Management tools may want to check whether the threshold is still set if
they missed an event. Add the data to the bulk stats API where they can
also query the current backing size at the same time.
When using thin provisioning, management tools need to resize the disk
in certain cases. To avoid having them to poll disk usage introduce an
event which will be fired when a given offset of the storage is written
by the hypervisor. Together with the API which will be added later, it
will allow registering thresholds for given storage backing volumes and
this event will then notify management if the threshold is exceeded.
Add bhyve support to virt-host-validate(1). It checks for the
essential kernel modules to be available so that user can actually
start VMs, have networking and console access.
It uses the kldnext(2)/kldstat(2) routines to retrieve modules list.
As bhyve is only available on FreeBSD and these routines were available
long before bhyve appeared, not adding any specific configure checks
for that.
Also, update tools/Makefile.am to add
virt-host-validate-$driver.[hc] to the build only if the
appropriate driver is enabled.
In GCC 7 there is a new warning triggered when a switch
case has a conditional statement (eg if ... else...) and
some of the code paths fallthrough to the next switch
statement. e.g.
conf/domain_conf.c: In function 'virDomainChrEquals':
conf/domain_conf.c:14926:12: error: this statement may fall through [-Werror=implicit-fallthrough=]
if (src->targetTypeAttr != tgt->targetTypeAttr)
^
conf/domain_conf.c:14928:5: note: here
case VIR_DOMAIN_CHR_DEVICE_TYPE_CONSOLE:
^~~~
conf/domain_conf.c: In function 'virDomainChrDefFormat':
conf/domain_conf.c:22143:12: error: this statement may fall through [-Werror=implicit-fallthrough=]
if (def->targetTypeAttr) {
^
conf/domain_conf.c:22151:5: note: here
default:
^~~~~~~
GCC introduced a __attribute__((fallthrough)) to let you
indicate that this is intentionale behaviour rather than
a bug.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Alter the formatting of each line to not give the appearance of
one long run-on sentence and to be consistent between the various
elements of collected/displayed data. The formatting should fit
within the 80 character display. This removes the need for commas
at the end of each line.
After 7f1bdec5fa our nodedev driver is capable of
determining DRM devices (DRM stands for Direct Render Manager not
Digital rights management). There is still one bit missing
though: virConnectListAllNodeDevices() is capable of listing
either all devices or just those with specified capability. Well,
DRM capability is missing there.
Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
All options started with underscores, but we switched them to dashes
later on, making the style consistent. The latest addition, however,
did not respect that, so let's change that as well. It is tempting to
just change the name instead of adding alias, especially since nobody
ever used it, which we know thanks to the fact that it didn't work.
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
Function vshCommandOptStringReq() returns -1 on error and 0 on
success. The code, however, used the 'group_name' variable only if it
returned 1 (never).
Signed-off-by: Martin Kletzander <mkletzan@redhat.com>
As LIBVIRT_DEBUG=4 logs only error messages and there
are no levels above it, adjusting the description in
the man page accordingly.
Signed-off-by: Nitesh Konkar <nitkon12@linux.vnet.ibm.com>
This commit is similar to commit 0977ada8.The virsh manpage
lists options --uuid and --name as mutually exclusive if
option --details is specified when actually the option
--details is mutually exclusive and can't go with options
--uuid and/or --name. This patch rewords the virsh manpage
to state the correct meaning.
Signed-off-by: Nitesh Konkar <nitkon12@linux.vnet.ibm.com>
Added general definitions for vstorage pool backend including
the build options to add --with-storage-vstorage checking.
In order to use vstorage as a backend for a storage pool
vstorage tools (vstorage and vstorage-mount) need to be installed.
Signed-off-by: Olga Krishtal <okrishtal@virtuozzo.com>
The recent deprecation in glibc (commit b76e065991ec) means the
module will fail to build entirely:
nss/libvirt_nss.c: In function '_nss_libvirt_gethostbyname_r':
nss/libvirt_nss.c:363:13: error: RES_USE_INET6 is deprecated [-Werror]
int af = ((_res.options & RES_USE_INET6) ? AF_INET6 : AF_INET);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~
This resolver option was removed shortly after being introduced,
and application using it are already broken anyway.
This patch will allow --uuid and --name in one cmd.
The pool's UUID and name will be printed side by side.
Signed-off-by: Chen Hanxiao <chenhanxiao@gmail.com>
By default, pool-info will convert sizes to human friendly units.
This patch will introduce option [--bytes].
If specified, the raw sizes will be in the output.
Signed-off-by: Chen Hanxiao <chenhanxiao@gmail.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1373711
Add support and documentation for the [NO_]OVERWRITE flags for the
logical backend.
Update virsh.pod with a description of the process for usage of
the flags and building of the pool's volume group.
Signed-off-by: John Ferlan <jferlan@redhat.com>
Rather than have the Disk code having to use PARTED to determine if
there's something on the device, let's use the virStorageBackendDeviceProbe.
and only fallback to the PARTED probing if the BLKID code isn't built in.
This will also provide a mechanism for the other current caller (File
System Backend) to utilize a PARTED parsing algorithm in the event that
BLKID isn't built in to at least see if *something* exists on the disk
before blindly trying to use. The PARTED error checking will not find
file system types, but if there is a partition table set on the device,
it will at least cause a failure.
Move virStorageBackendDiskValidLabel and virStorageBackendDiskFindLabel
to storage_backend and rename/rework the code to fit the new model.
Update the virsh.pod description to provide a more generic description
of the process since we could now use either blkid or parted to find
data on the target device.
Signed-off-by: John Ferlan <jferlan@redhat.com>
https://bugzilla.redhat.com/show_bug.cgi?id=1363586
Commit id '27758859' introduced the "NO_OVERWRITE" flag check for
file system backends; however, the implementation, documentation,
and algorithm was inconsistent. For the "flag" description for the
API the flag was described as "Do not overwrite existing pool";
however, within the storage backend code the flag is described
as "it probes to determine if filesystem already exists on the
target device, renurning an error if exists".
The code itself was implemented using the paradigm to set up the
superblock probe by creating a filter that would cause the code
to only search for the provided format type. If that type wasn't
found, then the algorithm would return success allowing the caller
to format the device. If the format type already existed on the
device, then the code would fail indicating that the a filesystem
of the same type existed on the device.
The result is that if someone had a file system of one type on the
device, it was possible to overwrite it if a different format type
was specified in updated XML effectively trashing whatever was on
the device already.
This patch alters what NO_OVERWRITE does for a file system backend
to be more realistic and consistent with what should be expected when
the caller requests to not overwrite the data on the disk.
Rather than filter results based on the expected format type, the
code will allow success/failure be determined solely on whether the
blkid_do_probe calls finds some known format on the device. This
adjustment also allows removal of the virStoragePoolProbeResult
enum that was under utilized.
If it does find a formatted file system different errors will be
generated indicating a file system of a specific type already exists
or a file system of some other type already exists.
In the original virsh support commit id 'ddcd5674', the description
for '--no-overwrite' within the 'pool-build' command help output
has an ambiguous "of this type" included in the short description.
Compared to the longer description within the "Build a given pool."
section of the virsh.pod file it's more apparent that the meaning
of this flag would cause failure if a probe of the target already
has a filesystem.
So this patch also modifies the short description to just be the
antecedent of the 'overwrite' flag, which matches the API description.
This patch also modifies the grammar in virsh.pod for no-overwrite
as well as reworking the paragraph formats to make it easier to read.
Signed-off-by: John Ferlan <jferlan@redhat.com>
The virsh manpage lists "shutdown" and "dying" as two of the possible
domain states that could be listed in the output of the "virsh list"
command. However, a domain that is being shutdown will be listed as
"in shutdown", and the "dying" state doesn't even exist (and never
has, as far as I can tell from looking through git history - it was
shown in the original import of the virsh.pod file in 2006; there was
no VIR_DOMAIN_DYING state then, there wasn't one when those lines of
virsh.pod were tweaked in 2008, and there still isn't one
today. Apparently it was just something that sounded like a good idea
to someone at some time, but was never implemented...)
Resolves: https://bugzilla.redhat.com/1408778
This patch adds support and documentation for
a generalized hardware cache event called cache_l1d
perf event.
Signed-off-by: Nitesh Konkar <nitkon12@linux.vnet.ibm.com>
The virsh manpage lists options --uuid and --name as
mutually exclusive along option --table when actually
the option --table is mutually exclusive and can't go
with options --uuid and/or --name. This patch rewords the
virsh manpage to state the correct meaning.
Signed-off-by: Nitesh Konkar <nitkon12@linux.vnet.ibm.com>
When setting perf events, the enabled/disabled perf events are not
listed. Since we know which events were changed it's possible to
print out the values on successful set, such as :
virsh perf Domain --enable instructions --disable cache_misses
instructions : enabled
cache_misses : disabled
Created a helper to print the messages - use the vshPrintExtra to
adhere to the --quiet|-q option being set by some script. This will
cause the get code to print nothing, but will return success/failure.
Signed-off-by: Nitesh Konkar <nitkon12@linux.vnet.ibm.com>
When changing the metadata via virDomainSetMetadata, we now
emit an event to notify the app of changes. This is useful
when co-ordinating different applications read/write of
custom metadata.
Signed-off-by: Daniel P. Berrange <berrange@redhat.com>
Add a new qualifier '--physical' to the 'vol-info' command in order to
dispaly the physical size of the volume. The size can differ from the
allocation value depending on the volume file time. In particular, qcow2
volumes will have a physical value larger than allocation. This also occurs
for sparse files, although for those the capacity is the largest size;
whereas, for qcow2 capacity is the logical size.
Signed-off-by: John Ferlan <jferlan@redhat.com>
Finally, now that all APIs have been introduced, wire them up to virt-admin
and introduce daemon-log-outputs and daemon-log-filters commands.
Signed-off-by: Erik Skultety <eskultet@redhat.com>