Add support extracting the sections out for a TDVF file which can be
then used to load the TDVF and TD HOB data into their appropriate
locations.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Add the skeleton of the "tdx" feature with a module ready inside the
arch crate to store implementation details.
TEST=cargo build --features="tdx"
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The interrupt tests were not being run as they were erroneously under a
feature guard that does not exist in arch.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
If the function can never return an error this is now a clippy failure:
error: this function's return value is unnecessarily wrapped by `Result`
--> virtio-devices/src/watchdog.rs:215:5
|
215 | / fn set_state(&mut self, state: &WatchdogState) -> io::Result<()> {
216 | | self.common.avail_features = state.avail_features;
217 | | self.common.acked_features = state.acked_features;
218 | | // When restoring enable the watchdog if it was previously enabled. We reset the timer
... |
223 | | Ok(())
224 | | }
| |_____^
|
= help: for further information visit https://rust-lang.github.io/rust-clippy/master/index.html#unnecessary_wraps
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
This reflects that it generates CPUID state used across all vCPUs.
Further ensure that errors from this function get correctly propagated.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Move the code for populating the CPUID with KVM HyperV emulation details from
the per-vCPU CPUID handling code to the shared CPUID handling code.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Move the code for populating the CPUID with details of the CPU
identification from the per-vCPU CPUID handling code to the shared CPUID
handling code.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Move the code for populating the CPUID with details of the maximum
address space from the per-vCPU CPUID handling code to the shared CPUID
handling code.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
We must explicitly mark these values as u8 as the function that consumes
them takes a T and needs to use the specific width.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
We will need the GDT API for the hypervisor's x86 instruction
emulator implementation, it's better if the arch crate depends on the
hypervisor one rather than the other way around.
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
If the user specified a maximum physical bits value through the
`max_phys_bits` option from `--cpus` parameter, the guest CPUID
will be patched accordingly to ensure the guest will find the
right amount of physical bits.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In order to speed up the Linux boot (so as to avoid it having to scan a
large number of pages) place the MP table directly after the SMBIOS
table if there is sufficient room. The start address of the SMBIOS table
is one of the three (and the largest) location that the MP table can
also be located at.
Before:
[ 0.000399] x86/PAT: Configuration [0-7]: WB WC UC- UC WB WP UC- WT
[ 0.014945] check: Scanning 1 areas for low memory corruption
After:
[ 0.000284] x86/PAT: Configuration [0-7]: WB WC UC- UC WB WP UC- WT
[ 0.000421] found SMP MP-table at [mem 0x000f0090-0x000f009f]
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Inject CPUID leaves for advertising KVM HyperV support when the
"kvm_hyperv" toggle is enabled. Currently we only enable a selection of
features required to boot.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
SGX expects the EPC region to be reported as "reserved" from the e820
table. This patch adds a new entry to the table if SGX is enabled.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The support for SGX is exposed to the guest through CPUID 0x12. KVM
passes static subleaves 0 and 1 from the host to the guest, without
needing any modification from the VMM itself.
But SGX also relies on dynamic subleaves 2 through N, used for
describing each EPC section. This is not handled by KVM, which means
the VMM is in charge of setting each subleaf starting from index 2
up to index N, depending on the number of EPC sections.
These subleaves 2 through N are not listed as part of the supported
CPUID entries from KVM. But it's important to set them as long as index
0 and 1 are present and indicate that SGX is supported.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Based on the presence of one or multiple SGX EPC sections from the VM
configuration, the MemoryManager will allocate a contiguous block of
guest address space to hold the entire EPC region. Within this EPC
region, each EPC section is memory mapped.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
The OVMF firmware loops around looking for an entry marking the end of
the table. Without this entry processing the tables is an infinite loop.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Taken from crosvm: 44336b913126d73f9f8d6854f57aac92b5db809e and adapted
for Cloud Hypervisor.
This is basic and incomplete support but Linux correctly finds the DMI
data based on this:
root@clr-c6ed47bc1c9d473d9a3a8bddc50ee4cb ~ # dmesg | grep -i dmi
[ 0.000000] DMI: Cloud Hypervisor cloud-hypervisor, BIOS 0
root@clr-c6ed47bc1c9d473d9a3a8bddc50ee4cb ~ # dmesg | grep -i smbio
[ 0.000000] SMBIOS 3.2.0 present.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Start moving the vmm, arch and pci crates to being hypervisor agnostic
by using the hypervisor trait and abstractions. This is not a complete
switch and there are still some remaining KVM dependencies.
Signed-off-by: Muminul Islam <muislam@microsoft.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
There are two CPUID leaves for handling CPU topology, 0xb and 0x1f. The
difference between the two is that the 0x1f leaf (Extended Topology
Leaf) supports exposing multiple die packages.
Fixes: #1284
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The extended topology leaf (0x1f) also needs to have the APIC ID (which
is the KVM cpu ID) set. This mirrors the APIC ID set on the 0xb topology
leaf
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
For correctness, when the CPUID supports the LA57 feature, the VMM sets
the CR4.LA57 register, which means a fifth level of page table might be
needed. Even if it's not needed because the kernel should not use
addresses over 1GiB, it's better to define this new level anyway.
This patch only applies to the Linux boot codepath, which means it
affects both vmlinux without PVH and bzImage binaries. The bzImage
does not need this since the page tables and CR4 registers are set in
the decompression code from the kernel.
And for vmlinux with PVH, if we follow the PVH specification, the kernel
must be responsible for setting things up, but the implementation is
missing. This means for now that PVH does not support LA57 with 5 levels
of paging.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
In case the host CPU exposes the support for LA57 feature through its
cpuid, the CR4.LA57 bit is enabled accordingly.
Signed-off-by: Sebastien Boeuf <sebastien.boeuf@intel.com>
Now the flow of both architectures are aligned to:
1. load kernel
2. create VCPU's
3. configure system
4. start VCPU's
Signed-off-by: Michael Zhao <michael.zhao@arm.com>
This is a preparing commit to build and test CH on AArch64. All building
issues were fixed, but no functionality was introduced.
For X86, the logic of code was not changed at all.
For ARM, the architecture specific part is still empty. And we applied
some tricks to workaround lint warnings. But such code will be replaced
later by other commits with real functionality.
Signed-off-by: Michael Zhao <michael.zhao@arm.com>
Use the ACPI feature to control whether to build the mptable. This is
necessary as the mptable and ACPI RSDP table can easily overwrite each
other leading to it failing to boot.
TEST=Compile with default features and see that --cpus boot=48 now
works, try with --no-default-features --features "pci" and observe the
--cpus boot=48 also continues to work.
Fixes: #1132
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
The setup_mptables() call which is not used on ACPI builds has a side
effect of testing whether there was enough RAM which one of the unit
tests was relying on. Add a similar check for the RSDP address.
Signed-off-by: Rob Bradford <robert.bradford@intel.com>
Fill and write to guest memory the necessary boot module
structure to allow a guest using the PVH boot protocol
to load an initramfs image.
Signed-off-by: Alejandro Jimenez <alejandro.j.jimenez@oracle.com>
Commit 2adddce2 reorganized the crate for a cleaner multi architecture
(x86_64 and aarch64) support.
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
* load the initramfs File into the guest memory, aligned to page size
* finally setup the initramfs address and its size into the boot params
(in configure_64bit_boot)
Signed-off-by: Damjan Georgievski <gdamjan@gmail.com>