Commit Graph

556 Commits

Author SHA1 Message Date
Sebastien Boeuf
86bc313f38 virtio-devices, vmm: Register a DMA handler to VirtioPciDevice
Given that some virtio device might need some DMA handling, we provide a
way to store this through the VirtioPciDevice layer, so that it can be
accessed when the PCI device is removed.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-03-11 12:37:17 +01:00
Sebastien Boeuf
54d63e774c vmm: device_manager: Extend MetaVirtioDevice with a DMA handler
In anticipation for handling potential DMA mapping/unmapping operations for a
virtio device, we extend the MetaVirtioDevice with an additional field
that holds an optional DMA handler.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-03-11 12:37:17 +01:00
Sebastien Boeuf
f801b0fc72 vmm: device_manager: Factorize virtio device tuple into structure
The tuple of information related to each virtio device is too big, and
it's better to factorize it through a dedicated structure.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-03-11 12:37:17 +01:00
Sebastien Boeuf
80296b9497 vmm: device_manager: Remove typedef VirtioDeviceArc
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-03-11 12:37:17 +01:00
Wei Liu
4cf22e4ec7 arch: do not hardcode MMIO region length in MmioDeviceInfo
Add a field for its length and fix up users.

Things work just because all hardcoded values agree with each other.
This is prone to breakage.

No functional change.

Signed-off-by: Wei Liu <liuwe@microsoft.com>
2022-03-04 15:21:48 +08:00
Sebastien Boeuf
42b5d4a2f7 pci, vmm: Update DeviceNode to store PciBdf instead of u32
By having the DeviceNode storing a PciBdf, we simplify the internal code
as well as allow for custom Serialize/Deserialize implementation for the
PciBdf structure. These custom implementations let us display the PCI
s/b/d/f in a human readable format.

Fixes #3711

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-02-16 11:57:23 +00:00
Rob Bradford
20b9f95afd vmm: Attach all devices from specified segments to the IOMMU
Since the devices behind the IOMMU cannot be changed at runtime we offer
the ability to place all devices on user chosen segments behind the
IOMMU. This allows the hotplugging of devices behind the IOMMU provided
that they are assigned to a segment that is located behind the iommu.

Fixes: #911

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2022-02-11 11:20:04 +00:00
Sebastien Boeuf
052f38fa96 vmm: Enable guest to report free pages through virtio-balloon
Adding a new parameter free_page_reporting=on|off to the balloon device
so that we can enable the corresponding feature from virtio-balloon.

Running a VM with a balloon device where this feature is enabled allows
the guest to report pages that are free from guest's perspective. This
information is used by the VMM to release the corresponding pages on the
host.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-02-11 12:10:07 +01:00
lizhaoxin1
a45e458c50 vm-migration: Add start_migration() to Migratable trait
In order to clearly decouple when the migration is started compared to
when the dirty logging is started, we introduce a new method to the
Migratable trait. This clarifies the semantics as we don't end up using
start_dirty_log() for identifying when the migration has been started.
And similarly, we rely on the already existing complete_migration()
method to know when the migration has been ended.

A bug was reported when running a local migration with a vhost-user-net
device in server mode. The reason was because the migration_started
variable was never set to "true", since the start_dirty_log() function
was never invoked.

Signed-off-by: lizhaoxin1 <Lxiaoyouling@163.com>
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-02-03 13:33:26 +01:00
Sebastien Boeuf
8eed276d14 vm-virtio: Define AccessPlatform trait
Moving the whole codebase to rely on the AccessPlatform definition from
vm-virtio so that we can fully remove it from virtio-queue crate.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2022-01-27 10:00:20 +00:00
Anatol Belski
e2a8a1483f acpi: aarch64: Implement DBG2 table
This table is listed as required in the ARM Base Boot Requirements
document. The particular need arises to make the serial debugging of
Windows guest functional.

Signed-off-by: Anatol Belski <anbelski@linux.microsoft.com>
2022-01-20 09:11:21 +08:00
Michael Zhao
1db7718589 pci, vmm: Pass PCI BDF to vfio and vfio_user
On AArch64, PCI BDF is used for devId in MSI-X routing entry.

Signed-off-by: Michael Zhao <michael.zhao@arm.com>
2022-01-18 18:00:00 -08:00
Wei Liu
277cfd07ba device_manager: use if let to drop single match
Signed-off-by: Wei Liu <liuwe@microsoft.com>
2022-01-18 17:23:27 -08:00
Rob Bradford
9ef1187f4a vmm, pci: Fix potential deadlock in PCI BAR allocation
The allocator is locked by both the BAR allocation code and the
interrupt allocation code. Resulting in a potential lock inversion
error.

WARNING: ThreadSanitizer: lock-order-inversion (potential deadlock) (pid=26318)
  Cycle in lock order graph: M87 (0x7b0c00001e30) => M28 (0x7b0c00001830) => M87

  Mutex M28 acquired here while holding mutex M87 in thread T1:
    #0 pthread_mutex_lock /rustc/llvm/src/llvm-project/compiler-rt/lib/tsan/../sanitizer_common/sanitizer_common_interceptors.inc:4249:3 (cloud-hypervisor+0x9c368)
    #1 std::sys::unix::mutex::Mutex:🔒:hcd1b9aa06ff775d3 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/mutex.rs:63:17 (cloud-hypervisor+0x663954)
    #2 std::sys_common::mutex::MovableMutex::raw_lock::hff98d0b036469bca /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/mutex.rs:76:18 (cloud-hypervisor+0x491bae)
    #3 std::sync::mutex::Mutex$LT$T$GT$:🔒:hc61622e5536f5b72 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sync/mutex.rs:267:13 (cloud-hypervisor+0x36d07b)
    #4 _$LT$vmm..interrupt..MsiInterruptManager$LT$kvm_bindings..x86..bindings..kvm_irq_routing_entry$GT$$u20$as$u20$vm_device..interrupt..InterruptManager$GT$::create_group::hd412b5e1e8eeacc2 /home/rob/src/cloud-hypervisor/vmm/src/interrupt.rs:310:29 (cloud-hypervisor+0x6d1403)
    #5 virtio_devices::transport::pci_device::VirtioPciDevice:🆕:h3af603c3f00f4b3d /home/rob/src/cloud-hypervisor/virtio-devices/src/transport/pci_device.rs:376:38 (cloud-hypervisor+0x8e6137)
    #6 vmm::device_manager::DeviceManager::add_virtio_pci_device::h23608151d7668a1c /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:3333:37 (cloud-hypervisor+0x3b6339)
    #7 vmm::device_manager::DeviceManager::add_pci_devices::h136cc20cbeb6b977 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1236:30 (cloud-hypervisor+0x390aad)
    #8 vmm::device_manager::DeviceManager::create_devices::h29fc5b8a20e1aea5 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1155:9 (cloud-hypervisor+0x38f48c)
    #9 vmm::vm::Vm:🆕:h43efe7c6cd97ede5 /home/rob/src/cloud-hypervisor/vmm/src/vm.rs:799:9 (cloud-hypervisor+0x334641)
    #10 vmm::Vmm::vm_boot::h06bdf54b95d5e14f /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:379:26 (cloud-hypervisor+0x2e5ba8)
    #11 vmm::Vmm::control_loop::h40c9b48c7b800bed /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:1299:48 (cloud-hypervisor+0x2f44e0)
    #12 vmm::start_vmm_thread::_$u7b$$u7b$closure$u7d$$u7d$::h016d2f7cff698175 /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:263:17 (cloud-hypervisor+0x1dda20)
    #13 std::sys_common::backtrace::__rust_begin_short_backtrace::h7fd2df3e7cfba503 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/backtrace.rs:123:18 (cloud-hypervisor+0x659bca)
    #14 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::_$u7b$$u7b$closure$u7d$$u7d$::h89880b05fe892d7e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:477:17 (cloud-hypervisor+0x44100e)
    #15 _$LT$core..panic..unwind_safe..AssertUnwindSafe$LT$F$GT$$u20$as$u20$core..ops..function..FnOnce$LT$$LP$$RP$$GT$$GT$::call_once::h487382524d80571f /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/panic/unwind_safe.rs:271:9 (cloud-hypervisor+0x6dda5e)
    #16 std::panicking::try::do_call::h1d9c2ccdc39f3322 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:406:40 (cloud-hypervisor+0x6d36d1)
    #17 __rust_try 3hkmq3dzyyv5ejsx (cloud-hypervisor+0x6d4718)
    #18 std::panicking::try::h251306df23d21913 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:370:19 (cloud-hypervisor+0x6d2459)
    #19 std::panic::catch_unwind::h2a9ac2fb12c3c64e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panic.rs:133:14 (cloud-hypervisor+0x57bdce)
    #20 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::h10f4c340611b55e4 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:476:30 (cloud-hypervisor+0x43f913)
    #21 core::ops::function::FnOnce::call_once$u7b$$u7b$vtable.shim$u7d$$u7d$::hdd9b37241caf97b3 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/ops/function.rs:227:5 (cloud-hypervisor+0x3cf3f5)
    #22 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::ha5022a6bb7833f62 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #23 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::h481697829cbc6746 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #24 std::sys::unix:🧵:Thread:🆕:thread_start::h6fad62c4c393bbe7 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/thread.rs:108:17 (cloud-hypervisor+0x119d492)

  Mutex M87 previously acquired by the same thread here:
    #0 pthread_mutex_lock /rustc/llvm/src/llvm-project/compiler-rt/lib/tsan/../sanitizer_common/sanitizer_common_interceptors.inc:4249:3 (cloud-hypervisor+0x9c368)
    #1 std::sys::unix::mutex::Mutex:🔒:h9a2d3e97e05c6430 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/mutex.rs:63:17 (cloud-hypervisor+0x9ea344)
    #2 std::sys_common::mutex::MovableMutex::raw_lock::h8abb3b5cf55c0264 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/mutex.rs:76:18 (cloud-hypervisor+0x96face)
    #3 std::sync::mutex::Mutex$LT$T$GT$:🔒:hecec128d40c6dd44 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sync/mutex.rs:267:13 (cloud-hypervisor+0x97120a)
    #4 virtio_devices::transport::pci_device::VirtioPciDevice:🆕:h3af603c3f00f4b3d /home/rob/src/cloud-hypervisor/virtio-devices/src/transport/pci_device.rs:356:29 (cloud-hypervisor+0x8e5c0e)
    #5 vmm::device_manager::DeviceManager::add_virtio_pci_device::h23608151d7668a1c /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:3333:37 (cloud-hypervisor+0x3b6339)
    #6 vmm::device_manager::DeviceManager::add_pci_devices::h136cc20cbeb6b977 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1236:30 (cloud-hypervisor+0x390aad)
    #7 vmm::device_manager::DeviceManager::create_devices::h29fc5b8a20e1aea5 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1155:9 (cloud-hypervisor+0x38f48c)
    #8 vmm::vm::Vm:🆕:h43efe7c6cd97ede5 /home/rob/src/cloud-hypervisor/vmm/src/vm.rs:799:9 (cloud-hypervisor+0x334641)
    #9 vmm::Vmm::vm_boot::h06bdf54b95d5e14f /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:379:26 (cloud-hypervisor+0x2e5ba8)
    #10 vmm::Vmm::control_loop::h40c9b48c7b800bed /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:1299:48 (cloud-hypervisor+0x2f44e0)
    #11 vmm::start_vmm_thread::_$u7b$$u7b$closure$u7d$$u7d$::h016d2f7cff698175 /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:263:17 (cloud-hypervisor+0x1dda20)
    #12 std::sys_common::backtrace::__rust_begin_short_backtrace::h7fd2df3e7cfba503 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/backtrace.rs:123:18 (cloud-hypervisor+0x659bca)
    #13 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::_$u7b$$u7b$closure$u7d$$u7d$::h89880b05fe892d7e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:477:17 (cloud-hypervisor+0x44100e)
    #14 _$LT$core..panic..unwind_safe..AssertUnwindSafe$LT$F$GT$$u20$as$u20$core..ops..function..FnOnce$LT$$LP$$RP$$GT$$GT$::call_once::h487382524d80571f /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/panic/unwind_safe.rs:271:9 (cloud-hypervisor+0x6dda5e)
    #15 std::panicking::try::do_call::h1d9c2ccdc39f3322 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:406:40 (cloud-hypervisor+0x6d36d1)
    #16 __rust_try 3hkmq3dzyyv5ejsx (cloud-hypervisor+0x6d4718)
    #17 std::panicking::try::h251306df23d21913 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:370:19 (cloud-hypervisor+0x6d2459)
    #18 std::panic::catch_unwind::h2a9ac2fb12c3c64e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panic.rs:133:14 (cloud-hypervisor+0x57bdce)
    #19 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::h10f4c340611b55e4 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:476:30 (cloud-hypervisor+0x43f913)
    #20 core::ops::function::FnOnce::call_once$u7b$$u7b$vtable.shim$u7d$$u7d$::hdd9b37241caf97b3 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/ops/function.rs:227:5 (cloud-hypervisor+0x3cf3f5)
    #21 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::ha5022a6bb7833f62 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #22 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::h481697829cbc6746 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #23 std::sys::unix:🧵:Thread:🆕:thread_start::h6fad62c4c393bbe7 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/thread.rs:108:17 (cloud-hypervisor+0x119d492)

  Mutex M87 acquired here while holding mutex M28 in thread T1:
    #0 pthread_mutex_lock /rustc/llvm/src/llvm-project/compiler-rt/lib/tsan/../sanitizer_common/sanitizer_common_interceptors.inc:4249:3 (cloud-hypervisor+0x9c368)
    #1 std::sys::unix::mutex::Mutex:🔒:h9a2d3e97e05c6430 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/mutex.rs:63:17 (cloud-hypervisor+0x9ea344)
    #2 std::sys_common::mutex::MovableMutex::raw_lock::h8abb3b5cf55c0264 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/mutex.rs:76:18 (cloud-hypervisor+0x96face)
    #3 std::sync::mutex::Mutex$LT$T$GT$:🔒:hecec128d40c6dd44 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sync/mutex.rs:267:13 (cloud-hypervisor+0x97120a)
    #4 _$LT$virtio_devices..transport..pci_device..VirtioPciDevice$u20$as$u20$pci..device..PciDevice$GT$::allocate_bars::h39dc42b48fc8264c /home/rob/src/cloud-hypervisor/virtio-devices/src/transport/pci_device.rs:850:22 (cloud-hypervisor+0x8eb1a4)
    #5 vmm::device_manager::DeviceManager::add_pci_device::h561f6c8ed61db117 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:3087:20 (cloud-hypervisor+0x3b0c62)
    #6 vmm::device_manager::DeviceManager::add_virtio_pci_device::h23608151d7668a1c /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:3359:20 (cloud-hypervisor+0x3b6707)
    #7 vmm::device_manager::DeviceManager::add_pci_devices::h136cc20cbeb6b977 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1236:30 (cloud-hypervisor+0x390aad)
    #8 vmm::device_manager::DeviceManager::create_devices::h29fc5b8a20e1aea5 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1155:9 (cloud-hypervisor+0x38f48c)
    #9 vmm::vm::Vm:🆕:h43efe7c6cd97ede5 /home/rob/src/cloud-hypervisor/vmm/src/vm.rs:799:9 (cloud-hypervisor+0x334641)
    #10 vmm::Vmm::vm_boot::h06bdf54b95d5e14f /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:379:26 (cloud-hypervisor+0x2e5ba8)
    #11 vmm::Vmm::control_loop::h40c9b48c7b800bed /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:1299:48 (cloud-hypervisor+0x2f44e0)
    #12 vmm::start_vmm_thread::_$u7b$$u7b$closure$u7d$$u7d$::h016d2f7cff698175 /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:263:17 (cloud-hypervisor+0x1dda20)
    #13 std::sys_common::backtrace::__rust_begin_short_backtrace::h7fd2df3e7cfba503 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/backtrace.rs:123:18 (cloud-hypervisor+0x659bca)
    #14 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::_$u7b$$u7b$closure$u7d$$u7d$::h89880b05fe892d7e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:477:17 (cloud-hypervisor+0x44100e)
    #15 _$LT$core..panic..unwind_safe..AssertUnwindSafe$LT$F$GT$$u20$as$u20$core..ops..function..FnOnce$LT$$LP$$RP$$GT$$GT$::call_once::h487382524d80571f /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/panic/unwind_safe.rs:271:9 (cloud-hypervisor+0x6dda5e)
    #16 std::panicking::try::do_call::h1d9c2ccdc39f3322 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:406:40 (cloud-hypervisor+0x6d36d1)
    #17 __rust_try 3hkmq3dzyyv5ejsx (cloud-hypervisor+0x6d4718)
    #18 std::panicking::try::h251306df23d21913 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:370:19 (cloud-hypervisor+0x6d2459)
    #19 std::panic::catch_unwind::h2a9ac2fb12c3c64e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panic.rs:133:14 (cloud-hypervisor+0x57bdce)
    #20 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::h10f4c340611b55e4 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:476:30 (cloud-hypervisor+0x43f913)
    #21 core::ops::function::FnOnce::call_once$u7b$$u7b$vtable.shim$u7d$$u7d$::hdd9b37241caf97b3 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/ops/function.rs:227:5 (cloud-hypervisor+0x3cf3f5)
    #22 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::ha5022a6bb7833f62 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #23 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::h481697829cbc6746 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #24 std::sys::unix:🧵:Thread:🆕:thread_start::h6fad62c4c393bbe7 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/thread.rs:108:17 (cloud-hypervisor+0x119d492)

  Mutex M28 previously acquired by the same thread here:
    #0 pthread_mutex_lock /rustc/llvm/src/llvm-project/compiler-rt/lib/tsan/../sanitizer_common/sanitizer_common_interceptors.inc:4249:3 (cloud-hypervisor+0x9c368)
    #1 std::sys::unix::mutex::Mutex:🔒:hcd1b9aa06ff775d3 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/mutex.rs:63:17 (cloud-hypervisor+0x663954)
    #2 std::sys_common::mutex::MovableMutex::raw_lock::hff98d0b036469bca /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/mutex.rs:76:18 (cloud-hypervisor+0x491bae)
    #3 std::sync::mutex::Mutex$LT$T$GT$:🔒:hc61622e5536f5b72 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sync/mutex.rs:267:13 (cloud-hypervisor+0x36d07b)
    #4 vmm::device_manager::DeviceManager::add_pci_device::h561f6c8ed61db117 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:3091:22 (cloud-hypervisor+0x3b0a95)
    #5 vmm::device_manager::DeviceManager::add_virtio_pci_device::h23608151d7668a1c /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:3359:20 (cloud-hypervisor+0x3b6707)
    #6 vmm::device_manager::DeviceManager::add_pci_devices::h136cc20cbeb6b977 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1236:30 (cloud-hypervisor+0x390aad)
    #7 vmm::device_manager::DeviceManager::create_devices::h29fc5b8a20e1aea5 /home/rob/src/cloud-hypervisor/vmm/src/device_manager.rs:1155:9 (cloud-hypervisor+0x38f48c)
    #8 vmm::vm::Vm:🆕:h43efe7c6cd97ede5 /home/rob/src/cloud-hypervisor/vmm/src/vm.rs:799:9 (cloud-hypervisor+0x334641)
    #9 vmm::Vmm::vm_boot::h06bdf54b95d5e14f /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:379:26 (cloud-hypervisor+0x2e5ba8)
    #10 vmm::Vmm::control_loop::h40c9b48c7b800bed /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:1299:48 (cloud-hypervisor+0x2f44e0)
    #11 vmm::start_vmm_thread::_$u7b$$u7b$closure$u7d$$u7d$::h016d2f7cff698175 /home/rob/src/cloud-hypervisor/vmm/src/lib.rs:263:17 (cloud-hypervisor+0x1dda20)
    #12 std::sys_common::backtrace::__rust_begin_short_backtrace::h7fd2df3e7cfba503 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys_common/backtrace.rs:123:18 (cloud-hypervisor+0x659bca)
    #13 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::_$u7b$$u7b$closure$u7d$$u7d$::h89880b05fe892d7e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:477:17 (cloud-hypervisor+0x44100e)
    #14 _$LT$core..panic..unwind_safe..AssertUnwindSafe$LT$F$GT$$u20$as$u20$core..ops..function..FnOnce$LT$$LP$$RP$$GT$$GT$::call_once::h487382524d80571f /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/panic/unwind_safe.rs:271:9 (cloud-hypervisor+0x6dda5e)
    #15 std::panicking::try::do_call::h1d9c2ccdc39f3322 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:406:40 (cloud-hypervisor+0x6d36d1)
    #16 __rust_try 3hkmq3dzyyv5ejsx (cloud-hypervisor+0x6d4718)
    #17 std::panicking::try::h251306df23d21913 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panicking.rs:370:19 (cloud-hypervisor+0x6d2459)
    #18 std::panic::catch_unwind::h2a9ac2fb12c3c64e /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/panic.rs:133:14 (cloud-hypervisor+0x57bdce)
    #19 std:🧵:Builder::spawn_unchecked::_$u7b$$u7b$closure$u7d$$u7d$::h10f4c340611b55e4 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/thread/mod.rs:476:30 (cloud-hypervisor+0x43f913)
    #20 core::ops::function::FnOnce::call_once$u7b$$u7b$vtable.shim$u7d$$u7d$::hdd9b37241caf97b3 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/core/src/ops/function.rs:227:5 (cloud-hypervisor+0x3cf3f5)
    #21 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::ha5022a6bb7833f62 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #22 _$LT$alloc..boxed..Box$LT$F$C$A$GT$$u20$as$u20$core..ops..function..FnOnce$LT$Args$GT$$GT$::call_once::h481697829cbc6746 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/alloc/src/boxed.rs:1854:9 (cloud-hypervisor+0x119d492)
    #23 std::sys::unix:🧵:Thread:🆕:thread_start::h6fad62c4c393bbe7 /rustc/7d6f948173ccb18822bab13d548c65632db5f0aa/library/std/src/sys/unix/thread.rs:108:17 (cloud-hypervisor+0x119d492)

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2022-01-06 09:59:36 +01:00
Rob Bradford
a749063c8a vmm: Don't assume that resize_pipe is initialised
If the underlying kernel is old PTY resize is disabled and this is
represented by the use of None in the provided Option<File> type. In the
virtio-console PTY path don't blindly unwrap() the value that will be
preserved across a reboot.

Fixes: #3496

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2022-01-04 12:04:50 +00:00
Rob Bradford
afe386bc13 vmm: Only warn on error when setting up SIGWINCH handler
Setting up the SIGWINCH handler requires at least Linux 5.7. However
this functionality is not required for basic PTY operation.

Fixes: #3456

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-12-14 13:05:09 +01:00
Rob Bradford
50f5f43ae3 vmm: acpi: Make MBRD _CRS multi-segment aware
Advertise the PCI MMIO config spaces here so that the MMIO config space
is correctly recognised.

Tested by: --platform num_pci_segments=1 or 16 hotplug NVMe vfio-user device
works correctly with hypervisor-fw & OVMF and direct kernel boot.

Fixes: #3432

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-12-08 14:38:30 +00:00
Rob Bradford
e1c09b66ba vmm: Replace device tree value when restoring DeviceManager
When restoring replace the internal value of the device tree rather than
replacing the Arc<Mutex<DeviceTree>> itself. This is fixes an issue
where the AddressManager has a copy of the the original
Arc<Mutex<DeviceTree>> from when the DeviceManager was created. The
original restore path only replaced the DeviceManager's version of the
Arc<Mutex<DeviceTree>>. Instead replace the contents of the
Arc<Mutex<DeviceTree>> so all users see the updated version.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-12-06 15:58:37 +00:00
Henry Wang
07bef815cc aarch64: Introduce struct PciSpaceInfo for FDT
Currently, a tuple containing PCI space start address and PCI space
size is used to pass the PCI space information to the FDT creator.
In order to support the multiple PCI segment for FDT, more information
such as the PCI segment ID should be passed to the FDT creator. If we
still use a tuple to store these information, the code flexibility and
readablity will be harmed.

To address this issue, this commit replaces the tuple containing the
PCI space information to a structure `PciSpaceInfo` and uses a vector
of `PciSpaceInfo` to store PCI space information for each segment, so
that multiple PCI segment information can be passed to the FDT together.

Note that the scope of this commit will only contain the refactor of
original code, the actual multiple PCI segments support will be in
following series, and for now `--platform num_pci_segments` should only
be 1.

Signed-off-by: Henry Wang <Henry.Wang@arm.com>
2021-12-06 09:29:49 +00:00
Ziye Yang
51cfffd24f vmm: Make the comments consistent in 'DeviceManager'
Change  "Failed xxing" to "Failed to xx", then
we can only we one style.

Signed-off-by: Ziye Yang <ziye.yang@intel.com>
2021-11-19 08:43:23 +00:00
Bo Chen
2a312cd4fe vmm: Fix a comment typo from 'DeviceManager'
Signed-off-by: Bo Chen <chen.bo@intel.com>
2021-11-18 12:00:39 -08:00
Wei Liu
9b3cab8c72 device_manager: check return value of dup(2)
That function call can return -1 when it fails. Wrapping -1 into File
causes the code to panic when the File is dropped.

Signed-off-by: Wei Liu <liuwe@microsoft.com>
2021-11-17 23:12:11 +00:00
Wei Liu
84630aa0b5 device_manager: provide a few safety comments
Signed-off-by: Wei Liu <liuwe@microsoft.com>
2021-11-17 23:12:11 +00:00
Alyssa Ross
ad8ed80eb1 vmm: use the tty raw mode implementation from libc
I encountered some trouble trying to use a virtio-console hooked up to
a PTY.  Reading from the PTY would produce stuff like this
"\n\nsh-5.1# \n\nsh-5.1# " (where I'm just pressing enter at a shell
prompt), and a terminal would render that like this:

----------------------------------------------------------------

sh-5.1#

       sh-5.1#
----------------------------------------------------------------

This was because we weren't disabling the ICRNL termios iflag, which
turns carriage returns (\r) into line feeds (\n).  Other raw mode
implementations (like QEMU's) set this flag, and don't have this
problem.

Instead of fixing our raw mode implementation to just disable ICRNL,
or copy the flags from QEMU's, though, here I've changed it to use the
raw mode implementation in libc.  It seems to work correctly in my
testing, and means we don't have to worry about what exactly raw mode
looks like under the hood any more.

Signed-off-by: Alyssa Ross <hi@alyssa.is>
2021-11-17 14:41:00 +00:00
Rob Bradford
3480e69ff5 vmm: Cache whether io_uring is supported in DeviceManager
Probing for whether the io_uring is supported is time consuming so cache
this value if it is known to reduce the cost for secondary block devices
that are added.

Before:

cloud-hypervisor: 3.988896ms: <vmm> INFO:vmm/src/device_manager.rs:1901 -- Creating virtio-block device: DiskConfig { path: Some("/home/rob/workloads/focal-server-cloudimg-amd64-custom-20210609-0.raw"), readonly: false, direct: false, iommu: false, num_queues: 1, queue_size: 128, vhost_user: false, vhost_socket: None, poll_queue: true, rate_limiter_config: None, id: Some("_disk0"), disable_io_uring: false, pci_segment: 0 }
cloud-hypervisor: 14.129591ms: <vmm> INFO:vmm/src/device_manager.rs:1983 -- Using asynchronous RAW disk file (io_uring)
cloud-hypervisor: 14.159853ms: <vmm> INFO:vmm/src/device_manager.rs:1901 -- Creating virtio-block device: DiskConfig { path: Some("/tmp/disk"), readonly: false, direct: false, iommu: false, num_queues: 1, queue_size: 128, vhost_user: false, vhost_socket: None, poll_queue: true, rate_limiter_config: None, id: Some("_disk1"), disable_io_uring: false, pci_segment: 0 }
cloud-hypervisor: 22.110281ms: <vmm> INFO:vmm/src/device_manager.rs:1983 -- Using asynchronous RAW disk file (io_uring)

After:

cloud-hypervisor: 4.880411ms: <vmm> INFO:vmm/src/device_manager.rs:1916 -- Creating virtio-block device: DiskConfig { path: Some("/home/rob/workloads/focal-server-cloudimg-amd64-custom-20210609-0.raw"), readonly: false, direct: false, iommu: false, num_queues: 1, queue_size: 128, vhost_user: false, vhost_socket: None, poll_queue: true, rate_limiter_config: None, id: Some("_disk0"), disable_io_uring: false, pci_segment: 0 }
cloud-hypervisor: 14.105123ms: <vmm> INFO:vmm/src/device_manager.rs:1998 -- Using asynchronous RAW disk file (io_uring)
cloud-hypervisor: 14.134837ms: <vmm> INFO:vmm/src/device_manager.rs:1916 -- Creating virtio-block device: DiskConfig { path: Some("/tmp/disk"), readonly: false, direct: false, iommu: false, num_queues: 1, queue_size: 128, vhost_user: false, vhost_socket: None, poll_queue: true, rate_limiter_config: None, id: Some("_disk1"), disable_io_uring: false, pci_segment: 0 }
cloud-hypervisor: 14.221869ms: <vmm> INFO:vmm/src/device_manager.rs:1998 -- Using asynchronous RAW disk file (io_uring)

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-12 18:09:55 +00:00
Rob Bradford
d96d98d88e vmm: Port DeviceManager to Aml::append_aml_bytes()
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-08 16:46:30 +00:00
Rob Bradford
def98faf37 vmm, vm-allocator: Introduce an allocator for platform devices
This allocator allocates 64-bit MMIO addresses for use with platform
devices e.g. ACPI control devices and ensures there is no overlap with
PCI address space ranges which can cause issues with PCI device
remapping.

Use this allocator the ACPI platform devices.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
1a5a89508b vmm: Remove segment_id from DeviceNode
With the segment id now encoded in the bdf it is not necessary to have
the separate field for it.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
ae83e3b383 vmm: Use PciBdf throughout in order to remove manual bit manipulation
In particular use the accessor for getting the device id from the bdf.
As a side effect the VIOT table is now segment aware.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
a26ce353d3 vmm: Use the PCI segment allocator for pmem and fs cache allocations
Use the MMIO address space allocator associated with the segment that
the devices are on.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
cd9d1cf8fc pci, virtio-devices, vmm: Allocate PCI 64-bit bars per segment
Since each segment must have a non-overlapping memory range associated
with it the device memory must be equally divided amongst all segments.
A new allocator is used for each segment to ensure that BARs are
allocated from the correct address ranges. This requires changes to
PciDevice::allocate/free_bars to take that allocator and when
reallocating BARs the correct allocator must be identified from the
ranges.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
f71f6da907 vmm: Add pci_segment option to UserDeviceConfig
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
d4f7f42800 vmm: Add pci_segment option to DeviceConfig
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
ca955a47ff vmm: Implement pci_segment options for hotpluggable virtio devices
For all the devices that support being hotplugged (disk, net, pmem, fs
and vsock) add "pci_segment" option and propagate that through to the
addition onto the PCI busses.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
88378d17a2 vmm: Take PCI segment ID into BAR size allocation
Move the decision on whether to use a 64-bit bar up to the DeviceManager
so that it can use both the device type (e.g. block) and the PCI segment
ID to decide what size bar should be used.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
cf1c2bf0e8 vmm: Use the same set of reserved PCI IRQ routes for all segments
Generate a set of 8 IRQs and round-robin distribute those over all the
slots for a bus. This same set of IRQs is then used for all PCI
segments.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
e3d6e222a1 vmm: Add the required number of PCI segments
The platform config may specify a number of PCI segments to use, if this
greater than 1 then we add supplemental PCI segments as well as the
default segment.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
e3c35a3579 vmm: Allow specifying the PCI segment ID when adding virtio PCI device
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
7a4606f800 vmm: Implement ACPI hotplug/unplug handling for PCI segments
For the bus scanning the GED AML code now calls into a PSCN method that
scans all buses. This approach was chosen since it handles the case
correctly where one GED interrupt is services for two hotplugs on
distinct segments.

The PCIU and PCID field values are now determined by the PSEG field that
is uses to select which segment those values should be used for.
Similarly _EJ0 will notify based on the value of _SEG.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
49f19e061b vmm: Use device's segment when removing a device
The segment ID has been stored in the DeviceTree.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
d33d254921 vmm: Remove hardcoded zero PCI segment id
Replace the hardcoded zero PCI segment id when adding devices to the bus
and extend the DeviceTree to hold the PCI segment id.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
b8b0dab1ae vmm: Add segment_id parameter to DeviceManager::add_pci_device
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
080ce9b068 vmm: Populate MCFG table with details of all PCI segments
The MCFG table holds the PCI MMIO config details for all the MMIO PCI
config devices.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
c886d71d29 vmm: Add MMIO & PIO config devices for all PCI segments
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
4f5c179b9b vmm: Construct PCI DSDT data from all segments
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
fbb385834a vmm: Use a vector to store multiple segments
For now this still contains just one segment but is expanding in
preparation for more segments.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Rob Bradford
8b67298ad8 vmm: Move PCI bus DSDT data onto PciSegment
This commit moves the code that generates the DSDT data for the PCI bus
into PciSegment making no functional changes to the generated AML.

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-11-02 16:55:42 +00:00
Sebastien Boeuf
0249e8641a Move Cloud Hypervisor to virtio-queue crate
Relying on the vm-virtio/virtio-queue crate from rust-vmm which has been
copied inside the Cloud Hypervisor tree, the entire codebase is moved to
the new definition of a Queue and other related structures.

The reason for this move is to follow the upstream until we get some
agreement for the patches that we need on top of that to make it
properly work with Cloud Hypervisor.

Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
2021-10-22 11:38:55 +02:00
Rob Bradford
2cccdc5ddd vmm: Naturally align PCI BARs on relocation
When allocating PCI MMIO BARs they should always be naturally aligned
(i.e. aligned to the size of the BAR itself.)

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-10-15 14:54:18 -07:00
Rob Bradford
c25bd447a1 vmm: Ensure that allocate_bars() is called before mmio_regions()
The allocate_bars method has a side effect which collates the BARs used
for the device and stores them internally. Ensure that any use of this
internal state is after the state is created otherwise no MMIO regions
will be seen and so none will be mapped.

Fixes: #3237

Signed-off-by: Rob Bradford <robert.bradford@intel.com>
2021-10-14 10:14:33 -07:00