coverity notes
that it's no longer possible to have 'addrs' be NULL when checking for
a live domain since qemuDomainPCIAddressSetCreate would have jumped to
cleanup if addrs was NULL.
Rather than only assigning a PCI address when no address is given at
all, also do it when the config says that the address type is 'pci',
but it gives no address (virDeviceInfoPCIAddressWanted()).
There are also several places after parsing but prior to address
assignment where code previously expected that any info with address
type='pci' would have a *valid* PCI address, which isn't always the
case - now we check not only for type='pci', but also for a valid
address (virDeviceInfoPCIAddressPresent()).
The test case added in this patch was directly copied from Cole's patch titled:
qemu: Wire up address type=pci auto_allocate
All qemu versions we support have QEMU_CAPS_DEVICE, so checking
for it is redundant. Remove the usage.
The code diff isn't clear, but all that code is just inindented
with no other change.
Test cases that hit qemuDomainAssignAddresses but don't have
infrastructure for specifying qemuCaps values see lots of
churn, since now PCI addresses are in the XML output.
We do not need to propagate the exact return values
and the only possible ones are 0 and -1 anyway.
Remove the temporary variable and use the usual pattern:
if (f() < 0)
return -1;
We had both and the only difference was that the latter also included
information about multifunction setting. The problem with that was that
we couldn't use functions made for only one of the structs (e.g.
parsing). To consolidate those two structs, use the one in virpci.h,
include that in domain_conf.h and add the multifunction member in it.
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
This error message was too specific, based on the incorrect assumption
that any error was cause by auto-added bridges:
failed to create PCI bridge on bus 2: too many devices
with fixed addresses
In practice you can't know if a bridge with an index <= the bus it's
connecting to was added automatically, or if it was a mistake in
explicit config, and the auto-add problem is going to be dealt with in
a different way in an upcoming patch. The new message is this:
PCI Controller at index 1 (0x01) has "
bus='0x02', but bus must be <= index
(note that index is given in both decimal and hex because it is
formatted as decimal in the XML, but bus is formatted as hex, and
displaying the hex value of index makes it easier to see the problem
when index > 9 (which will often be the case with PCIe, since most
controllers only have a single port, not 32 slots as with standard
PCI)).
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1004593
This is backed by the qemu device pxb-pcie, which will be available in
qemu 2.6.0.
As with pci-expander-bus (which uses qemu's pxb device), the busNr
attribute and <node> subelement of <target> are used to set the bus_nr
and numa_node options.
During post-parse we validate that the domain's machinetype is
q35-based (since the device shows up for 440fx-based machinetypes, but
is unusable), as well as checking that <node> specifies a node that is
actually configured on the guest.
This controller provides a single PCIe port on a new root. It is
similar to pci-expander-bus, intended to provide a bus that can be
associated with a guest-identifiable NUMA node, but is for
machinetypes with PCIe rather than PCI (e.g. q35-based machinetypes).
Aside from PCIe vs. PCI, the other main difference is that a
pci-expander-bus has a companion pci-bridge that is automatically
attached along with it, but pcie-expander-bus has only a single port,
and that port will only connect to a pcie-root-port, or to a
pcie-switch-upstream-port. In order for the bus to be of any use in
the guest, it must have either a pcie-root-port or a
pcie-switch-upstream-port attached (and one or more
pcie-switch-downstream-ports attached to the
pcie-switch-upstream-port).
This is backed by the qemu device "pxb".
The pxb device always includes a pci-bridge that is at the bus number
of the pxb + 1.
busNr and <node> from the <target> subelement are used to set the
bus_nr and numa_node options for pxb.
During post-parse we validate that the domain's machinetype is
440fx-based (since the pxb device only works on 440fx-based machines),
and <node> also gets a sanity check to assure that the NUMA node
specified for the pxb (if any - it's optional) actually exists on the
guest.
This is a standard PCI root bus (not a bridge) that can be added to a
440fx-based domain. Although it uses a PCI slot, this is *not* how it
is connected into the PCI bus hierarchy, but is only used for
control. Each pci-expander-bus provides 32 slots (0-31) that can
accept hotplug of standard PCI devices.
The usefulness of pci-expander-bus relative to a pci-bridge is that
the NUMA node of the bus can be specified with the <node> subelement
of <target>. This gives guest-side visibility to the NUMA node of
attached devices (presuming that management apps only assign a device
to a bus that has a NUMA node number matching the node number of the
device on the host).
Each pci-expander-bus also has a "busNr" attribute. The expander-bus
itself will take the busNr specified, and all buses that are connected
to this bus (including the pci-bridge that is automatically added to
any expander bus of model "pxb" (see the next commit)) will use
busNr+1, busNr+2, etc, and the pci-root (or the expander-bus with next
lower busNr) will use bus numbers lower than busNr.
There are two places in qemu_domain_address.c where we have a switch
statement to convert PCI controller models
(VIR_DOMAIN_CONTROLLER_MODEL_PCI*) into the connection type flag that
is matched when looking for an upstream connection for that model of
controller (VIR_PCI_CONNECT_TYPE_*). This patch makes a utility
function in conf/domain_addr.c to do that, so that when a new PCI
controller is added, we only need to add the new model-->connect-type
in a single place.
The flags used to determine which devices could be plugged into which
controllers were quite confusing, as they tried to create classes of
connections, then put particular devices into possibly multiple
classes, while sometimes setting multiple flags for the controllers
themselves. The attempt to have a single flag indicate, e.g. that a
root-port or a switch-downstream-port could connect was not only
confusing, it was leading to a situation where it would be impossible
to specify exactly the right combinations for a new controller.
The solution is for the VIR_PCI_CONNECT_TYPE_* flags to have a 1:1
correspondence with each type of PCI controller, plus a flag for a PCI
endpoint device and another for a PCIe endpoint device (the only
exception to this is that pci-bridge and pcie-expander-bus controllers
have their upstream connection classified as
VIR_PCI_CONNECT_TYPE_PCI_DEVICE since they can be plugged into
*exactly* the same ports as any endpoint device). Each device then
has a single flag for connect type (plus the HOTPLUG flag if that
device can e hotplugged), and each controller sets the CONNECT bits
for all controllers that can be plugged into it, as well as for either
type of endpoint device that can be plugged in (and the HOTPLUG flag
if it can accept hotplugged devices).
With this change, it is *slightly* easier to understand the matching
of connections (as long as you remember that the flag for a
device/upstream-facing connection of a controller is the same as that
device's type, while the flags for a controller's downstream
connections is the OR of all device types that can be plugged into
that controller). More importantly, it will be possible to correctly
specify what can be plugged into a pcie-switch-expander-bus, when
support for it is added.
Add new function to manage adding the controller -device options to the
command line removing that task from the mainline qemuBuildCommandLine.
Also adjust to using const virDomainDef instead of virDomainDefPtr.
This causes collateral damage in order to modify called APIs to use
the const virDomainDef instead as well.
Signed-off-by: John Ferlan <jferlan@redhat.com>
This does nothing more than adding the new device and capability.
The device is present since QEMU 2.6.0.
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Create new modules qemu_domain_address.c and qemu_domain_address.h to
contain all the new functions and header data. Additionally move any
supporting static functions.
Make qemuDomainSupportsPCI non static.
Also, move and rename the following:
qemuSetSCSIControllerModel to qemuDomainSetSCSIControllerModel
qemuCollectPCIAddress to qemuDomainCollectPCIAddress
qemuValidateDevicePCISlotsPIIX3 to qemuDomainValidateDevicePCISlotsPIIX3
qemuAssignDevicePCISlots to qemuDomainAssignDevicePCISlots
Signed-off-by: John Ferlan <jferlan@redhat.com>