A simpe getopt-based argument parser is added for the /usr/sbin/bhyve command,
loosely based on its argument parser, which reads the following from the bhyve
command line string:
* vm name
* number of vcpus
* memory size
* the time offset (UTC or localtime)
* features:
* acpi
* ioapic: While this flag is deprecated in FreeBSD r257423, keep checking for
it for backwards compatibiility.
* the domain UUID; if not explicitely given, one will be generated.
* lpc devices: for now only the com1 and com2 are supported. It is required for
these to be /dev/nmdm[\d+][AB], and the slave devices are automatically
inferred from these to be the corresponding end of the virtual null-modem
cable: /dev/nmdm<N>A <-> /dev/nmdm<N>B
* PCI devices:
* Disks: these are numbered in the order they are found, for virtio and ahci
disks separately. The destination is set to sdX or vdX with X='a'+index;
therefore only 'z'-'a' disks are supported.
Disks are considered to be block devices if the path
starts with /dev, otherwise they are considered to be files.
* Networks: only tap devices are supported. Since it isn't possible to tell
the type of the network, VIR_DOMAIN_NET_TYPE_ETHERNET is assumed, since it
is the most generic. If no mac is specified, one will be generated.
Signed-off-by: Fabian Freyer <fabian.freyer@physik.tu-berlin.de>
First, remove escaped newlines and split up the string into an argv-list for
the bhyve and loader commands, respectively. This is done by iterating over the
string splitting it by newlines, and then re-iterating over each line,
splitting it by spaces.
Since this code reuses part of the code of qemu_parse_command.c
(in bhyveCommandLine2argv), add the appropriate copyright notices.
Signed-off-by: Fabian Freyer <fabian.freyer@physik.tu-berlin.de>
In preparation for moving all the CPU related APIs out of
the nodeinfo file, give them a virHostCPU name prefix.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
In preparation for moving all the memory related APIs out of
the nodeinfo file, give them a virHostMem name prefix.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Nearly all the methods in the nodeinfo file are given a
'const char *sysfs_prefix' parameter to override the
default sysfs path (/sys/devices/system). Every single
caller passes in NULL for this, except one use in the
unit tests. Furthermore this parameter is totally
Linux-specific, when the APIs are intended to be cross
platform portable.
This removes the sysfs_prefix parameter and instead gives
a new method linuxNodeInfoSetSysFSSystemPath for use by
the test suite.
For two of the methods this hardcodes use of the constant
SYSFS_SYSTEM_PATH, since the test suite does not need to
override the path for thos methods.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
The virConnectOpenInternal method opens the libvirt client
config file and uses it to resolve things like URI aliases.
There may be driver specific things that are useful to
store in the config file too, so rather than have them
re-parse the same file, pass the virConfPtr down to the
drivers.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Rather than only assigning a PCI address when no address is given at
all, also do it when the config says that the address type is 'pci',
but it gives no address.
Bhyve supports ACPI shutdown by issuing SIGTERM signal to a bhyve
process.
Add the bhyveDomainShutdown() function and virBhyveProcessShutdown()
helper function that just sends SIGTERM to VM's bhyve process. If
a guest supports ACPI shutdown then process will be terminated and
this event will be noticed by the bhyve monitor code that will handle
setting proper status and clean up VM's resources by calling
virBhyveProcessStop().
Current implementation of domainDestroy for bhyve calls
virProcessKillPainfully() for the bhyve process and then
executes "bhyvectl --destroy".
This is wrong for two reasons:
* bhyvectl --destroy alone is sufficient because it terminates
the process
* virProcessKillPainfully() first sends SIGTERM and after few
attempts sends SIGKILL. As SIGTERM triggers ACPI shutdown that
we're not interested in, it creates an unwanted side effect in
domainDestroy.
Also, destroy monitor only after "bhyvectl --destroy" command succeeded
to avoid a case when the command fails and domain remains running, but
not being monitored anymore.
We had both and the only difference was that the latter also included
information about multifunction setting. The problem with that was that
we couldn't use functions made for only one of the structs (e.g.
parsing). To consolidate those two structs, use the one in virpci.h,
include that in domain_conf.h and add the multifunction member in it.
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
The flags used to determine which devices could be plugged into which
controllers were quite confusing, as they tried to create classes of
connections, then put particular devices into possibly multiple
classes, while sometimes setting multiple flags for the controllers
themselves. The attempt to have a single flag indicate, e.g. that a
root-port or a switch-downstream-port could connect was not only
confusing, it was leading to a situation where it would be impossible
to specify exactly the right combinations for a new controller.
The solution is for the VIR_PCI_CONNECT_TYPE_* flags to have a 1:1
correspondence with each type of PCI controller, plus a flag for a PCI
endpoint device and another for a PCIe endpoint device (the only
exception to this is that pci-bridge and pcie-expander-bus controllers
have their upstream connection classified as
VIR_PCI_CONNECT_TYPE_PCI_DEVICE since they can be plugged into
*exactly* the same ports as any endpoint device). Each device then
has a single flag for connect type (plus the HOTPLUG flag if that
device can e hotplugged), and each controller sets the CONNECT bits
for all controllers that can be plugged into it, as well as for either
type of endpoint device that can be plugged in (and the HOTPLUG flag
if it can accept hotplugged devices).
With this change, it is *slightly* easier to understand the matching
of connections (as long as you remember that the flag for a
device/upstream-facing connection of a controller is the same as that
device's type, while the flags for a controller's downstream
connections is the OR of all device types that can be plugged into
that controller). More importantly, it will be possible to correctly
specify what can be plugged into a pcie-switch-expander-bus, when
support for it is added.
Introduce a helper to check supported device and domain config and move
the memory hotplug checks to it.
The advantage of this approach is that by default all new features are
considered unsupported by all hypervisors unless specifically changed
rather than the previous approach where every hypervisor would need to
declare that a given feature is unsupported.
Syntax-check fails with:
cppi: src/bhyve/bhyve_driver.h: line 26: not properly indented
cppi: src/bhyve/bhyve_driver.h: line 27: not properly indented
maint.mk: incorrect preprocessor indentation
Fix by properly indenting '#include's.
Pushed as trivial.
After 1036ddadb2 we use bhyveDriverGetCapabilities from other
sources too, not only from bhyve_driver.c. However, the function
was static so not properly expose to other files. In order to
expose it, we need to move couple of #include-s too.
Then, there has been a copy paste error in
virBhyveProcessReconnect: s/privconn/data->driver/.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
The virDomainObjFormat and virDomainSaveStatus methods
both call into virDomainDefFormat, so should be providing
a non-NULL virCapsPtr instance.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
virDomainSaveConfig calls virDomainDefFormat which was setting the caps
to NULL, thus keeping the old behaviour (i.e. not looking at
netprefix). This patch adds the virCapsPtr to the function and allows
the configuration to be saved and skipping interface names that were
registered with virCapabilitiesSetNetPrefix().
Signed-off-by: Joao Martins <joao.m.martins@oracle.com>
And use the newly added caps->host.netprefix (if it exists) for
interface names that match the autogenerated target names.
Signed-off-by: Joao Martins <joao.m.martins@oracle.com>
Make bhyveload respect boot order as specified by os.boot section of the
domain XML or by "boot order" for specific devices. As bhyve does not
support a real boot order specification right now, it's just about
choosing a single device to boot from.
Our domain_conf.* files are big enough. Not only they contain XML
parsing code, but they served as a storage of all functions whose
name is virDomain prefixed. This is just wrong as it gathers not
related functions (and modules) into one big file which is then
harder to maintain. Split virDomainObjList module into a separate
file called virdomainobjlist.[ch].
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Current monitor code overrides domain object's privateData, e.g.
in virBhyveProcessStart():
vm->privateData = bhyveMonitorOpen(vm, driver);
where bhyveMonitorPtr() returns bhyveMonitorPtr.
This is not right thing to do, so make bhyveMonitorPtr
a part of the bhyveDomainObjPrivate struct and change related code
accordingly.
We have macros for both positive and negative string matching.
Therefore there is no need to use !STREQ or !STRNEQ. At the same
time as we are dropping this, new syntax-check rule is
introduced to make sure we won't introduce it again.
Signed-off-by: Ishmanpreet Kaur Khera <khera.ishman@gmail.com>
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=871452
So, you want to create a domain from XML. The domain already
exists in libvirt's database of domains. It's okay, because name
and UUID matches. However, on domain startup, internal
representation of the domain is overwritten with your XML even
though we claim that the XML you've provided is a transient one.
The bug is to be found across nearly all the drivers.
Le sigh.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
Bhyve as of r279225 (FreeBSD -CURRENT) or r284894 (FreeBSD 10-STABLE)
supports using UTC time offset via the '-u' argument to bhyve(8). By
default it's still using localtime.
Make the bhyve driver use UTC clock if it's requested by specifying
<clock offset='utc'> in domain XML and if the bhyve(8) binary supports
the '-u' flag.
Build with gcc 4.8 fails with:
bhyve/bhyve_monitor.c: In function 'bhyveMonitorIO':
bhyve/bhyve_monitor.c:51:18: error: missing initializer for field 'tv_sec' of 'const struct timespec' [-Werror=missing-field-initializers]
const struct timespec zerowait = {};
Explicitly initialize zerowait to fix the build.
Every domain that grabs a domain object to work over should
reference it to make sure it won't disappear meanwhile.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
This needs to specified in way too many places for a simple validation
check. The ostype/arch/virttype validation checks later in
DomainDefParseXML should catch most of the cases that this was covering.
This patch adds code that parses and formats configuration for memory
devices.
A simple configuration would be:
<memory model='dimm'>
<target>
<size unit='KiB'>524287</size>
<node>0</node>
</target>
</memory>
A complete configuration of a memory device:
<memory model='dimm'>
<source>
<pagesize unit='KiB'>4096</pagesize>
<nodemask>1-3</nodemask>
</source>
<target>
<size unit='KiB'>524287</size>
<node>1</node>
</target>
</memory>
This patch preemptively forbids use of the <memory> device in individual
drivers so the users are warned right away that the device is not
supported.